메뉴 건너뛰기




Volumn 84, Issue 1, 1998, Pages 303-310

Anatomic distribution of pulmonary vascular compliance

Author keywords

Arterial occlusion; Digital image analysis; Double occlusion; Fluorescently labeled red blood cells; Isolated dog lung; Mathematical model; Pulmonary microcirculation; Vascular resistance; Venous occlusion; Video fluorescence microscopy

Indexed keywords

ANIMAL EXPERIMENT; ARTERY COMPLIANCE; ARTICLE; DOG; FLUORESCENCE MICROSCOPY; FUNCTIONAL ANATOMY; IMAGE ANALYSIS; LUNG ARTERY; LUNG BLOOD FLOW; LUNG CAPILLARY; LUNG CIRCULATION; LUNG VASCULAR RESISTANCE; LUNG VEIN; MALE; MATHEMATICAL MODEL; NONHUMAN; PRIORITY JOURNAL; VEIN COMPLIANCE; VIDEORECORDING;

EID: 2642644570     PISSN: 87507587     EISSN: None     Source Type: Journal    
DOI: 10.1152/jappl.1998.84.1.303     Document Type: Article
Times cited : (27)

References (21)
  • 1
    • 0026783832 scopus 로고
    • A method for analysis of pulmonary arterial and venous occlusion data
    • Audi, S. H., C. A. Dawson, and J. H. Linehan. A method for analysis of pulmonary arterial and venous occlusion data. J. Appl. Physiol. 73: 1190-1195, 1992.
    • (1992) J. Appl. Physiol. , vol.73 , pp. 1190-1195
    • Audi, S.H.1    Dawson, C.A.2    Linehan, J.H.3
  • 2
    • 0025736138 scopus 로고
    • Localization of the sites of pulmonary vasomotion by use of arterial and venous occlusion
    • Audi, S. H., C. A. Dawson, D. A. Rickaby, and J. H. Linehan. Localization of the sites of pulmonary vasomotion by use of arterial and venous occlusion. J. Appl. Physiol. 70: 2126-2136, 1991.
    • (1991) J. Appl. Physiol. , vol.70 , pp. 2126-2136
    • Audi, S.H.1    Dawson, C.A.2    Rickaby, D.A.3    Linehan, J.H.4
  • 3
    • 0022396635 scopus 로고
    • Limits on the continuous distribution of pulmonary vascular resistance versus compliance from outflow occlusion
    • Bronikowski, T. A., C. A. Dawson, and J. H. Linehan. Limits on the continuous distribution of pulmonary vascular resistance versus compliance from outflow occlusion. Microvasc. Res. 30: 306-313, 1985.
    • (1985) Microvasc. Res. , vol.30 , pp. 306-313
    • Bronikowski, T.A.1    Dawson, C.A.2    Linehan, J.H.3
  • 4
    • 0021680435 scopus 로고
    • A model of the vascular resistance and compliance distribution in a lung lobe
    • Bronikowski, T. A., J. H. Linehan, and C. A. Dawson. A model of the vascular resistance and compliance distribution in a lung lobe. Microvasc. Res. 28: 289-310, 1984.
    • (1984) Microvasc. Res. , vol.28 , pp. 289-310
    • Bronikowski, T.A.1    Linehan, J.H.2    Dawson, C.A.3
  • 8
    • 0028041275 scopus 로고
    • Vascular impedance analysis in dog lung with detailed morphometric and elasticity data
    • Gan, R. Z., and R. T. Yen. Vascular impedance analysis in dog lung with detailed morphometric and elasticity data. J. Appl. Physiol. 77: 706-717, 1994.
    • (1994) J. Appl. Physiol. , vol.77 , pp. 706-717
    • Gan, R.Z.1    Yen, R.T.2
  • 9
    • 0026021089 scopus 로고
    • Criteria for analysis of arterial and venous occlusion
    • Hakim, T. S. Criteria for analysis of arterial and venous occlusion. J. Appl. Physiol. 70: 665-675, 1991.
    • (1991) J. Appl. Physiol. , vol.70 , pp. 665-675
    • Hakim, T.S.1
  • 10
    • 0026764202 scopus 로고
    • Instant of vascular occlusion defined with laser-Doppler flowmetry
    • Hakim, T. S. Instant of vascular occlusion defined with laser-Doppler flowmetry. J. Appl. Physiol. 73: 284-289, 1992.
