메뉴 건너뛰기




Volumn 50, Issue 5, 2005, Pages 494-498

Smooth or textured implants: What to select?;Prothèses lisses ou texturées: Que choisir?

Author keywords

Augmentation; Breast; Capsular contracture; Implants; Smooth; Textured

Indexed keywords

SILICONE;

EID: 26844470387     PISSN: 02941260     EISSN: 1768319X     Source Type: Journal    
DOI: 10.1016/j.anplas.2005.07.002     Document Type: Article
Times cited : (2)

References (25)
  • 1
    • 0031035784 scopus 로고    scopus 로고
    • Textured or smooth implants for breast augmentation? Three-year follow-up of a prospective randomised controlled trial
    • C.M. Malata, L.F.D.J. Coleman, I.T.H. Foo, and D.T. Sharpe Textured or smooth implants for breast augmentation? Three-year follow-up of a prospective randomised controlled trial Br. J. Plast. Surg. 50 1997 99 105
    • (1997) Br. J. Plast. Surg. , vol.50 , pp. 99-105
    • Malata, C.M.1    Coleman, L.F.D.J.2    Foo, I.T.H.3    Sharpe, D.T.4
  • 2
    • 0034943631 scopus 로고    scopus 로고
    • Breast augmentation with round, smooth saline or gel implants. Augmentation mammaplasty
    • L.F. Elliott Breast augmentation with round, smooth saline or gel implants. Augmentation mammaplasty Ann. Plast. Surg. 28 2001 523 529
    • (2001) Ann. Plast. Surg. , vol.28 , pp. 523-529
    • Elliott, L.F.1
  • 4
    • 0032982883 scopus 로고    scopus 로고
    • A review of the literature on the etiology of capsular contracture and a pilot study to determine the outcome of capsular contracture interventions
    • M. Embrey, E.E. Adams, B. Cunningham, W. Peters, V.L. Young, and G.L. Carlo A review of the literature on the etiology of capsular contracture and a pilot study to determine the outcome of capsular contracture interventions Aesthetic Plast. Surg. 23 1999 197 206
    • (1999) Aesthetic Plast. Surg. , vol.23 , pp. 197-206
    • Embrey, M.1    Adams, E.E.2    Cunningham, B.3    Peters, W.4    Young, V.L.5    Carlo, G.L.6
  • 5
    • 0029880545 scopus 로고    scopus 로고
    • Textured or smooth implants for submuscular breast augmentation: A controlled study
    • O. Asplund, L. Gylbert, G. Jurell, and C. Ward Textured or smooth implants for submuscular breast augmentation: a controlled study Plast. Reconstr. Surg. 97 1996 1200 1206
    • (1996) Plast. Reconstr. Surg. , vol.97 , pp. 1200-1206
    • Asplund, O.1    Gylbert, L.2    Jurell, G.3    Ward, C.4
  • 6
    • 0020595203 scopus 로고
    • Long-term comparison of patients with gel and saline mammary implants
    • P. McKinney, and G. Tresley Long-term comparison of patients with gel and saline mammary implants Plast. Reconstr. Surg. 72 1983 27 31
    • (1983) Plast. Reconstr. Surg. , vol.72 , pp. 27-31
    • McKinney, P.1    Tresley, G.2
  • 7
    • 0026594880 scopus 로고
    • A comparison of conventional and low-bleed implants in augmentation mammaplasty
    • L. Chang, E. Caldwell, G. Reading, and R.C. Wray A comparison of conventional and low-bleed implants in augmentation mammaplasty Plast. Reconstr. Surg. 89 1992 79 82
    • (1992) Plast. Reconstr. Surg. , vol.89 , pp. 79-82
    • Chang, L.1    Caldwell, E.2    Reading, G.3    Wray, R.C.4
  • 8
    • 0026795646 scopus 로고
    • Polyurethane-covered mammary implants: A 12-year experience
    • C. Gasperoni, M. Salgarello, and G. Gargani Polyurethane-covered mammary implants: a 12-year experience Ann. Plast. Surg. 29 1992 303 308
    • (1992) Ann. Plast. Surg. , vol.29 , pp. 303-308
    • Gasperoni, C.1    Salgarello, M.2    Gargani, G.3
  • 9
    • 0027940701 scopus 로고
    • Intracapsular injection of triamcinolone for intractable capsule contracture
