메뉴 건너뛰기




Volumn 152, Issue 5, 2005, Pages 714-728

TCSC impact on communication-aided distance-protection schemes and its mitigation

Author keywords

[No Author keywords available]

Indexed keywords

DISTANCE-PROTECTION SCHEME; LOAD CURRENTS; PARAMETER IMPEDANCE; REAL-TIME DIGITAL SIMULATIONS;

EID: 26244447319     PISSN: 13502360     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1049/ip-gtd:20045261     Document Type: Article
Times cited : (53)

References (12)
  • 1
    • 1542322095 scopus 로고
    • Protection requirements for flexible AC transmission systems
    • Paris, France, paper 34-206
    • Adamiak, M., and Patterson, R.: 'Protection requirements for flexible AC transmission systems'. CIGRÉ Plenary Session, Paris, France, 1992, paper 34-206
    • (1992) CIGRÉ Plenary Session
    • Adamiak, M.1    Patterson, R.2
  • 3
    • 0037567275 scopus 로고    scopus 로고
    • An adaptive protection scheme for advanced series compensated (ASC) transmission lines
    • Girgis, A., Sallam, A., and El-Din, A.K.: 'An adaptive protection scheme for advanced series compensated (ASC) transmission lines', IEEE Trans., 1998, PWRD-13, pp. 414-420
    • (1998) IEEE Trans. , vol.PWRD-13 , pp. 414-420
    • Girgis, A.1    Sallam, A.2    El-Din, A.K.3
  • 4
    • 84979745186 scopus 로고    scopus 로고
    • The impact of TCSC on distance protection relay
    • 18-21 Aug.
    • Weiguo, W. et al.: 'The impact of TCSC on distance protection relay'. Proc. Int. Conf. Power System Technology, Powercon'98, 18-21 Aug. 1998, Vol. 1, pp. 382-388
    • (1998) Proc. Int. Conf. Power System Technology, Powercon'98 , vol.1 , pp. 382-388
    • Weiguo, W.1
  • 5
    • 26244449197 scopus 로고    scopus 로고
    • Real time digital simulator
    • Real time digital simulator, RSCAD', Ver. 1.177, 2003
    • (2003) RSCAD', Ver. 1.177
  • 6
    • 0028409456 scopus 로고    scopus 로고
    • Characteristics and rating considerations of thyristor controlled series compensation
    • Larsen, E.V., Clark, K., Miske, S.A. Jr., and Urbanek, J.: 'Characteristics and rating considerations of thyristor controlled series compensation', IEEE Trans. 1994, 2002, PWRD-9, (2), pp. 992-1000
    • (2002) IEEE Trans. 1994 , vol.PWRD-9 , Issue.2 , pp. 992-1000
    • Larsen, E.V.1    Clark, K.2    Miske Jr., S.A.3    Urbanek, J.4
  • 8
    • 0032627589 scopus 로고    scopus 로고
    • Using a miniature model and EMTP simulations to evaluate new methods to control and protect a thyristor-controlled series compensator
    • Tanaka, Y., Taniguchi, H., Tanaka, M.Y., Taniguchi, H., Egawa, M., Fujita, H., Watanabe, M., and Konishi, H.: 'Using a miniature model and EMTP simulations to evaluate new methods to control and protect a thyristor-controlled series compensator'. Presented at IEEE Winter Meeting, 1999
    • (1999) IEEE Winter Meeting
    • Tanaka, Y.1    Taniguchi, H.2    Tanaka, M.Y.3    Taniguchi, H.4    Egawa, M.5    Fujita, H.6    Watanabe, M.7    Konishi, H.8
  • 9
    • 0023670142 scopus 로고
    • A linearized model for MOV-protected series capacitors
    • Goldsworthy, D.L.: 'A linearized model for MOV-protected series capacitors', IEEE Trans., 1987, PWRS-2, (4), pp. 953-958
    • (1987) IEEE Trans. , vol.PWRS-2 , Issue.4 , pp. 953-958
    • Goldsworthy, D.L.1
  • 10
    • 26244459548 scopus 로고
    • The polarized mho distance relay
    • Wedepohl, L.M.: 'The polarized mho distance relay'. Proc. IEE, 1965, 122, pp. 525-535
    • (1965) Proc. IEE , vol.122 , pp. 525-535
    • Wedepohl, L.M.1
  • 12
    • 0010686220 scopus 로고    scopus 로고
    • IEC 61850:2003 (International Electrotechnical Commission, Geneva)
    • IEC 61850:2003: 'Communication networks and systems in substations' (International Electrotechnical Commission, Geneva, 2003)
    • (2003) Communication Networks and Systems in Substations