    • (1992) J. Appl. Physiol. , vol.73 , pp. 284-289
    • Hakim, T.S.1
  • 11
    • 0024342549 scopus 로고
    • Occlusion pressures vs. micropipette pressures in the pulmonary circulation
    • Hakim, T. S., and S. Kelly. Occlusion pressures vs. micropipette pressures in the pulmonary circulation. J. Appl. Physiol. 67: 1277-1285, 1989.
    • (1989) J. Appl. Physiol. , vol.67 , pp. 1277-1285
    • Hakim, T.S.1    Kelly, S.2
  • 12
    • 0019981273 scopus 로고
    • Partitioning of pulmonary vascular resistance in dogs by arterial and venous occlusion
    • Hakim, T. S., R. P. Michel, and H. K. Chang. Partitioning of pulmonary vascular resistance in dogs by arterial and venous occlusion. J. Appl. Physiol. 52: 710-715, 1982.
    • (1982) J. Appl. Physiol. , vol.52 , pp. 710-715
    • Hakim, T.S.1    Michel, R.P.2    Chang, H.K.3
  • 16
    • 0019947002 scopus 로고
    • Distribution of vascular resistance and compliance in a dog lung lobe
    • Linehan, J. H., C. A. Dawson, and D. A. Rickaby. Distribution of vascular resistance and compliance in a dog lung lobe. J. Appl. Physiol. 53: 158-168, 1982.
    • (1982) J. Appl. Physiol. , vol.53 , pp. 158-168
    • Linehan, J.H.1    Dawson, C.A.2    Rickaby, D.A.3
  • 17
    • 0029976354 scopus 로고    scopus 로고
    • Pulmonary capillary diameters and recruitment characteristics in subpleural and interior networks
    • Short, A. C., M. L. Montoya, S. A. Gebb, R. G. Presson, Jr., W. W. Wagner, Jr., and R. L. Capen. Pulmonary capillary diameters and recruitment characteristics in subpleural and interior networks. J. Appl. Physiol. 80: 1568-1573, 1996.
    • (1996) J. Appl. Physiol. , vol.80 , pp. 1568-1573
    • Short, A.C.1    Montoya, M.L.2    Gebb, S.A.3    Presson Jr., R.G.4    Wagner Jr., W.W.5    Capen, R.L.6
  • 18
    • 0022455987 scopus 로고
    • Validation of double vascular occlusion method for Pc in lung and skeletal muscle
    • Townsley, M. I., R. J. Korthuis, B. Rippe, J. C. Parker, and A. E. Taylor. Validation of double vascular occlusion method for Pc in lung and skeletal muscle. J. Appl. Physiol. 61: 127-132, 1986.
    • (1986) J. Appl. Physiol. , vol.61 , pp. 127-132
    • Townsley, M.I.1    Korthuis, R.J.2    Rippe, B.3    Parker, J.C.4    Taylor, A.E.5
  • 19
    • 0027261078 scopus 로고
    • Evaluation of carbocyanine-labeled erythrocytes for microvascular measurements
    • Unthank, J. L., J. M. Lash, J. C. Nixon, R. A. Sidner, and H. G. Bohlen. Evaluation of carbocyanine-labeled erythrocytes for microvascular measurements. Microvasc. Res. 45: 193-210, 1993.
    • (1993) Microvasc. Res. , vol.45 , pp. 193-210
    • Unthank, J.L.1    Lash, J.M.2    Nixon, J.C.3    Sidner, R.A.4    Bohlen, H.G.5
  • 20
    • 0014483762 scopus 로고
    • Pulmonary microcirculatory observations in vivo under physiological conditions
    • Wagner, W. W., Jr. Pulmonary microcirculatory observations in vivo under physiological conditions. J. Appl. Physiol. 26: 375-377, 1969.
    • (1969) J. Appl. Physiol. , vol.26 , pp. 375-377
    • Wagner Jr., W.W.1
  • 21
    • 78651150557 scopus 로고
    • Distribution of blood flow in isolated lung: Relation to vascular and alveolar pressures
    • West, J. B., C. T. Dollery, and A. Naimark. Distribution of blood flow in isolated lung: relation to vascular and alveolar pressures. J. Appl. Physiol. 19: 713-724, 1964.
    • (1964) J. Appl. Physiol. , vol.19 , pp. 713-724
    • West, J.B.1    Dollery, C.T.2    Naimark, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.