메뉴 건너뛰기




Volumn 36, Issue 11, 2005, Pages 1343-1349

Percutaneous compression plating versus compression hip screw fixation for the treatment of intertrochanteric hip fractures

Author keywords

Compression hip screw; Hip fracture; Minimally invasive surgery; Percutaneous compression plate

Indexed keywords

AGED; ARTICLE; BLOOD TRANSFUSION; BONE PLATE; BONE SCREW; CARDIOVASCULAR DISEASE; CONTROLLED STUDY; DEVICE; FEMALE; FEMUR INTERTROCHANTERIC FRACTURE; FRACTURE FIXATION; HIP FRACTURE; HOSPITALIZATION; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MORBIDITY; MORTALITY; MULTIVARIATE ANALYSIS; OPERATION DURATION; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SCORING SYSTEM; SURGICAL TECHNIQUE; TREATMENT FAILURE; TREATMENT OUTCOME;

EID: 26444520773     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2004.09.014     Document Type: Article
Times cited : (33)

References (25)
  • 1
    • 0035203607 scopus 로고    scopus 로고
    • Prospective randomised controlled trial of an intramedullary nail versus dynamic screw and plate for intetrochanteric fractures of the femur
    • C.I. Adams, C.M. Robinson, C.M. Court-Brown, and M.M. McQueen Prospective randomised controlled trial of an intramedullary nail versus dynamic screw and plate for intetrochanteric fractures of the femur J Orthop Trauma 15 2001 394 400
    • (2001) J Orthop Trauma , vol.15 , pp. 394-400
    • Adams, C.I.1    Robinson, C.M.2    Court-Brown, C.M.3    McQueen, M.M.4
  • 2
    • 0031924186 scopus 로고    scopus 로고
    • Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures
    • M.R. Baumgaertner, S.L. Curtin, and D.M. Lindskog Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures Clin Orthop 348 1998 87 94
    • (1998) Clin Orthop , vol.348 , pp. 87-94
    • Baumgaertner, M.R.1    Curtin, S.L.2    Lindskog, D.M.3
  • 3
    • 0028169749 scopus 로고
    • Collapse of intertrochanteric hip fractures fixed with sliding screws
    • Bendo JA, Weiner LS, Strauss E, Yang E. Collapse of intertrochanteric hip fractures fixed with sliding screws. Orthop Rev 1994;August Suppl:30-7.
    • (1994) Orthop Rev , Issue.AUGUST SUPPL. , pp. 30-37
    • Bendo, J.A.1    Weiner, L.S.2    Strauss, E.3    Yang, E.4
  • 4
    • 0036298615 scopus 로고    scopus 로고
    • Percutaneous compression plating (PCCP) versus the dynamic hip screw for pertrochanteric hip fractures: Preliminary results
    • S.E. Brandt, S. Lefever, and H.M.J. Janzing Percutaneous compression plating (PCCP) versus the dynamic hip screw for pertrochanteric hip fractures: preliminary results Injury 33 2002 413 418
    • (2002) Injury , vol.33 , pp. 413-418
    • Brandt, S.E.1    Lefever, S.2    Janzing, H.M.J.3
  • 6
    • 0035079485 scopus 로고    scopus 로고
    • RAB-plate versus sliding hip screw for unstable trochanteric hip fractures: Stability of the fixation and modes of failure - Radiographic analysis of 218 fractures
    • R. Buciuto, and R. Hammer RAB-plate versus sliding hip screw for unstable trochanteric hip fractures: stability of the fixation and modes of failure - radiographic analysis of 218 fractures J Trauma 50 2001 545 550
    • (2001) J Trauma , vol.50 , pp. 545-550
    • Buciuto, R.1    Hammer, R.2
  • 8
    • 0025034792 scopus 로고
    • Intertrochanteric femoral fractures: Mechanical failure after internal fixation
    • T.R.C. Davis, J.L. Sher, and A. Horsman Intertrochanteric femoral fractures: mechanical failure after internal fixation J Bone Joint Surg 72 B 1990 26 31
    • (1990) J Bone Joint Surg , vol.72 , pp. 26-31
    • Davis, T.R.C.1    Sher, J.L.2    Horsman, A.3
  • 9
    • 0019305579 scopus 로고
    • The sliding compression screw - Today's best answer for stabilization of intertrochanteric hip fractures
    • S.H. Doppelt The sliding compression screw - today's best answer for stabilization of intertrochanteric hip fractures Orthop Clin North Am 11 1980 507 523
    • (1980) Orthop Clin North Am , vol.11 , pp. 507-523
    • Doppelt, S.H.1
  • 10
    • 0035203345 scopus 로고    scopus 로고
    • Prospective randomized comparison between a dynamic hip screw and a mini-invasive static nail in fractures of the trochanteric area: Preliminary results
    • F.H. Dujardin, C. Benez, and G. Polle Prospective randomized comparison between a dynamic hip screw and a mini-invasive static nail in fractures of the trochanteric area: preliminary results J Orthop Trauma 15 2001 401 406
    • (2001) J Orthop Trauma , vol.15 , pp. 401-406
    • Dujardin, F.H.1    Benez, C.2    Polle, G.3
  • 12
    • 0025069811 scopus 로고
    • The stability of intertrochanteric fractures treated with a sliding screw-plate
    • L.A. Flores, I.J. Harrington, and M. Heller The stability of intertrochanteric fractures treated with a sliding screw-plate J Bone Joint Surg 72 B 1990 37 40
