Volumn 66, Issue 2, 2005, Pages 273-276

Late coil displacement after interventional closure of a perimembranous ventricular septal defect: A case report

Author keywords

Coil displacement; Interventional closure; Ventricular septal defect

Indexed keywords

NITINOL;

EID: 26644460880     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/ccd.20452     Document Type: Article
Times cited : (4)

References (8)
  • 1
    • 0037303172 scopus 로고    scopus 로고
    • Experience with transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: A single centre study in 236 consecutive patients
    • Fischer G, Stieh J, Uebing A, Hoffmann U, Morf G, Kramer HH. Experience with transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: a single centre study in 236 consecutive patients. Heart 2003;89:199-204.
    • (2003) Heart , vol.89 , pp. 199-204
    • Fischer, G.1    Stieh, J.2    Uebing, A.3    Hoffmann, U.4    Morf, G.5    Kramer, H.H.6
  • 3
    • 1842531950 scopus 로고    scopus 로고
    • Transcetheter closure of the patent ductus arteriosus
    • Grifka RG. Transcetheter closure of the patent ductus arteriosus. Catheter Cardiovasc Interv 2004;61:554-570.
    • (2004) Catheter Cardiovasc Interv , vol.61 , pp. 554-570
    • Grifka, R.G.1
  • 4
    • 1842478193 scopus 로고    scopus 로고
    • Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal occluder: Immediate and mid-term results of a US registry
    • Holzer R, Balzer D, Cao QL, Lock K, Hijazi ZM. Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal occluder: immediate and mid-term results of a US registry. J Am Coll Cardiol 2004;43:1257-1263.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1257-1263
    • Holzer, R.1    Balzer, D.2    Cao, Q.L.3    Lock, K.4    Hijazi, Z.M.5
  • 5
    • 0034765395 scopus 로고    scopus 로고
    • Transcatheter occlusion of subaortic ventricular septal defects (VSD) using a nickel-titanium spiral coil (NitOcclud): Animal study and initial clinical results
    • Lê TP, Vaessen P, Freudenthal F, Grabitz RG, Sievert H. Transcatheter occlusion of subaortic ventricular septal defects (VSD) using a nickel-titanium spiral coil (NitOcclud): animal study and initial clinical results. Prog Pediatr Cardiol 2001;14:83-88.
    • (2001) Prog Pediatr Cardiol , vol.14 , pp. 83-88
    • Lê, T.P.1    Vaessen, P.2    Freudenthal, F.3    Grabitz, R.G.4    Sievert, H.5
  • 8
    • 26644441359 scopus 로고    scopus 로고
    • Transcatheter occlusion of subaortic ventricular septal defect using a nitinol coil (NitOcclud): Initial clinical results
    • Lê TP, Freudenthal F, Sievert H, Vaessen P, Grabitz R. Transcatheter occlusion of subaortic ventricular septal defect using a nitinol coil (NitOcclud): initial clinical results. Circulation 2001;104(Suppl 2):593.
    • (2001) Circulation , vol.104 , Issue.SUPPL. 2 , pp. 593
    • Lê, T.P.1    Freudenthal, F.2    Sievert, H.3    Vaessen, P.4    Grabitz, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.