메뉴 건너뛰기




Volumn 27, Issue 2, 2005, Pages 89-100

Catheter ultrasound phased-array transducers for thermal ablation: A feasibility study

Author keywords

Catheter transducer; Ultrasound ablation

Indexed keywords

ABLATION; CATHETERS; SCANNING; TISSUE; ULTRASONIC TRANSDUCERS;

EID: 26044464216     PISSN: 01617346     EISSN: None     Source Type: Journal    
DOI: 10.1177/016173460502700203     Document Type: Article
Times cited : (7)

References (19)
  • 2
    • 0034107814 scopus 로고    scopus 로고
    • Novel catheter technology for ablative cure of atrial fibrillation
    • Lesh MD, Guerra PG, Roithinger FX, et al. Novel catheter technology for ablative cure of atrial fibrillation, J Interv Card Electr 4, 127-139 (2000).
    • (2000) J Interv Card Electr , vol.4 , pp. 127-139
    • Lesh, M.D.1    Guerra, P.G.2    Roithinger, F.X.3
  • 3
    • 0030106206 scopus 로고    scopus 로고
    • Ablation for the treatment of arrhythmias
    • McRury ID, Haines DE. Ablation for the treatment of arrhythmias, Proc IEEE 84, 404-416 (1996).
    • (1996) Proc IEEE , vol.84 , pp. 404-416
    • McRury, I.D.1    Haines, D.E.2
  • 4
    • 0037532650 scopus 로고    scopus 로고
    • Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein
    • Meininger GR, Calkins H, Lickfett L, et al. Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein, J Interven Cardiac Electrophys 8, 41-148 (2003).
    • (2003) J Interven Cardiac Electrophys , vol.8 , pp. 41-148
    • Meininger, G.R.1    Calkins, H.2    Lickfett, L.3
  • 5
    • 0034579249 scopus 로고    scopus 로고
    • Transurethral high intensity focused ultrasound: Catheter based prototypes and experimental results
    • IEEE cat. no. 00CH37121
    • Seip R, Biswas M, Kuznetsov M, Sanghvi N. Transurethral high intensity focused ultrasound: catheter based prototypes and experimental results, in Proc IEEE Ultrasonics Symp, pp. 1413-1416 (IEEE cat. no. 00CH37121, 2000).
    • (2000) Proc IEEE Ultrasonics Symp , pp. 1413-1416
    • Seip, R.1    Biswas, M.2    Kuznetsov, M.3    Sanghvi, N.4
  • 6
    • 0042859965 scopus 로고    scopus 로고
    • Combined 3-D intracardiac echo and ultrasound ablation
    • SPIE cat. no. 5035
    • Gentry KL, Light ED, Smith SW. Combined 3-D intracardiac echo and ultrasound ablation, in Proc SPIE Medical Imaging, pp. 166-173 (SPIE cat. no. 5035, 2003).
    • (2003) Proc SPIE Medical Imaging , pp. 166-173
    • Gentry, K.L.1    Light, E.D.2    Smith, S.W.3
  • 7
    • 4143147547 scopus 로고    scopus 로고
    • Integrated catheter for 3-D intracardiac echocardiography and ultrasound ablation
    • IEEE cat. no. 03CH37476
    • Gentry KL, Smith SW. Integrated catheter for 3-D intracardiac echocardiography and ultrasound ablation, in Proc IEEE Ultrasonics Symp, pp. 1099-1102 (IEEE cat. no. 03CH37476, 2003).
    • (2003) Proc IEEE Ultrasonics Symp , pp. 1099-1102
    • Gentry, K.L.1    Smith, S.W.2
  • 8
    • 3142671921 scopus 로고    scopus 로고
    • Integrated catheter for 3-D intracardiac echocardiography and ultrasound ablation
    • Gentry KL, Smith SW. Integrated catheter for 3-D intracardiac echocardiography and ultrasound ablation, IEEE Trans Ultrason Ferroelec Freq Contr 51, 800-808 (2004).
    • (2004) IEEE Trans Ultrason Ferroelec Freq Contr , vol.51 , pp. 800-808
    • Gentry, K.L.1    Smith, S.W.2
  • 9
    • 0030803344 scopus 로고    scopus 로고
    • Electrophysiological effects of long, linear atrial lesions placed under intracardiac ultrasound guidance
    • Olgin JE, Kalman JM, Chin M, et al. Electrophysiological effects of long, linear atrial lesions placed under intracardiac ultrasound guidance, Circulation 96, 2715-2721 (1997).