    • (1990) J Bone Joint Surg , vol.72 , pp. 37-40
    • Flores, L.A.1    Harrington, I.J.2    Heller, M.3
  • 13
    • 0034279730 scopus 로고    scopus 로고
    • Percutaneous compression plating of intertrochanteric hip fractures
    • Y. Gotfried Percutaneous compression plating of intertrochanteric hip fractures J Orthop Trauma 14 2000 490 495
    • (2000) J Orthop Trauma , vol.14 , pp. 490-495
    • Gotfried, Y.1
  • 14
    • 0036142619 scopus 로고    scopus 로고
    • The relationship between admission hemoglobin level and outcome after hip fracture
    • K.I. Gruson, G.B. Aharonoff, and K.A. Egol The relationship between admission hemoglobin level and outcome after hip fracture J Orthop Trauma 16 2002 39 44
    • (2002) J Orthop Trauma , vol.16 , pp. 39-44
    • Gruson, K.I.1    Aharonoff, G.B.2    Egol, K.A.3
  • 15
    • 0031808886 scopus 로고    scopus 로고
    • Use of an intramedullay hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures
    • D.C.R. Hardy, P.Y. Descamps, and P. Krallis Use of an intramedullay hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures J Bone Joint Surg 80 A 1998 618 630
    • (1998) J Bone Joint Surg , vol.80 , pp. 618-630
    • Hardy, D.C.R.1    Descamps, P.Y.2    Krallis, P.3
  • 16
    • 0036189124 scopus 로고    scopus 로고
    • The Gottfried percutaneous compression plate versus the dynamic hip screw in the treatment of pertrochanteric hip fractures: Minimal invasive treatment reduces operative time and postoperative pain
    • H.M.J. Janzing, B.J.J. Houben, and S.E. Brandt The Gottfried percutaneous compression plate versus the dynamic hip screw in the treatment of pertrochanteric hip fractures: minimal invasive treatment reduces operative time and postoperative pain J Trauma 52 2 2002 293 298
    • (2002) J Trauma , vol.52 , Issue.2 , pp. 293-298
    • Janzing, H.M.J.1    Houben, B.J.J.2    Brandt, S.E.3
  • 17
    • 0018931431 scopus 로고
    • Classification of trochanteric fractures
    • J.S. Jensen Classification of trochanteric fractures Acta Orthop Scand 51 1980 803 810
    • (1980) Acta Orthop Scand , vol.51 , pp. 803-810
    • Jensen, J.S.1
  • 18
    • 0021187653 scopus 로고
    • Hip fracture mortality: Relation to age, treatment, preoperative illness, time of surgery, and complications
    • J.E. Kenzora, R.E. McCarthy, J.D. Lowell, and C.B. Sledge Hip fracture mortality: relation to age, treatment, preoperative illness, time of surgery, and complications Clin Orthop 186 1984 45 56
    • (1984) Clin Orthop , vol.186 , pp. 45-56
    • Kenzora, J.E.1    McCarthy, R.E.2    Lowell, J.D.3    Sledge, C.B.4
  • 19
    • 0036151151 scopus 로고    scopus 로고
    • The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip
    • K.P. Kosygan, R. Mohan, and R.J. Newman The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip J Bone Joint Surg 84 B 2002 19 22
    • (2002) J Bone Joint Surg , vol.84 , pp. 19-22
    • Kosygan, K.P.1    Mohan, R.2    Newman, R.J.3
  • 20
    • 0037078297 scopus 로고    scopus 로고
    • Medical complications and outcomes after hip fracture repair
    • V.A. Lawrence, S.G. Hilsenbeck, and H. Noveck Medical complications and outcomes after hip fracture repair Arch Intern Med 162 2002 2053 2057
    • (2002) Arch Intern Med , vol.162 , pp. 2053-2057
    • Lawrence, V.A.1    Hilsenbeck, S.G.2    Noveck, H.3
  • 21
    • 0037222379 scopus 로고    scopus 로고
    • Preoperative cardiac events in elderly patients with hip fracture randomized to epidural or conventional analgesia
    • I. Matot, A. Oppenheim-Eden, and R. Ratrot Preoperative cardiac events in elderly patients with hip fracture randomized to epidural or conventional analgesia Anesthesiology 98 2003 156 163
    • (2003) Anesthesiology , vol.98 , pp. 156-163
    • Matot, I.1    Oppenheim-Eden, A.2    Ratrot, R.3
  • 22
    • 0036528711 scopus 로고    scopus 로고
    • National consensus conference on improving the continuum of care for patients with hip fracture
    • A.H. Morris, and J.D. Zuckerman National consensus conference on improving the continuum of care for patients with hip fracture J Bone Joint Surg 84 A 2002 670 674
    • (2002) J Bone Joint Surg , vol.84 , pp. 670-674
    • Morris, A.H.1    Zuckerman, J.D.2
  • 23
    • 0003179093 scopus 로고    scopus 로고
    • OTA fracture and dislocation compendium
    • OTA fracture and dislocation compendium. J Orthop Trauma 1996;10 (Suppl. 1):32-5.
    • (1996) J Orthop Trauma , vol.10 , Issue.1 SUPPL. , pp. 32-35
  • 25
    • 0024328634 scopus 로고
    • Sliding hip screws: Modes of failure
    • A.H.R.W. Simpson, K. Varty, and C.A.F. Dodd Sliding hip screws: modes of failure Injury 20 1989 227 231
    • (1989) Injury , vol.20 , pp. 227-231
    • Simpson, A.H.R.W.1    Varty, K.2    Dodd, C.A.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.