메뉴 건너뛰기




Volumn 4, Issue , 2005, Pages

A portable near infrared spectroscopy system for bedside monitoring of newborn brain

Author keywords

[No Author keywords available]

Indexed keywords

BEDSIDE MONITORING; BRAIN INJURY; NEONATAL INTENSIVE CARE UNITS;

EID: 26844481098     PISSN: 1475925X     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/1475-925X-4-29     Document Type: Article
Times cited : (138)

References (23)
  • 1
    • 0030843420 scopus 로고    scopus 로고
    • Non-invasive optical spectroscopy and imaging of human brain function
    • Villringer A, Chance B: Non-invasive optical spectroscopy and imaging of human brain function. Trends in Neurosciences 1997, 20(10):435-42.
    • (1997) Trends in Neurosciences , vol.20 , Issue.10 , pp. 435-442
    • Villringer, A.1    Chance, B.2
  • 2
    • 0036790009 scopus 로고    scopus 로고
    • Non-invasive neuroimaging using near-infrared light
    • Strangman G, Boas DA, Sutton JP: Non-invasive neuroimaging using near-infrared light. Biological Psychiatry 2002, 52(7):679-93.
    • (2002) Biological Psychiatry , vol.52 , Issue.7 , pp. 679-693
    • Strangman, G.1    Boas, D.A.2    Sutton, J.P.3
  • 3
    • 1842482496 scopus 로고    scopus 로고
    • Neonatal Intensive Care: Obvious Yet Difficult Area for Cerebral Near Infrared Spectroscopy
    • Skov L, Brun NC, Greisen G: Neonatal Intensive Care: Obvious Yet Difficult Area for Cerebral Near Infrared Spectroscopy. Journal of Biomedical Optics 1997, 2(1):7-14.
    • (1997) Journal of Biomedical Optics , vol.2 , Issue.1 , pp. 7-14
    • Skov, L.1    Brun, N.C.2    Greisen, G.3
  • 4
    • 0023019602 scopus 로고
    • Quantification of cerebral oxygenation and haemodynamics in sick newborn infants by near infrared spectrophotometry
    • Wyatt JS, Cope M, Delpy DT, Wray S, Reynolds EOR: Quantification of cerebral oxygenation and haemodynamics in sick newborn infants by near infrared spectrophotometry. Lancet 1986, 8515:1063-1066.
    • (1986) Lancet , vol.8515 , pp. 1063-1066
    • Wyatt, J.S.1    Cope, M.2    Delpy, D.T.3    Wray, S.4    Reynolds, E.O.R.5
  • 6
    • 0000743021 scopus 로고    scopus 로고
    • Design and evaluation of a continuous-wave diffuse optical tomography system
    • Siegel AM, Marota JJA, Boas DA: Design and evaluation of a continuous-wave diffuse optical tomography system. Optics Express 1999, 4:287-298.
    • (1999) Optics Express , vol.4 , pp. 287-298
    • Siegel, A.M.1    Marota, J.J.A.2    Boas, D.A.3
  • 8
    • 0028800303 scopus 로고
    • Near-infrared spectroscopy for the in vivo study of cerebral hemodynamics and oxygenation
    • du Plessis AJ: Near-infrared spectroscopy for the in vivo study of cerebral hemodynamics and oxygenation. Current Opinion in Pediatrics 1995, 7:632-639.
    • (1995) Current Opinion in Pediatrics , vol.7 , pp. 632-639
    • du Plessis, A.J.1
  • 10
    • 0033043874 scopus 로고    scopus 로고
    • Cerebral blood oxygenation changes induced by auditory stimulation in newborn infants measured by near infrared spectroscopy
    • Sakatani K, Chen S, Lichty W, Zuo H, Wang Y: Cerebral blood oxygenation changes induced by auditory stimulation in newborn infants measured by near infrared spectroscopy. Early Human Development 1999, 55:229-236.
    • (1999) Early Human Development , vol.55 , pp. 229-236
    • Sakatani, K.1    Chen, S.2    Lichty, W.3    Zuo, H.4    Wang, Y.5
  • 12
    • 2142686108 scopus 로고    scopus 로고
    • Hemodynamic responses to visual stimulation in occipital and frontal cortex of newborn infants: A near-infrared optical topography study
    • Taga G, Asakawa K, Hirasawa K, Konishi Y: Hemodynamic responses to visual stimulation in occipital and frontal cortex of newborn infants: a near-infrared optical topography study. Early Hum Dev 2003, 75(Suppl):S203-10.
    • (2003) Early Hum. Dev. , vol.75 , Issue.SUPPL.
    • Taga, G.1    Asakawa, K.2    Hirasawa, K.3    Konishi, Y.4