    • H.H. Caffee Intracapsular injection of triamcinolone for intractable capsule contracture Plast. Reconstr. Surg. 94 1994 824 828
    • (1994) Plast. Reconstr. Surg. , vol.94 , pp. 824-828
    • Caffee, H.H.1
  • 10
    • 0035664636 scopus 로고    scopus 로고
    • Capsular contracture around saline-filled fine textured and smooth mammary implants: A prospective 7.5-year follow-up
    • D. Fagrell, A. Berggren, and E. Tarpila Capsular contracture around saline-filled fine textured and smooth mammary implants: a prospective 7.5-year follow-up Plast. Reconstr. Surg. 108 2001 2108 2112
    • (2001) Plast. Reconstr. Surg. , vol.108 , pp. 2108-2112
    • Fagrell, D.1    Berggren, A.2    Tarpila, E.3
  • 11
    • 0020063275 scopus 로고
    • Positive identification of silicone in human mammary capsular tissue
    • J.L. Baker Jr., R.R. LeVier, and D.E. Spielvogel Positive identification of silicone in human mammary capsular tissue Plast. Reconstr. Surg. 69 1982 56 60
    • (1982) Plast. Reconstr. Surg. , vol.69 , pp. 56-60
    • Baker Jr., J.L.1    Levier, R.R.2    Spielvogel, D.E.3
  • 12
    • 0028151201 scopus 로고
    • Histologic features of breast capsules reflect surface configuration and composition of silicone bag implants
    • C.S. Kasper Histologic features of breast capsules reflect surface configuration and composition of silicone bag implants Anat. Pathol. 102 1994 655 659
    • (1994) Anat. Pathol. , vol.102 , pp. 655-659
    • Kasper, C.S.1
  • 13
    • 0035134033 scopus 로고    scopus 로고
    • Étude au microscope ́lectronique ̀ balayage des surfaces des implants mammaires ̀ texturation poreuse et de leurs capsules. Description de l'effet « velcro » Des proth̀ses ̀ texturation poreuse
    • A. Danino, F. Rocher, C. Blanchet-Bardon, M. Revol, and J.M. Servant Étude au microscope ́lectronique ̀ balayage des surfaces des implants mammaires ̀ texturation poreuse et de leurs capsules. Description de l'effet « velcro » des proth̀ses ̀ texturation poreuse Ann. Chir. Plast. Esth́t. 46 2001 23 30
    • (2001) Ann. Chir. Plast. Esth́t. , vol.46 , pp. 23-30
    • Danino, A.1    Rocher, F.2    Blanchet-Bardon, C.3    Revol, M.4    Servant, J.M.5
  • 14
    • 0030940443 scopus 로고    scopus 로고
    • Textured surface silicone breast implants: Histology in the human
    • C.B. Lesesne Textured surface silicone breast implants: histology in the human Aesthetic Plast. Surg. 21 1997 93 96
    • (1997) Aesthetic Plast. Surg. , vol.21 , pp. 93-96
    • Lesesne, C.B.1
  • 15
    • 0031772760 scopus 로고    scopus 로고
    • The influence of time on human breast capsule histology: Smooth and textured silicone-surfaced implants
    • L.E. Wyatt, J.D. Sinow, J.S. Wollmann, D.A. Sami, and T.A. Miller The influence of time on human breast capsule histology: smooth and textured silicone-surfaced implants Plast. Reconstr. Surg. 102 1998 1922 1931
    • (1998) Plast. Reconstr. Surg. , vol.102 , pp. 1922-1931
    • Wyatt, L.E.1    Sinow, J.D.2    Wollmann, J.S.3    Sami, D.A.4    Miller, T.A.5
  • 16
    • 0023616779 scopus 로고
    • Breast augmentation: A review of subglandular and submuscular implantation
    • B. Vazquez, K.S. Given, and G.C. Houston Breast augmentation: a review of subglandular and submuscular implantation Aesthetic Plast. Surg. 11 1987 101 105
    • (1987) Aesthetic Plast. Surg. , vol.11 , pp. 101-105
    • Vazquez, B.1    Given, K.S.2    Houston, G.C.3
  • 17
    • 0028850615 scopus 로고
    • The effect of biocell texturing and povidone iodine irrigation on capsular contracture around saline-inflatable breast implants
    • B.R. Byrkhardt, and E. Eades The effect of biocell texturing and povidone iodine irrigation on capsular contracture around saline-inflatable breast implants Plast. Reconstr. Surg. 96 1995 1317 1325
