The effect of temperature elevation during discontinuous use of rotatory burrs in the correction of hallux valgus

Author keywords

Hallux valgus; Minimal incision surgery; Percutaneous osteotomy; Rotary burrs; Temperature

Indexed keywords

PARACETAMOL; SODIUM CHLORIDE;

EID: 26244440192     PISSN: 10672516     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.jfas.2005.07.009     Document Type: Article
Times cited : (14)

References (39)
  • 1
    • 0021685213 scopus 로고
    • The effect of heat on bone regeneration: An experimental study in the rabbit using the bone growth chamber
    • R.A. Eriksson, T. Albrektsson The effect of heat on bone regeneration an experimental study in the rabbit using the bone growth chamber J Oral Maxillofac Surg 42 1984 705 711
    • (1984) J Oral Maxillofac Surg , vol.42 , pp. 705-711
    • Eriksson, R.A.1    Albrektsson, T.2
  • 2
    • 0021704071 scopus 로고
    • Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals
    • R.A. Eriksson, T. Albrektsson, B. Albrektsson Heat caused by drilling cortical bone. Temperature measured in vivo in patients and animals Acta Orthop Scand 55 1984 629 631
    • (1984) Acta Orthop Scand , vol.55 , pp. 629-631
    • Eriksson, R.A.1    Albrektsson, T.2    Albrektsson, B.3
  • 3
    • 0021169798 scopus 로고
    • The thermal effects of skeletal fixation-pin insertion in bone
    • L.S. Matthews, C.A. Green, S.A. Goldstein The thermal effects of skeletal fixation-pin insertion in bone J Bone Joint Surg Am 66 1984 1077 1083
    • (1984) J Bone Joint Surg Am , vol.66 , pp. 1077-1083
    • Matthews, L.S.1    Green, C.A.2    Goldstein, S.A.3
  • 4
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • L.S. Matthews, C. Hirsch Temperatures measured in human cortical bone when drilling J Bone Joint Surg Am 54 1972 297 308
    • (1972) J Bone Joint Surg Am , vol.54 , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 5
    • 0025082453 scopus 로고
    • An internally cooled saw blade for bone cuts. Lower temperatures in 30 knee arthroplasties
    • S. Toksvig-Larsen, L. Ryd, A. Lindstrand An internally cooled saw blade for bone cuts. Lower temperatures in 30 knee arthroplasties Acta Orthop Scand 61 1990 321 323
    • (1990) Acta Orthop Scand , vol.61 , pp. 321-323
    • Toksvig-Larsen, S.1    Ryd, L.2    Lindstrand, A.3
  • 6
    • 0015466880 scopus 로고
    • Influence of temperature on the compact bone substance during drilling, thread cutting and insertion of bone screws
    • J. Eichler, R. Berg Influence of temperature on the compact bone substance during drilling, thread cutting and insertion of bone screws Z Orthop Ihre Grenzgeb 110 1972 909 913
    • (1972) Z Orthop Ihre Grenzgeb , vol.110 , pp. 909-913
    • Eichler, J.1    Berg, R.2
  • 7
    • 0037946980 scopus 로고    scopus 로고
    • Temperature changes induced by 809-nm GaA1As laser at the implant-bone interface during simulated surface decontamination
    • M. Kreisler, H. Al Haj, B. D'Hoedt Temperature changes induced by 809-nm GaA1As laser at the implant-bone interface during simulated surface decontamination Clin Oral Implants Res 14 2003 91 96
    • (2003) Clin Oral Implants Res , vol.14 , pp. 91-96
    • Kreisler, M.1    Al Haj, H.2    D'Hoedt, B.3
  • 8
    • 0026198363 scopus 로고    scopus 로고
    • Bone growth around dental implants
    • M. Weinlaender Bone growth around dental implants Dent Clin North Am 35 1999 585 601
    • (1999) Dent Clin North Am , vol.35 , pp. 585-601
    • Weinlaender, M.1
  • 9
    • 0029683215 scopus 로고    scopus 로고
    • The effect of speed, pressure, and time on bone temperature during the drilling of implant sites
    • D.L. Brisman The effect of speed, pressure, and time on bone temperature during the drilling of implant sites Int J Oral Maxillofac Implants 11 1996 35 37
