메뉴 건너뛰기




Volumn 133, Issue 4, 2005, Pages 531-533

Radiation dose to the eyes and parotids during CT of the sinuses

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CADAVER; CATARACT; COMPUTER PROGRAM; EYE; HIGH RESOLUTION COMPUTER TOMOGRAPHY; HUMAN; IMAGING SYSTEM; LENS; PAROTID GLAND; PAROTID GLAND DISEASE; RADIATION ABSORPTION; RADIATION DOSE; RADIATION HAZARD; THERMOLUMINESCENCE DOSIMETER;

EID: 26444483231     PISSN: 01945998     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.otohns.2005.06.018     Document Type: Article
Times cited : (26)

References (17)
  • 1
    • 0034889239 scopus 로고    scopus 로고
    • Radiation dose to the lens in sequential and spiral CT of the facial bones and sinuses
    • J. Czechowski, J. Janeczek, G. Kelly Radiation dose to the lens in sequential and spiral CT of the facial bones and sinuses Eur Radiol 11 2001 711 713
    • (2001) Eur Radiol , vol.11 , pp. 711-713
    • Czechowski, J.1    Janeczek, J.2    Kelly, G.3
  • 2
    • 0031612365 scopus 로고    scopus 로고
    • Possibilities for dose reduction in coronal spiral CT of the mid-face area
    • M. Cohnen, B. Cohnen, J.A. Koch Possibilities for dose reduction in coronal spiral CT of the mid-face area Aktuelle Radiol 8 1998 34 39
    • (1998) Aktuelle Radiol , vol.8 , pp. 34-39
    • Cohnen, M.1    Cohnen, B.2    Koch, J.A.3
  • 6
    • 0031819388 scopus 로고    scopus 로고
    • CT scanning of the paranasal sinuses: Axial helical CT with reconstruction in the coronal direction versus coronal helical CT
    • T.M. Bernhardt, U. Rapp-Bernhardt, A. Fessel CT scanning of the paranasal sinuses axial helical CT with reconstruction in the coronal direction versus coronal helical CT Br J Radiol 71 1998 846 851
    • (1998) Br J Radiol , vol.71 , pp. 846-851
    • Bernhardt, T.M.1    Rapp-Bernhardt, U.2    Fessel, A.3
  • 7
    • 0038481248 scopus 로고    scopus 로고
    • Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CT
    • I. Zammit-Maempel, C.L. Chadwick, S.P. Willis Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CT Br J Radiol 76 2003 418 420
    • (2003) Br J Radiol , vol.76 , pp. 418-420
    • Zammit-Maempel, I.1    Chadwick, C.L.2    Willis, S.P.3
  • 8
    • 0030666397 scopus 로고    scopus 로고
    • CT scanning of the paranasal sinuses - The effect of reducing mAs
    • S.E. Kearney, P. Jones, K. Meakin CT scanning of the paranasal sinuses - the effect of reducing mAs Br J Radiol 70 1997 1071 1074
    • (1997) Br J Radiol , vol.70 , pp. 1071-1074
    • Kearney, S.E.1    Jones, P.2    Meakin, K.3
  • 9
    • 0035085941 scopus 로고    scopus 로고
    • The effect of decreasing mAs on image quality and patient dose in sinus CT
    • S.A. Sohaib, P.D. Peppercorn, J.A. Horrocks The effect of decreasing mAs on image quality and patient dose in sinus CT Br J Radiol 74 2001 157 161
    • (2001) Br J Radiol , vol.74 , pp. 157-161
    • Sohaib, S.A.1    Peppercorn, P.D.2    Horrocks, J.A.3
  • 10
    • 0028414512 scopus 로고
    • Radiation doses delivered to the critical organs during radiological studies of chronic sinusitis: Comparison between TDM and standard radiographies]
    • S. Nadas, B. Duvoisin, S. Raimondi Radiation doses delivered to the critical organs during radiological studies of chronic sinusitis comparison between TDM and standard radiographies] J Radiol 75 1994 217 219
    • (1994) J Radiol , vol.75 , pp. 217-219
    • Nadas, S.1    Duvoisin, B.2    Raimondi, S.3
  • 12
    • 0029973522 scopus 로고    scopus 로고
    • Radiation dose to the lenses in CT of the paranasal sinuses
    • G. Moulin, C. Chagnaud, S. Waultier Radiation dose to the lenses in CT of the paranasal sinuses Neuroradiology 38 suppl 1 1996 S127 S129
    • (1996) Neuroradiology , vol.38 , Issue.SUPPL. 1
    • Moulin, G.1    Chagnaud, C.2    Waultier, S.3
  • 14
    • 0028827496 scopus 로고
    • Charing Cross CT protocol for endoscopic sinus surgery
    • J. Rowe-Jones, I. Mackay, I. Colquhoun Charing Cross CT protocol for endoscopic sinus surgery J Laryngol Otol 109 1995 1057 1060
    • (1995) J Laryngol Otol , vol.109 , pp. 1057-1060
    • Rowe-Jones, J.1    MacKay, I.2    Colquhoun, I.3
  • 15
    • 0028958550 scopus 로고
    • Radiation dose to the lens from coronal CT scanning of the sinuses
    • A.C. MacLennan Radiation dose to the lens from coronal CT scanning of the sinuses Clin Radiol 50 1995 265 267
    • (1995) Clin Radiol , vol.50 , pp. 265-267
    • MacLennan, A.C.1
  • 16
    • 0022457404 scopus 로고
    • Acute and late radiation injury in rhesus monkey parotid glands: Evidence of interphase cell death
    • L.C. Stephens, G.K. King, L.J. Peters Acute and late radiation injury in rhesus monkey parotid glands evidence of interphase cell death Am J Pathol 124 1986 469 478
    • (1986) Am J Pathol , vol.124 , pp. 469-478
    • Stephens, L.C.1    King, G.K.2    Peters, L.J.3
  • 17
    • 0025819169 scopus 로고
    • Radiation apoptosis of serous acinar cells of salivary and lacrimal glands
    • L.C. Stephens, T.E. Schultheiss, R.E. Price Radiation apoptosis of serous acinar cells of salivary and lacrimal glands Cancer 67 1991 1539 1543
    • (1991) Cancer , vol.67 , pp. 1539-1543
    • Stephens, L.C.1    Schultheiss, T.E.2    Price, R.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.