메뉴 건너뛰기




Volumn 34, Issue 2, 2004, Pages 135-143

New amperometric biosensors based on diamond paste for the assay of L- and D-pipecolic acids in serum samples

Author keywords

Amperometric biosensor; Clinical analysis; Enantioselective analysis; L(D) Aminoacid oxidase; L(D) Pipecolic acid; Monocrystalline diamond paste

Indexed keywords

BIOLOGICAL MARKER; DIAMOND; OIL; OXIDOREDUCTASE; PARAFFIN; PARAFFIN OILS; PIPECOLIC ACID; PIPECOLIC ACID DERIVATIVE;

EID: 2642586639     PISSN: 10826068     EISSN: None     Source Type: Journal    
DOI: 10.1081/PB-120030872     Document Type: Article
Times cited : (10)

References (15)
  • 1
    • 0032742427 scopus 로고    scopus 로고
    • Hyperpipecolic acidemia: Clinical, biomedical and radiologic observations
    • Al-Essa, M.; Chaves-Carballo, E.; Ozand, P.T. Hyperpipecolic acidemia: clinical, biomedical and radiologic observations. Pediatr. Neurol. 1999, 21, 826-829.
    • (1999) Pediatr. Neurol. , vol.21 , pp. 826-829
    • Al-Essa, M.1    Chaves-Carballo, E.2    Ozand, P.T.3
  • 2
    • 0032918335 scopus 로고    scopus 로고
    • Peroxisomal disorders: Clinical, biochemical and molecular aspects
    • Wanders, R.J.A. Peroxisomal disorders: clinical, biochemical and molecular aspects. Neurochem. Res. 1999, 24, 565-580.
    • (1999) Neurochem. Res. , vol.24 , pp. 565-580
    • Wanders, R.J.A.1
  • 4
    • 0036499918 scopus 로고    scopus 로고
    • Application of a new chiral derivatizing agent to the enantioseparation of secondary amino acids
    • Peter, A.; Vesek, E.; Toth, G.; Tourwe, D.; Borremans, F. Application of a new chiral derivatizing agent to the enantioseparation of secondary amino acids. J. Chromatogr. A 2002, 948, 283-294.
    • (2002) J. Chromatogr. A , vol.948 , pp. 283-294
    • Peter, A.1    Vesek, E.2    Toth, G.3    Tourwe, D.4    Borremans, F.5
  • 5
    • 0035197509 scopus 로고    scopus 로고
    • Determination of L-pipecolic acid in plasma using chiral liquid chromatography-electrospray tandem mass spectrometry
    • Rashed, M.S.; Al-Ahaidib, L.Y.; Aboul-Enein, H.Y.; Al-Amoundi, M.; Jacob, M. Determination of L-pipecolic acid in plasma using chiral liquid chromatography-electrospray tandem mass spectrometry. Clin. Chem. 2001, 47, 2124-2130.
    • (2001) Clin. Chem. , vol.47 , pp. 2124-2130
    • Rashed, M.S.1    Al-Ahaidib, L.Y.2    Aboul-Enein, H.Y.3    Al-Amoundi, M.4    Jacob, M.5
  • 6
    • 0042845491 scopus 로고
    • L-Porretine (L-3-carboxy-1,2,3,4-tetrahydroisoquinoline) as chiral selector for the resolution of chiral alpha amino acids
    • Jeanneret-Griss, G.; Porret, J.; Bernauer, K. L-Porretine (L-3-carboxy-1,2,3,4-tetrahydroisoquinoline) as chiral selector for the resolution of chiral alpha amino acids. Chromatogr. 1990, 29, 449-452.
    • (1990) Chromatogr. , vol.29 , pp. 449-452
    • Jeanneret-Griss, G.1    Porret, J.2    Bernauer, K.3
  • 7
    • 0035666650 scopus 로고    scopus 로고
    • Enantioseparation of chiral amino acids as the N(O,S)-ethoxycarbonylated diasteromeric esters by achiral dual-capillary column gas chromatography
    • Lee, J.; Kim, K.R.; Won, S.; Kim, J.H.; Goto, J. Enantioseparation of chiral amino acids as the N(O,S)-ethoxycarbonylated diasteromeric esters by achiral dual-capillary column gas chromatography. Analyst 2001, 126, 2128-2133.
    • (2001) Analyst , vol.126 , pp. 2128-2133
    • Lee, J.1    Kim, K.R.2    Won, S.3    Kim, J.H.4    Goto, J.5
  • 8
    • 0034644880 scopus 로고    scopus 로고
    • Enantioseparation of anionic analytes by non-aqueous capillary electrophoresis using quinine and quinidine derivatives as chiral counter-ions
    • Piette, V.; Lindner, W.; Crommen, J. Enantioseparation of anionic analytes by non-aqueous capillary electrophoresis using quinine and quinidine derivatives as chiral counter-ions. J. Chromatogr. A 2000, 894, 63-71.
    • (2000) J. Chromatogr. A , vol.894 , pp. 63-71
    • Piette, V.1    Lindner, W.2    Crommen, J.3
  • 9
    • 0027428141 scopus 로고
    • Reversed-phase thin layer chromatographic separations of enantiomers of dansylamino acids using 2-cyclodextrin as a mobile phase additive
    • Le Fevre, J.W. Reversed-phase thin layer chromatographic separations of enantiomers of dansylamino acids using 2-cyclodextrin as a mobile phase additive. J. Chromatogr. A 1993, 653, 293-302.
    • (1993) J. Chromatogr. A , vol.653 , pp. 293-302
    • Le Fevre, J.W.1
  • 11
    • 0142135891 scopus 로고    scopus 로고
    • Monocrystalline diamond paste based electrodes and their applications for the determination of Fe(II) in vitamins
    • in press
    • Stefan, R.I.; Bairu, S.G. Monocrystalline diamond paste based electrodes and their applications for the determination of Fe(II) in vitamins. Anal. Chem., in press.
    • Anal. Chem.
    • Stefan, R.I.1    Bairu, S.G.2
  • 12
    • 0642316361 scopus 로고    scopus 로고
    • Diamond paste based electrodes for the determination of Cr(III) in pharmaceutical compounds
    • Stefan, R.I.; Bairu, S.G.; van Staden, J.F. Diamond paste based electrodes for the determination of Cr(III) in pharmaceutical compounds. Anal. Bioanal. Chem. 2003, 376, 844-847.
    • (2003) Anal. Bioanal. Chem. , vol.376 , pp. 844-847
    • Stefan, R.I.1    Bairu, S.G.2    Van Staden, J.F.3
  • 13
    • 0038580680 scopus 로고    scopus 로고
    • Determinaton of creatine and creatinine using a diamond paste based electrode
    • Stefan, R.I.; Bokretsion, R.G. Determinaton of creatine and creatinine using a diamond paste based electrode. Instrum. Sci. & Technol. 2003, 31, 183-188.
    • (2003) Instrum. Sci. & Technol. , vol.31 , pp. 183-188
    • Stefan, R.I.1    Bokretsion, R.G.2
  • 14
    • 0001578691 scopus 로고
    • Selectivity coefficients for amperometric sensors
    • Wang, J. Selectivity coefficients for amperometric sensors. Talanta 1994, 41, 857-863.
    • (1994) Talanta , vol.41 , pp. 857-863
    • Wang, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.