메뉴 건너뛰기




Volumn 23, Issue 6, 2005, Pages 414-417

Two-phase CT pulmonary angiography for detection of hilar pulmonary thromboembolism

Author keywords

CT pulmonary angiography; Pulmonary thromboembolism; Saline solution flush

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; ASCENDING AORTA; ATTENUATION; CLINICAL ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; FEMALE; HUMAN; LUNG ANGIOGRAPHY; LUNG EMBOLISM; LUNG HILUS; MALE; PULMONARY ARTERY;

EID: 26644468603     PISSN: 02882043     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (15)
  • 1
    • 0029026454 scopus 로고
    • Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: Helical CT versus angiography
    • Goodman LR, Curtin JJ, Mewissen MW, et al. Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: helical CT versus angiography. AJR Am J Roentgenol, 164: 1369-1374, 1995.
    • (1995) AJR Am J Roentgenol , vol.164 , pp. 1369-1374
    • Goodman, L.R.1    Curtin, J.J.2    Mewissen, M.W.3
  • 2
    • 0032874595 scopus 로고    scopus 로고
    • Spiral CT angiography of the pulmonary circulation
    • Remy-Jardin M, Remy J. Spiral CT angiography of the pulmonary circulation. Radiology, 212: 615-636, 1999.
    • (1999) Radiology , vol.212 , pp. 615-636
    • Remy-Jardin, M.1    Remy, J.2
  • 3
    • 0036153994 scopus 로고    scopus 로고
    • Subsegmental pulmonary emboli: Improved detection with thin-collimation multi-detector row spiral CT
    • Schoepf UJ, Holzknecht N, Helmberger TK, et al. Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology, 222: 483-490, 2002.
    • (2002) Radiology , vol.222 , pp. 483-490
    • Schoepf, U.J.1    Holzknecht, N.2    Helmberger, T.K.3
  • 4
    • 0037406918 scopus 로고    scopus 로고
    • Pulmonary embolism: Optimization of small pulmonary artery visualization at multi-detector row CT
    • Patel S, Kazerooni EA, Cascade PN. Pulmonary embolism: optimization of small pulmonary artery visualization at multi-detector row CT. Radiology, 227: 455-460, 2003.
    • (2003) Radiology , vol.227 , pp. 455-460
    • Patel, S.1    Kazerooni, E.A.2    Cascade, P.N.3
  • 5
    • 0025354523 scopus 로고
    • Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED)
    • The PIOPED Investigators
    • Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED). The PIOPED Investigators. JAMA, 263: 2753-2759, 1990.
    • (1990) JAMA , vol.263 , pp. 2753-2759
  • 6
    • 0029915329 scopus 로고    scopus 로고
    • Anatomic distribution of pulmonary emboli at pulmonary angiography: Implications for cross-sectional imaging
    • Oser RF, Zuckerman DA, Gutierrez FR, Brink JA. Anatomic distribution of pulmonary emboli at pulmonary angiography: implications for cross-sectional imaging. Radiology, 199: 31-35, 1996.
    • (1996) Radiology , vol.199 , pp. 31-35
    • Oser, R.F.1    Zuckerman, D.A.2    Gutierrez, F.R.3    Brink, J.A.4
  • 7
    • 0031871711 scopus 로고    scopus 로고
    • Correlation of diagnostic imaging and subsequent autopsy findings in patients with pulmonary embolism
    • Patriquin L, Khorasani R, Polak JF. Correlation of diagnostic imaging and subsequent autopsy findings in patients with pulmonary embolism. AJR Am J Roentgenol, 171: 347-349, 1998.
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 347-349
    • Patriquin, L.1    Khorasani, R.2    Polak, J.F.3
  • 8
    • 0028107564 scopus 로고
    • A noninvasive strategy for the treatment of patients with suspected pulmonary embolism