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 35-37
    • Brisman, D.L.1
  • 10
    • 0000714284 scopus 로고
    • Temperature changes during high-speed drilling on bone
    • S.S. Rafel Temperature changes during high-speed drilling on bone J Oral Surg Anesth Hosp Dent Serv 20 1962 475 477
    • (1962) J Oral Surg Anesth Hosp Dent Serv , vol.20 , pp. 475-477
    • Rafel, S.S.1
  • 11
    • 0017835876 scopus 로고
    • Thermal injury from mastoid bone burrs
    • W.H. Call Thermal injury from mastoid bone burrs Ann Otol Rhinol Laryngol 87 1978 43 49
    • (1978) Ann Otol Rhinol Laryngol , vol.87 , pp. 43-49
    • Call, W.H.1
  • 12
    • 0029135259 scopus 로고
    • Thermal response and torque resistance of five cortical half-pins under simulated insertion technique
    • M.A. Wikenheiser, M.D. Markel, D.G. Leallen, E.Y. Chao Thermal response and torque resistance of five cortical half-pins under simulated insertion technique J Orthop Res 13 1995 615 619
    • (1995) J Orthop Res , vol.13 , pp. 615-619
    • Wikenheiser, M.A.1    Markel, M.D.2    Leallen, D.G.3    Chao, E.Y.4
  • 13
    • 0029683215 scopus 로고    scopus 로고
    • The effect of speed, pressure, and time on bone temperature during the drilling of implant sites
    • D.L. Brisman The effect of speed, pressure, and time on bone temperature during the drilling of implant sites Int J Oral Maxillofac Implants 11 1996 35 37
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 35-37
    • Brisman, D.L.1
  • 15
    • 0031088297 scopus 로고    scopus 로고
    • Heat generation during implant site preparation: An in vitro study
    • G. Cordioli, Z. Majzoub Heat generation during implant site preparation an in vitro study Int J Oral Maxillofac Implants 12 1997 186 193
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 186-193
    • Cordioli, G.1    Majzoub, Z.2
  • 16
    • 3042517588 scopus 로고    scopus 로고
    • The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: A study of drill durability
    • C. Ercoli, P.D. Funkenbusch, H.J. Lee, M.E. Moss, G.N. Graser The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants a study of drill durability Int J Oral Maxillofac Implants 19 2004 335 349
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 335-349
    • Ercoli, C.1    Funkenbusch, P.D.2    Lee, H.J.3    Moss, M.E.4    Graser, G.N.5
  • 17
    • 0029890494 scopus 로고    scopus 로고
    • Orthopaedic bone drills-can be improved? Temperature changes near the drilling face
    • C. Natali, P. Ingle, J. Dowell Orthopaedic bone drills-can be improved? Temperature changes near the drilling face J Bone Joint Surg Br 78 1996 357 362
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 357-362
    • Natali, C.1    Ingle, P.2    Dowell, J.3
  • 18
    • 26244466288 scopus 로고    scopus 로고
    • Heat generation during ulnar osteotomy with microsagittal saw blades
    • K. Firoozbakhsh, M.S. Moneim, E. Mikola, S. Halton Heat generation during ulnar osteotomy with microsagittal saw blades Iowa Orthop J 23 2003 46 50
    • (2003) Iowa Orthop J , vol.23 , pp. 46-50
    • Firoozbakhsh, K.1    Moneim, M.S.2    Mikola, E.3    Halton, S.4
  • 19
    • 0031152012 scopus 로고    scopus 로고
    • Influence of different parameters on bone heating and drilling time in implantology
    • Y. Reigenwirtz, S. Szmukler-Moncler, B. Senger Influence of different parameters on bone heating and drilling time in implantology Clin Oral Implants Res 8 1997 189 197
    • (1997) Clin Oral Implants Res , vol.8 , pp. 189-197
    • Reigenwirtz, Y.1    Szmukler-Moncler, S.2    Senger, B.3
  • 20
    • 0036788376 scopus 로고    scopus 로고
    • Heat generation during implant drilling: The significance of motor speed
    • M. Sharawy, C.E. Misch, N. Weller, S. Tehemar Heat generation during implant drilling the significance of motor speed J Oral Maxillofac Surg 60 2002 1160 1169
