메뉴 건너뛰기




Volumn 18, Issue 3, 2005, Pages 311-324

Comparison of cascade impaction and laser diffraction for particle size distribution measurements

Author keywords

Impactor; Laser diffraction; Particle size distribution; Soft mist inhaler

Indexed keywords

AEROSOL; ANALYZER; ARTICLE; COMPARATIVE STUDY; DRUG FORMULATION; ENVIRONMENTAL TEMPERATURE; EVAPORATION; FLOW RATE; HUMIDITY; LASER DIFFRACTION; MEASUREMENT; METERED DOSE INHALER; PARTICLE SIZE; TECHNIQUE;

EID: 25844507063     PISSN: 08942684     EISSN: None     Source Type: Journal    
DOI: 10.1089/jam.2005.18.311     Document Type: Article
Times cited : (43)

References (18)
  • 1
    • 25844477010 scopus 로고    scopus 로고
    • USP 26. 2003. U.S. Pharmacopeial Convention, Inc. Particle Size 2110-2123. Webcom Ltd., Toronto
    • USP 26. 2003. U.S. Pharmacopeial Convention, Inc. Particle Size 2110-2123. Webcom Ltd., Toronto.
  • 4
    • 0028954464 scopus 로고
    • The use of laser diffraction for the evaluation of the aerosol clouds generated by medical nebulizers
    • Clark, A.R. 1995. The use of laser diffraction for the evaluation of the aerosol clouds generated by medical nebulizers. Int. J. Pharm. 115:69-78
    • (1995) Int. J. Pharm. , vol.115 , pp. 69-78
    • Clark, A.R.1
  • 5
    • 0034492461 scopus 로고    scopus 로고
    • Comparison of nebulized particle size distribution with Malvem laser diffraction analyser versus Andersen cascade impactor and low-flow Marple personal cascade impactor
    • Kwong, W.T.J., S.L. Ho, and A.L. Coates. 2000. Comparison of nebulized particle size distribution with Malvem laser diffraction analyser versus Andersen cascade impactor and low-flow Marple personal cascade impactor. J. Aerosol Med. 13:303-314.
    • (2000) J. Aerosol Med. , vol.13 , pp. 303-314
    • Kwong, W.T.J.1    Ho, S.L.2    Coates, A.L.3
  • 6
    • 0035008993 scopus 로고    scopus 로고
    • Validation of laser diffraction method as a substitute for cascade impaction in the European project for a nebulizer standard
    • Vecellio None, L., D. Grimbert, M.H. Bequemin, et al. 2001. Validation of laser diffraction method as a substitute for cascade impaction in the European project for a nebulizer standard. J. Aerosol Med. 14:107-114.
    • (2001) J. Aerosol Med. , vol.14 , pp. 107-114
    • Vecellio None, L.1    Grimbert, D.2    Bequemin, M.H.3
  • 8
    • 25844450035 scopus 로고    scopus 로고
    • Particle size measurement techniques for pharmaceutical device development
    • Ziegler, J., and H. Wachtel. 2001. Particle size measurement techniques for pharmaceutical device development. Drug Deliv. Lungs XII 54-57.
    • (2001) Drug Deliv. Lungs XII , pp. 54-57
    • Ziegler, J.1    Wachtel, H.2
  • 9
    • 4444254594 scopus 로고    scopus 로고
    • Improved assessment of inhaler device performance using laser diffraction
    • Wachtel, H., and J. Ziegler. 2002. Improved assessment of inhaler device performance using laser diffraction. Respir. Drug Deliv. VIII 379-381.
    • (2002) Respir. Drug Deliv. VIII , pp. 379-381
    • Wachtel, H.1    Ziegler, J.2
  • 11
    • 0028423222 scopus 로고
    • Droplet size distribution measurements for medical nebulizers by the forward light scattering technique
    • Merkus, H.G., J.C.M. Marijnissen, E.H.L. Jansma, et al. 1994. Droplet size distribution measurements for medical nebulizers by the forward light scattering technique. J. Aerosol Sci. 25:S319-S320.
    • (1994) J. Aerosol Sci. , vol.25
    • Merkus, H.G.1    Marijnissen, J.C.M.2    Jansma, E.H.L.3
  • 12
    • 0033990466 scopus 로고    scopus 로고
    • Optical measurement of nebulizer sprays: A quantitative comparison of diffraction, phase doppler interferometry, and time of flight techniques
    • Corcoran, T.E., R. Hitron, W. Humphrey, et al. 2000. Optical measurement of nebulizer sprays: a quantitative comparison of diffraction, phase doppler interferometry, and time of flight techniques. J. Aerosol Sci. 31:35-50.
    • (2000) J. Aerosol Sci. , vol.31 , pp. 35-50
    • Corcoran, T.E.1    Hitron, R.2    Humphrey, W.3
  • 14
    • 0343090817 scopus 로고    scopus 로고
    • Reticles as standards in laser diffraction spectroscopy
    • Mühlenweg, H., and E.D. Hirleman. 1999. Reticles as standards in laser diffraction spectroscopy. Part. Part. Syst. Charact. 16:47-53.
    • (1999) Part. Part. Syst. Charact. , vol.16 , pp. 47-53
    • Mühlenweg, H.1    Hirleman, E.D.2
  • 15
    • 1642578544 scopus 로고    scopus 로고
    • Andersen cascade impactor: Calibration and mensuration issues for the standard and modified impactor
    • Nichols, S.C. 2000. Andersen cascade impactor: calibration and mensuration issues for the standard and modified impactor. PharmEuropa 12:584-588.
    • (2000) PharmEuropa , vol.12 , pp. 584-588
    • Nichols, S.C.1
  • 16
    • 0024867672 scopus 로고
    • The Andersen impactor: Calibration, wall losses and numerical simulation
    • Vaughan, N.P. 1989. The Andersen impactor: calibration, wall losses and numerical simulation. J. Aerosol Sci. 20:67-90.
    • (1989) J. Aerosol Sci. , vol.20 , pp. 67-90
    • Vaughan, N.P.1
  • 17
    • 0037305631 scopus 로고    scopus 로고
    • A comparison of cascade impactor data reduction methods
    • O'Shaughnessy, P.T., and O.G. Raabe. 2003. A comparison of cascade impactor data reduction methods. J. Aerosol Sci. Technol. 37:187-200.
    • (2003) J. Aerosol Sci. Technol. , vol.37 , pp. 187-200
    • O'Shaughnessy, P.T.1    Raabe, O.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.