Volumn 39, Issue 3, 1998, Pages 411-416

Effects of misalignment between transmission and emission scans on attenuation-corrected cardiac SPECT

Author keywords

Attenuation correction; Emission scans; Misalignment; SPECT; Transmission

Indexed keywords

METHOXY ISOBUTYL ISONITRILE TECHNETIUM TC 99M;

EID: 2642676018     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (46)

References (16)
  • 1
    • 0029077501 scopus 로고
    • Attenuation correction in cardiac positron emission tomography and single-photon emission computed tomography
    • Bacharach S, Buvat I. Attenuation correction in cardiac positron emission tomography and single-photon emission computed tomography. J Nucl Cardiol 1995;2:246-255.
    • (1995) J Nucl Cardiol , vol.2 , pp. 246-255
    • Bacharach, S.1    Buvat, I.2
  • 2
    • 0029564459 scopus 로고
    • Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps
    • King M, Tsui B, Pan T. Attenuation compensation for cardiac single-photon emission computed tomographic imaging: part 1. Impact of attenuation and methods of estimating attenuation maps. J Nucl Cardial 1995;2:513-524.
    • (1995) J Nucl Cardial , vol.2 , pp. 513-524
    • King, M.1    Tsui, B.2    Pan, T.3
  • 3
    • 0030070816 scopus 로고    scopus 로고
    • Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms
    • King M, Tsui B, Pan T, Gtick S, Soares E. Attenuation compensation for cardiac single-photon emission computed tomographic imaging: part 2. Attenuation compensation algorithms. J Nucl Cardiol 1996;3:55-63.
    • (1996) J Nucl Cardiol , vol.3 , pp. 55-63
    • King, M.1    Tsui, B.2    Pan, T.3    Gtick, S.4    Soares, E.5
  • 4
    • 0030022458 scopus 로고    scopus 로고
    • Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography
    • Ficaro EP, Fessier JA, Shreve PD, Kritzman JN, Rose PA, Corbett JR. Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography. Circulation 1996;93:463-473.
    • (1996) Circulation , vol.93 , pp. 463-473
    • Ficaro, E.P.1    Fessier, J.A.2    Shreve, P.D.3    Kritzman, J.N.4    Rose, P.A.5    Corbett, J.R.6
  • 5
    • 25544455300 scopus 로고    scopus 로고
    • Resting technetium-99m tetrofosmin myocardial SPECT with and without attenuation correction for detecting viable myocardium: Comparison with FDG-PET
    • Matsunari I, Stollfuss J, Schneider-Eicke J, et al. Resting technetium-99m tetrofosmin myocardial SPECT with and without attenuation correction for detecting viable myocardium: comparison with FDG-PET [Abstract]. J Am Coll Cardiol 1996;27: 163A.
    • (1996) J Am Coll Cardiol , vol.27
    • Matsunari, I.1    Stollfuss, J.2    Schneider-Eicke, J.3
  • 6
    • 0018750969 scopus 로고
    • Analysis of probability as an aid in the clinical diagnosis of coronary artery disease
    • Diamond G, Forrester J. Analysis of probability as an aid in the clinical diagnosis of coronary artery disease. N Engl J Med 1979;300:283-298.
    • (1979) N Engl J Med , vol.300 , pp. 283-298
    • Diamond, G.1    Forrester, J.2
  • 7
    • 2642595134 scopus 로고
    • Attenuation correction for a multihead SPECT system: Initial validation
    • Boning G, Ficaro E, Nekolla S, et al. Attenuation correction for a multihead SPECT system: initial validation [abstract]. J Nucl Med 1995;36:11P.
    • (1995) J Nucl Med , vol.36
    • Boning, G.1    Ficaro, E.2    Nekolla, S.3
  • 8
    • 2642654319 scopus 로고
    • Simultaneous transmission/emission tomography using a line source with an off-center fanbeam collimator