    • Hull RD, Raskob GE, Ginsberg JS, et al. A noninvasive strategy for the treatment of patients with suspected pulmonary embolism. Arch Intern Med, 154: 289-297, 1994.
    • (1994) Arch Intern Med , vol.154 , pp. 289-297
    • Hull, R.D.1    Raskob, G.E.2    Ginsberg, J.S.3
  • 9
    • 0029890837 scopus 로고    scopus 로고
    • Deep venous thrombosis of the lower extremity: Efficacy of spiral CT venography compared with conventional venography in diagnosis
    • Baldt MM, Zontsich T, Stumpflen A, et al. Deep venous thrombosis of the lower extremity: efficacy of spiral CT venography compared with conventional venography in diagnosis. Radiology, 200: 423-428, 1996.
    • (1996) Radiology , vol.200 , pp. 423-428
    • Baldt, M.M.1    Zontsich, T.2    Stumpflen, A.3
  • 10
    • 0002412354 scopus 로고
    • Fatal pulmonary emboli; a study of 130 autopsy proven fatal emboli
    • Byrne JJ, O'Neil EE. Fatal pulmonary emboli; a study of 130 autopsy proven fatal emboli. Am J Surg, 83: 47-49, 1952.
    • (1952) Am J Surg , vol.83 , pp. 47-49
    • Byrne, J.J.1    O'Neil, E.E.2
  • 11
    • 0036777379 scopus 로고    scopus 로고
    • Combined CT venography and pulmonary angiography: A comprehensive review
    • Katz DS, Loud PA, Bruce D, et al. Combined CT venography and pulmonary angiography: a comprehensive review. Radiographics, 22: S3-24, 2002.
    • (2002) Radiographics , vol.22
    • Katz, D.S.1    Loud, P.A.2    Bruce, D.3
  • 12
    • 0033989257 scopus 로고    scopus 로고
    • Combined CT venography and pulmonary angiography in suspected thromboembolic disease: Diagnostic accuracy for deep venous evaluation
    • Loud PA, Katz DS, Klippenstein DL, Shah RD, Grossman ZD. Combined CT venography and pulmonary angiography in suspected thromboembolic disease: diagnostic accuracy for deep venous evaluation. AJR Am J Roentgenol, 174: 61-65, 2000.
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 61-65
    • Loud, P.A.1    Katz, D.S.2    Klippenstein, D.L.3    Shah, R.D.4    Grossman, Z.D.5
  • 13
    • 0033797103 scopus 로고    scopus 로고
    • Thromboembolic disease: Comparison of combined CT pulmonary angiography and venography with bilateral leg sonography in 70 patients
    • Garg K, Kemp JL, Wojcik D, et al. Thromboembolic disease: comparison of combined CT pulmonary angiography and venography with bilateral leg sonography in 70 patients. AJR Am J Roentgenol, 175: 997-1001, 2000.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 997-1001
    • Garg, K.1    Kemp, J.L.2    Wojcik, D.3
  • 14
    • 0034112337 scopus 로고    scopus 로고
    • Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax
    • Haage P, Schmitz-Rode T, Hubner D, Piroth W, Gunther RW. Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. AJR Am J Roentgenol, 174: 1049-1053, 2000.
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 1049-1053
    • Haage, P.1    Schmitz-Rode, T.2    Hubner, D.3    Piroth, W.4    Gunther, R.W.5
  • 15
    • 0030825080 scopus 로고    scopus 로고
    • Thoracic spiral CT: Delivery of contrast material pushed with injectable saline solution in a power injector
    • Hopper KD, Mosher TJ, Kasales CJ, TenHave TR, Tully DA, Weaver JS. Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector. Radiology, 205: 269-271, 1997.
    • (1997) Radiology , vol.205 , pp. 269-271
    • Hopper, K.D.1    Mosher, T.J.2    Kasales, C.J.3    TenHave, T.R.4    Tully, D.A.5    Weaver, J.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.