  • 14
    • 0024017466 scopus 로고    scopus 로고
    • System for long-term measurement of cerebral blood flow and tissue oxygenation on newborn infants by infrared transillumination
    • Cope M, Delpy DT: System for long-term measurement of cerebral blood flow and tissue oxygenation on newborn infants by infrared transillumination. Med Biol Eng Comput 1998, 26:289-294.
    • (1998) Med. Biol. Eng. Comput. , vol.26 , pp. 289-294
    • Cope, M.1    Delpy, D.T.2
  • 15
    • 0003926238 scopus 로고
    • The Development of a Near-Infrared Spectroscopy System and Its Application for Noninvasive Monitoring of Cerebral Blood and Tissue Oxygenation in the Newborn Infant
    • University College London, London
    • Cope M: The Development of a Near-Infrared Spectroscopy System and Its Application for Noninvasive Monitoring of Cerebral Blood and Tissue Oxygenation in the Newborn Infant. University College London, London; 1991.
    • (1991)
    • Cope, M.1
  • 16
    • 0010649489 scopus 로고    scopus 로고
    • "Noninvasive Imaging of Cerebral Activation with Diffuse Optical Tomography"
    • Edited by: Frostig RD. Boca Raton: CRC Press
    • Boas DA, Franceschini MA, Dunn AK, Strangman G: "Noninvasive Imaging of Cerebral Activation with Diffuse Optical Tomography." In In Vivo Optical Imaging of Brain Function Edited by: Frostig RD. Boca Raton: CRC Press; 2002:193-221.
    • (2002) In Vivo Optical Imaging of Brain Function , pp. 193-221
    • Boas, D.A.1    Franceschini, M.A.2    Dunn, A.K.3    Strangman, G.4
  • 17
    • 0023865632 scopus 로고
    • Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation
    • Wray S, Cope M, Delpy DT, Wyatt JS, Reynolds EO: Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation. Biochim Biophys Acta 1988, 933(1):184-92.
    • (1988) Biochim. Biophys. Acta , vol.933 , Issue.1 , pp. 184-192
    • Wray, S.1    Cope, M.2    Delpy, D.T.3    Wyatt, J.S.4    Reynolds, E.O.5
  • 18
    • 0027067074 scopus 로고
    • Experimentally measured optical pathlengths for the adult's head, calf and forearm and the head of the newborn infant as a function of interoptode spacing
    • Van der Zee P, Cope M, Arridge SR, et al.: Experimentally measured optical pathlengths for the adult's head, calf and forearm and the head of the newborn infant as a function of interoptode spacing. Adv Exp Med Biol 1992, 316:143-153.
    • (1992) Adv. Exp. Med. Biol. , vol.316 , pp. 143-153
    • Van der Zee, P.1    Cope, M.2    Arridge, S.R.3
  • 19
    • 84962306380 scopus 로고    scopus 로고
    • Pediatric Evaluation and Monitoring Considerations
    • Edited by: Darovic GO. Philadelphia, PA: W.B.Saunders
    • Hazinski MF: Pediatric Evaluation and Monitoring Considerations. In Hemodynamic Monitoring: Invasive and Noninvasive Clinical Application Edited by: Darovic GO. Philadelphia, PA: W.B.Saunders; 2002:471-514.
    • (2002) Hemodynamic Monitoring: Invasive and Noninvasive Clinical Application , pp. 471-514
    • Hazinski, M.F.1
  • 21
    • 0034968318 scopus 로고    scopus 로고
    • Wavelength dependence of the precision of noninvasive optical measurement of oxydeoxy-, and total-hemoglobin concentration
    • Yamashita Y, Maki A, Koizumi H: Wavelength dependence of the precision of noninvasive optical measurement of oxydeoxy-, and total-hemoglobin concentration. Med Phys 2001, 28(6):1108-14.
    • (2001) Med. Phys. , vol.28 , Issue.6 , pp. 1108-1114
    • Yamashita, Y.1    Maki, A.2    Koizumi, H.3
  • 22
    • 3042552197 scopus 로고    scopus 로고
    • Safety assessment of near infrared light emitting diodes for diffuse optical measurements
    • Bozkurt A, Onaral B: Safety assessment of near infrared light emitting diodes for diffuse optical measurements. BioMedical Engineering OnLine 2004, 3:9.
    • (2004) BioMedical Engineering OnLine , vol.3 , pp. 9
    • Bozkurt, A.1    Onaral, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.