    • Ficaro E, Hawman E, Schwaiger M. Simultaneous transmission/emission tomography using a line source with an off-center fanbeam collimator [Abstract]. J Nucl Med 1994;35:191P.
    • (1994) J Nucl Med , vol.35
    • Ficaro, E.1    Hawman, E.2    Schwaiger, M.3
  • 9
    • 0029017223 scopus 로고
    • Simultaneous transmission-emission thallium-201 cardiac SPECT: Effect of attenuation correction on myocardial tracer distribution
    • Ficaro EP, Fessier JA, Ackermann RJ, Rogers WL, Corbett JR, Schwaiger M. Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution. J Nucl Med 1995;36:921-931.
    • (1995) J Nucl Med , vol.36 , pp. 921-931
    • Ficaro, E.P.1    Fessier, J.A.2    Ackermann, R.J.3    Rogers, W.L.4    Corbett, J.R.5    Schwaiger, M.6
  • 10
    • 0028446166 scopus 로고
    • Penalized weighted least-squares image reconstruction for positron emission tomography
    • Fessier J. Penalized weighted least-squares image reconstruction for positron emission tomography. IEEE Trans Signal Proc 1993;13:290-300.
    • (1993) IEEE Trans Signal Proc , vol.13 , pp. 290-300
    • Fessier, J.1
  • 11
    • 0027211982 scopus 로고
    • An automated analysis program for the evaluation of cardiac PET studies: Initial results in the detection and localization of coronary artery disease using nitrogen-13-ammonia
    • Laubenbacher C, Rothley J, Sitomer J, et al. An automated analysis program for the evaluation of cardiac PET studies: initial results in the detection and localization of coronary artery disease using nitrogen-13-ammonia. J Nucl Med 1993;34:968-978.
    • (1993) J Nucl Med , vol.34 , pp. 968-978
    • Laubenbacher, C.1    Rothley, J.2    Sitomer, J.3
  • 12
    • 0027292105 scopus 로고
    • Effects of misalignment between transmission and emission scans on SPECT images
    • Murase K, Tanada S, Inoue T, Sugawara Y, Hamamoto K. Effects of misalignment between transmission and emission scans on SPECT images. J Nucl Med Technol 1993;21:152-156.
    • (1993) J Nucl Med Technol , vol.21 , pp. 152-156
    • Murase, K.1    Tanada, S.2    Inoue, T.3    Sugawara, Y.4    Hamamoto, K.5
  • 13
    • 0008295292 scopus 로고
    • Effects of attenuation scan misalignment in cardiac SPECT
    • Kemerink G, Bacharach S, Carson R. Effects of attenuation scan misalignment in cardiac SPECT [Abstract]. J Nucl Med 1990;31:875P.
    • (1990) J Nucl Med , vol.31
    • Kemerink, G.1    Bacharach, S.2    Carson, R.3
  • 14
    • 0029811098 scopus 로고    scopus 로고
    • Realignment of emission contaminated attenuation maps with uncontaminated attenuation maps for attenuation correction in PET
    • Buvat I, Freedman NM, Dilsizian V, Bacharach SL. Realignment of emission contaminated attenuation maps with uncontaminated attenuation maps for attenuation correction in PET. J Camp Assist Tomog 1996;20:848-854.
    • (1996) J Camp Assist Tomog , vol.20 , pp. 848-854
    • Buvat, I.1    Freedman, N.M.2    Dilsizian, V.3    Bacharach, S.L.4
  • 16
    • 0030951498 scopus 로고    scopus 로고
    • Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease
    • Prvulovich EM, Lonn AHR, Bomanji JB, Jarrit PH, Ell PJ. Effect of attenuation correction on myocardial thallium-201 distribution in patients with a low likelihood of coronary artery disease. Eur J Nucl Med 1997;24:266-275.
    • (1997) Eur J Nucl Med , vol.24 , pp. 266-275
    • Prvulovich, E.M.1    Lonn, A.H.R.2    Bomanji, J.B.3    Jarrit, P.H.4    Ell, P.J.5