    • (1995) Plast. Reconstr. Surg. , vol.96 , pp. 1317-1325
    • Byrkhardt, B.R.1    Eades, E.2
  • 18
    • 0026775256 scopus 로고
    • A clinical comparison of the tendency to capsular contracture between smooth and textured gel-filled silicone mammary implants
    • L. Hakelius, and L. Ohlsen A clinical comparison of the tendency to capsular contracture between smooth and textured gel-filled silicone mammary implants Plast. Reconstr. Surg. 90 1992 247 254
    • (1992) Plast. Reconstr. Surg. , vol.90 , pp. 247-254
    • Hakelius, L.1    Ohlsen, L.2
  • 19
    • 0000107418 scopus 로고
    • Relationships between spherical fibrous capsular contracture and mammary prosthesis type: A comparison of smooth and textured implants
    • J.A. McCurdy Relationships between spherical fibrous capsular contracture and mammary prosthesis type: a comparison of smooth and textured implants Am. J. Cosm. Surg. 7 1990 235 238
    • (1990) Am. J. Cosm. Surg. , vol.7 , pp. 235-238
    • McCurdy, J.A.1
  • 20
    • 0033865878 scopus 로고    scopus 로고
    • Ten-year review of a prospective randomized controlled trial of textured vs smooth subglandular silicone gel breast implants
    • N. Collis, D. Coleman, I.T.H. Foo, and D.T. Sharpe Ten-year review of a prospective randomized controlled trial of textured vs smooth subglandular silicone gel breast implants Plast. Recontr. Surg. 106 2000 786 791
    • (2000) Plast. Recontr. Surg. , vol.106 , pp. 786-791
    • Collis, N.1    Coleman, D.2    Foo, I.T.H.3    Sharpe, D.T.4
  • 21
    • 0030715320 scopus 로고    scopus 로고
    • Tendency to capsular contracture around smooth and textured gel-filled silicone mammary implants: A 5-year follow-up
    • L. Hakelius, and L. Ohlsen Tendency to capsular contracture around smooth and textured gel-filled silicone mammary implants: a 5-year follow-up Plast. Reconstr. Surg. 100 1997 1566 1569
    • (1997) Plast. Reconstr. Surg. , vol.100 , pp. 1566-1569
    • Hakelius, L.1    Ohlsen, L.2
  • 22
    • 0027257215 scopus 로고
    • "No-touch" submuscular saline breast augmentation technique
    • R.A. Mladick "No-touch" submuscular saline breast augmentation technique Aesthetic Plast. Surg. 17 1993 183 192
    • (1993) Aesthetic Plast. Surg. , vol.17 , pp. 183-192
    • Mladick, R.A.1
  • 23
    • 0027996768 scopus 로고
    • A rat model for capsular contracture: The effects of surface texturing
    • P.A. Clugston, L.C. Perry, D.C. Hammond, and G.P. Maxwell A rat model for capsular contracture: the effects of surface texturing Ann. Plast. Surg. 33 1994 595 599
    • (1994) Ann. Plast. Surg. , vol.33 , pp. 595-599
    • Clugston, P.A.1    Perry, L.C.2    Hammond, D.C.3    Maxwell, G.P.4
  • 24
    • 0026658882 scopus 로고
    • Eighty-four consecutive breast reconstructions using a textured silicone tissue expander
    • G.P. Maxwell, and P.A. Falcone Eighty-four consecutive breast reconstructions using a textured silicone tissue expander Plast. Reconstr. Surg. 89 1992 1022 1034
    • (1992) Plast. Reconstr. Surg. , vol.89 , pp. 1022-1034
    • Maxwell, G.P.1    Falcone, P.A.2
  • 25
    • 0034068016 scopus 로고    scopus 로고
    • Textured-surface saline-filled silicone breast implants for augmentation mammaplasty
    • S.L. Spear, M. Elmaraghy, and C. Hess Textured-surface saline-filled silicone breast implants for augmentation mammaplasty Plast. Reconstr. Surg. 105 2000 1542 1552
    • (2000) Plast. Reconstr. Surg. , vol.105 , pp. 1542-1552
    • Spear, S.L.1    Elmaraghy, M.2    Hess, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.