-
2
-
-
0028904705
-
A velocity k-space analysis of flow effects in echo-planar and spiral imaging
-
Nishimura DG, Irarrazabal P, Meyer CH. A velocity k-space analysis of flow effects in echo-planar and spiral imaging. Magn Reson Med 1995; 33:549-556.
-
(1995)
Magn Reson Med
, vol.33
, pp. 549-556
-
-
Nishimura, D.G.1
Irarrazabal, P.2
Meyer, C.H.3
-
4
-
-
0023669873
-
Spiral sampling in magnetic resonance imaging - The effect of inhomogeneties
-
Yudilevich E, Stark H. Spiral sampling in magnetic resonance imaging-the effect of inhomogeneties. IEEE Trans Med Imaging 1987;6:337-345.
-
(1987)
IEEE Trans Med Imaging
, vol.6
, pp. 337-345
-
-
Yudilevich, E.1
Stark, H.2
-
5
-
-
0035180446
-
Design of a logarithmic k-space spiral trajectory
-
Cline HE, Zong X, Gai N. Design of a logarithmic k-space spiral trajectory. Magn Reson Med 2001;46:1130-1135.
-
(2001)
Magn Reson Med
, vol.46
, pp. 1130-1135
-
-
Cline, H.E.1
Zong, X.2
Gai, N.3
-
6
-
-
0032818760
-
Simple analytic spiral k-space algorithm
-
Glover GH. Simple analytic spiral k-space algorithm. Magn Reson Med 1999;42:412-415.
-
(1999)
Magn Reson Med
, vol.42
, pp. 412-415
-
-
Glover, G.H.1
-
7
-
-
0028957906
-
Fast three dimensional magnetic resonance imaging
-
Irarrazaval P, Nishimura DG. Fast three dimensional magnetic resonance imaging. Magn Reson Med 1995;33:656-662.
-
(1995)
Magn Reson Med
, vol.33
, pp. 656-662
-
-
Irarrazaval, P.1
Nishimura, D.G.2
-
8
-
-
0027093023
-
Projection reconstruction techniques for reduction of flow motion effects in MRI
-
Glover GH, Pauly J. Projection reconstruction techniques for reduction of flow motion effects in MRI. Magn Reson Med 1992;28:275-289.
-
(1992)
Magn Reson Med
, vol.28
, pp. 275-289
-
-
Glover, G.H.1
Pauly, J.2
-
9
-
-
0032980635
-
Fast magnetic resonance imaging of the heart
-
Sakuma H, Takedaa K, Higgins CB. Fast magnetic resonance imaging of the heart. Eur J Radiol 1999;29:101-113.
-
(1999)
Eur J Radiol
, vol.29
, pp. 101-113
-
-
Sakuma, H.1
Takedaa, K.2
Higgins, C.B.3
-
10
-
-
0034120692
-
Reconstructing MR images from undersampled data: Data-weighting considerations
-
Pipe JG. Reconstructing MR images from undersampled data: data-weighting considerations. Magn Reson Med 2000;43:867-875.
-
(2000)
Magn Reson Med
, vol.43
, pp. 867-875
-
-
Pipe, J.G.1
-
11
-
-
0027216220
-
k-Space substitution: A novel dynamic imaging technique
-
Jones RA, Haraldseth O, Muler TB, Rinck PA, Oksendal AN. k-Space substitution: a novel dynamic imaging technique. Magn Reson Med 1993;29:830-834.
-
(1993)
Magn Reson Med
, vol.29
, pp. 830-834
-
-
Jones, R.A.1
Haraldseth, O.2
Muler, T.B.3
Rinck, P.A.4
Oksendal, A.N.5
-
12
-
-
0034007629
-
Reduced aliasing artifacts using variable-density k-space sampling trajectories
-
Tsai CM, Nishimura DG. Reduced aliasing artifacts using variable-density k-space sampling trajectories. Magn Reson Med 2000;43:452-458.
-
(2000)
Magn Reson Med
, vol.43
, pp. 452-458
-
-
Tsai, C.M.1
Nishimura, D.G.2
-
13
-
-
3543076495
-
Fast three dimensional k-space trajectory design using missile guidance ideas
-
Mir R, Guesalaga A, Spiniak J, Guarini M, Irarrazaval P. Fast three dimensional k-space trajectory design using missile guidance ideas. Magn Reson Med 2004;52:329-336.
-
(2004)
Magn Reson Med
, vol.52
, pp. 329-336
-
-
Mir, R.1
Guesalaga, A.2
Spiniak, J.3
Guarini, M.4
Irarrazaval, P.5
-
15
-
-
0030951601
-
Fast three dimensional sodium imaging
-
Boada F, Gillen J, Shen G, Chang S, Thulborn K. Fast three dimensional sodium imaging. Magn Reson Med 1997;37:706-715.
-
(1997)
Magn Reson Med
, vol.37
, pp. 706-715
-
-
Boada, F.1
Gillen, J.2
Shen, G.3
Chang, S.4
Thulborn, K.5
-
18
-
-
0032957342
-
Sampling density compensation in MRI: Rationale and an iterative numerical solution
-
Pipe JG, Menon P. Sampling density compensation in MRI: rationale and an iterative numerical solution. Magn Reson Med 1999;41:179-186.
-
(1999)
Magn Reson Med
, vol.41
, pp. 179-186
-
-
Pipe, J.G.1
Menon, P.2
-
19
-
-
0032588591
-
Resampling of data between arbitrary grids using convolution interpolation
-
Rasche V, Proska R, Sinkus R, Bornert P, Eggers H. Resampling of data between arbitrary grids using convolution interpolation. IEEE Trans Med Imaging 1999;18:385-392.
-
(1999)
IEEE Trans Med Imaging
, vol.18
, pp. 385-392
-
-
Rasche, V.1
Proska, R.2
Sinkus, R.3
Bornert, P.4
Eggers, H.5
-
20
-
-
0034351120
-
Reconstruction of MR images from data acquired on a general nonregular grid by pseudoinverse calculation
-
Walle RV, Barret HH, Myers KJ, Altbach MI, Desplanques B, Gmitro AF, Cornelis J, Lemahieu I. Reconstruction of MR images from data acquired on a general nonregular grid by pseudoinverse calculation. IEEE Trans Med Imaging 2000;19:1160-1167.
-
(2000)
IEEE Trans Med Imaging
, vol.19
, pp. 1160-1167
-
-
Walle, R.V.1
Barret, H.H.2
Myers, K.J.3
Altbach, M.I.4
Desplanques, B.5
Gmitro, A.F.6
Cornelis, J.7
Lemahieu, I.8
-
21
-
-
0030705199
-
Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging
-
Wilman AH, Riederer SJ. Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging. Magn Reson Med 1997;38:793-802.
-
(1997)
Magn Reson Med
, vol.38
, pp. 793-802
-
-
Wilman, A.H.1
Riederer, S.J.2
|