    • (1997) Circulation , vol.96 , pp. 2715-2721
    • Olgin, J.E.1    Kalman, J.M.2    Chin, M.3
  • 11
    • 0141638528 scopus 로고    scopus 로고
    • Dual lumen transducer probes for real-time 3-D interventional cardiac ultrasound
    • Lee W, Idriss SF, WoIfPD, Smith SW. Dual lumen transducer probes for real-time 3-D interventional cardiac ultrasound, Ultrasound Med Biol 29, 1297-1304 (2003).
    • (2003) Ultrasound Med Biol , vol.29 , pp. 1297-1304
    • Lee, W.1    Idriss, S.F.2    WoIf, P.D.3    Smith, S.W.4
  • 12
    • 0029274335 scopus 로고
    • Evaluation of accuracy of a theoretical model for predicting the necrosed tissue volume during focused ultrasound surgery
    • Damianou CA, Hynynen K, Fan X. Evaluation of accuracy of a theoretical model for predicting the necrosed tissue volume during focused ultrasound surgery, IEEE Trans Ultrason Ferroelec Freq Contr 42, 182-187 (1995).
    • (1995) IEEE Trans Ultrason Ferroelec Freq Contr , vol.42 , pp. 182-187
    • Damianou, C.A.1    Hynynen, K.2    Fan, X.3
  • 13
    • 0021277965 scopus 로고
    • Thermal dose determination in cancer therapy
    • Sapareto SA, Dewey WC. Thermal dose determination in cancer therapy, Int J Radiat Oncol 10, 787-800 (1984).
    • (1984) Int J Radiat Oncol , vol.10 , pp. 787-800
    • Sapareto, S.A.1    Dewey, W.C.2
  • 14
    • 0026128882 scopus 로고
    • High-speed ultrasound volumetric imaging system - Part I: Transducer design and beam steering
    • Smith SW, Pavy HG, von Ramm OT. High-speed ultrasound volumetric imaging system - part I: transducer design and beam steering, IEEE Trans Ultrason Ferroelec Freq Contr 38, 100-108 (1991).
    • (1991) IEEE Trans Ultrason Ferroelec Freq Contr , vol.38 , pp. 100-108
    • Smith, S.W.1    Pavy, H.G.2    Von Ramm, O.T.3
  • 15
    • 0026128878 scopus 로고
    • High-speed ultrasound volumetric imaging system - Part II: Parallel processing and image display
    • von Ramm OT, Smith SW, Pavy HG. High-speed ultrasound volumetric imaging system - part II: parallel processing and image display, IEEE Trans Ultrason Ferroelec Freq Contr 38, 109-115 (1991).
    • (1991) IEEE Trans Ultrason Ferroelec Freq Contr , vol.38 , pp. 109-115
    • Von Ramm, O.T.1    Smith, S.W.2    Pavy, H.G.3
  • 16
    • 0033295064 scopus 로고    scopus 로고
    • Update of two dimensional arrays for real time volumetric imaging and real time intracardiac imaging
    • IEEE cat. no. 99CH37027
    • Light ED, Fiering JO, Hultman PA, Lee W, Smith SW. Update of two dimensional arrays for real time volumetric imaging and real time intracardiac imaging, in Proc IEEE Ultrasonics Symp, pp. 1217-1220 (IEEE cat. no. 99CH37027, 1999).
    • (1999) Proc IEEE Ultrasonics Symp , pp. 1217-1220
    • Light, E.D.1    Fiering, J.O.2    Hultman, P.A.3    Lee, W.4    Smith, S.W.5
  • 17
    • 0014796286 scopus 로고
    • New equivalent circuits for elementary piezoelectric transducers
    • Krimholtz R, Leedom DA, Matthaei GL. New equivalent circuits for elementary piezoelectric transducers, Electron Lett 6, pp. 398-399 (1970).
    • (1970) Electron Lett , vol.6 , pp. 398-399
    • Krimholtz, R.1    Leedom, D.A.2    Matthaei, G.L.3
  • 19
    • 0026838720 scopus 로고
    • Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
    • Jensen JA, Svendsen NB. Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers, IEEE Trans Ultrason Ferroelec Freq Contr 39 (1992).
    • (1992) IEEE Trans Ultrason Ferroelec Freq Contr , vol.39
    • Jensen, J.A.1    Svendsen, N.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.