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 1160-1169
    • Sharawy, M.1    Misch, C.E.2    Weller, N.3    Tehemar, S.4
  • 21
    • 0032928957 scopus 로고    scopus 로고
    • Future directions in innovative minimally invasive surgery
    • D.W. Rattner Future directions in innovative minimally invasive surgery Lancet 353 Suppl 1 1999 SI12 SI15
    • (1999) Lancet , vol.353 , Issue.SUPPL. 1
    • Rattner, D.W.1
  • 23
    • 0026553813 scopus 로고
    • Minimal incision surgery
    • D.E. Chalk, G.J. Sammarco Minimal incision surgery Foot Ankle 13 1992 157 160
    • (1992) Foot Ankle , vol.13 , pp. 157-160
    • Chalk, D.E.1    Sammarco, G.J.2
  • 24
    • 0026098943 scopus 로고
    • Complications in minimal incision surgery
    • M.G. Solomon Complications in minimal incision surgery Clin Podiatr Med Surg 8 1991 221 242
    • (1991) Clin Podiatr Med Surg , vol.8 , pp. 221-242
    • Solomon, M.G.1
  • 25
    • 0025967437 scopus 로고
    • The Reverdin-Isham procedure for the correction of hallux abducto valgus. a distal metatarsal osteotomy procedure
    • S.A. Isham The Reverdin-Isham procedure for the correction of hallux abducto valgus. A distal metatarsal osteotomy procedure Clin Podiatr Med Surg 8 1991 81 94
    • (1991) Clin Podiatr Med Surg , vol.8 , pp. 81-94
    • Isham, S.A.1
  • 30
    • 0032601842 scopus 로고    scopus 로고
    • Factors affecting heat generation during implant site preparation: A review of biologic observations and future considerations
    • S.H. Tehemar Factors affecting heat generation during implant site preparation a review of biologic observations and future considerations Int J Oral Maxillofac Implants 14 1999 127 136
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 127-136
    • Tehemar, S.H.1
  • 32
    • 26244445697 scopus 로고
    • The temperature dependence of the deformation of bone
    • W. Bonfield, C.H. Li The temperature dependence of the deformation of bone J Biomech 25 1992 11 16
    • (1992) J Biomech , vol.25 , pp. 11-16
    • Bonfield, W.1    Li, C.H.2
  • 33
    • 0030236835 scopus 로고    scopus 로고
    • The effect of irrigation on osteotomy depth and bur diameter
    • M.J. Yacker, M. Klein The effect of irrigation on osteotomy depth and bur diameter Int J Oral Maxillofac Implants 11 1996 634 638
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 634-638
    • Yacker, M.J.1    Klein, M.2
  • 35
    • 0020322562 scopus 로고
    • Thermal injury to bone. a vital-microscopic description of heat effects
    • R.A. Eriksson, T. Albrektsson, B. Grane, D. McQueen Thermal injury to bone. A vital-microscopic description of heat effects Int J Oral Surg 11 1982 115 121
    • (1982) Int J Oral Surg , vol.11 , pp. 115-121
    • Eriksson, R.A.1    Albrektsson, T.2    Grane, B.3    McQueen, D.4
  • 37
    • 0016300904 scopus 로고
    • Development of raised temperature after osteotomies
    • P. Tetsch Development of raised temperature after osteotomies J Maxillofac Surg 2 1974 141 145
    • (1974) J Maxillofac Surg , vol.2 , pp. 141-145
    • Tetsch, P.1
  • 38
    • 0031836053 scopus 로고    scopus 로고
    • The influence of active shear or compressive motion on fracture-healing
    • S.H. Park, K. O'Connor, H. McKellop, A. Sarmiento The influence of active shear or compressive motion on fracture-healing J Bone Joint Surg Am 80 1998 868 878
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 868-878
    • Park, S.H.1    O'Connor, K.2    McKellop, H.3    Sarmiento, A.4
  • 39
    • 0034797499 scopus 로고    scopus 로고
    • Complications after surgery of the hallux
    • G.J. Sammarco, O.B. Idusuyi Complications after surgery of the hallux Clin Orthop Oct 391 2001 59 71
    • (2001) Clin Orthop Oct , vol.391 , pp. 59-71
    • Sammarco, G.J.1    Idusuyi, O.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.