메뉴 건너뛰기




Volumn 40, Issue 10, 2005, Pages 682-687

Evaluation of testicular viability by power Doppler ultrasonography in experimentally induced acute testicular torsion

Author keywords

Power Doppler studies; Testis; Torsion; US ultrasound (US)

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; DIAGNOSTIC IMAGING; DOPPLER ECHOGRAPHY; EXPERIMENTAL MODEL; HISTOPATHOLOGY; MALE; NONHUMAN; ORCHIDOPEXY; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RAT; TESTIS BLOOD FLOW; TESTIS TORSION; ULTRASOUND;

EID: 25644440841     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000178837.68891.f2     Document Type: Article
Times cited : (9)

References (27)
  • 1
    • 0028257981 scopus 로고
    • Variability of ischemia during spermatic cord torsion in the rat
    • Costabile RA, Choyke PL, Frank JA, et al. Variability of ischemia during spermatic cord torsion in the rat. J Urol. 1994;151:1070-1072.
    • (1994) J Urol , vol.151 , pp. 1070-1072
    • Costabile, R.A.1    Choyke, P.L.2    Frank, J.A.3
  • 2
    • 0029947358 scopus 로고    scopus 로고
    • Acute testicular torsion: Comparison of unenhanced and contrast-enhanced power Doppler US, color Doppler US, and radionuclide imaging
    • Coley BD, Frush DP, Babcock DS, et al. Acute testicular torsion: comparison of unenhanced and contrast-enhanced power Doppler US, color Doppler US, and radionuclide imaging. Radiology. 1996;199:441-446.
    • (1996) Radiology , vol.199 , pp. 441-446
    • Coley, B.D.1    Frush, D.P.2    Babcock, D.S.3
  • 3
    • 0028821496 scopus 로고
    • Evaluation of acute scrotum in the emergency department
    • Lewis AG, Bukowski TP, Jarvis PD, et al. Evaluation of acute scrotum in the emergency department. J Pediatr Surg. 1995;30:277-281.
    • (1995) J Pediatr Surg , vol.30 , pp. 277-281
    • Lewis, A.G.1    Bukowski, T.P.2    Jarvis, P.D.3
  • 4
    • 0017813059 scopus 로고
    • Torsion of spermatic cord
    • Donohue RE, Utley WLF. Torsion of spermatic cord. J Urol. 1978;40: 33-36.
    • (1978) J Urol , vol.40 , pp. 33-36
    • Donohue, R.E.1    Utley, W.L.F.2
  • 5
    • 0026000967 scopus 로고
    • Testicular scanning: Evaluation the acute scrotum in the clinical setting
    • Fenner MN, Roszhart DA, Texter JH. Testicular scanning: evaluation the acute scrotum in the clinical setting. Urology. 1991;38:237-241.
    • (1991) Urology , vol.38 , pp. 237-241
    • Fenner, M.N.1    Roszhart, D.A.2    Texter, J.H.3
  • 6
    • 0024005897 scopus 로고
    • Old and new aspects of testicular torsion
    • Workman SJ, Kogan BA. Old and new aspects of testicular torsion. Semin Urol. 1988;6:146-157.
    • (1988) Semin Urol , vol.6 , pp. 146-157
    • Workman, S.J.1    Kogan, B.A.2
  • 7
    • 0001029943 scopus 로고
    • Cellular changes from graded testicular ischemia
    • Smith GI. Cellular changes from graded testicular ischemia. J Urol. 1955;73:355-362.
    • (1955) J Urol , vol.73 , pp. 355-362
    • Smith, G.I.1
  • 8
    • 0020442773 scopus 로고
    • The effect of testicular torsion on the contralateral testis
    • Nagler HM, White RD. The effect of testicular torsion on the contralateral testis. J Urol. 1982;128:1343-1348.
    • (1982) J Urol , vol.128 , pp. 1343-1348
    • Nagler, H.M.1    White, R.D.2
  • 9
    • 0031024197 scopus 로고    scopus 로고
    • Sonographic prediction of viability in testicular torsion: Preliminary observation
    • Middleton WD, Middleton MA, Dierks M, et al. Sonographic prediction of viability in testicular torsion: preliminary observation. J Ultrasound Med. 1997;16:23-27.
    • (1997) J Ultrasound Med , vol.16 , pp. 23-27
    • Middleton, W.D.1    Middleton, M.A.2    Dierks, M.3
  • 10
    • 0025100551 scopus 로고
    • Acute scrotal disorder: Prospective comparison of color Doppler US and testicular scintigraphy
    • Middleton WD, Siegel BA, Melson GL, et al. Acute scrotal disorder: prospective comparison of color Doppler US and testicular scintigraphy. Radiology. 1990;177:177-181.
    • (1990) Radiology , vol.177 , pp. 177-181
    • Middleton, W.D.1    Siegel, B.A.2    Melson, G.L.3
  • 11
    • 0032118967 scopus 로고    scopus 로고
    • Diagnostic imaging for pediatric scrotal disorders
    • Frush DP, Sheldon CA. Diagnostic imaging for pediatric scrotal disorders. Radiographics. 1998;18:969-985.
    • (1998) Radiographics , vol.18 , pp. 969-985
    • Frush, D.P.1    Sheldon, C.A.2
  • 12
    • 0026608429 scopus 로고
    • The normal and abnormal scrotum in children: Evaluation with color Doppler sonography
    • Atkinson GO, Patrick LE, Ball TI, et al. The normal and abnormal scrotum in children: evaluation with color Doppler sonography. AJR Am J Roentgenol. 1992;158:613-617.
    • (1992) AJR Am J Roentgenol , vol.158 , pp. 613-617
    • Atkinson, G.O.1    Patrick, L.E.2    Ball, T.I.3
  • 13
    • 0032101967 scopus 로고    scopus 로고
    • Testicular torsion in neonates: Importance of power Doppler imaging
    • Harry LZ, Harris LC, Mark H. Testicular torsion in neonates: importance of power Doppler imaging. J Ultrasound Med. 1998;17:385-388.
    • (1998) J Ultrasound Med , vol.17 , pp. 385-388
    • Harry, L.Z.1    Harris, L.C.2    Mark, H.3
  • 14
    • 0030066590 scopus 로고    scopus 로고
    • Scrotal US in pediatric patients: Comparison of power and standard color Doppler US
    • Luker GD, Siegel MJ. Scrotal US in pediatric patients: comparison of power and standard color Doppler US. Radiology. 1996;198:381-385.
    • (1996) Radiology , vol.198 , pp. 381-385
    • Luker, G.D.1    Siegel, M.J.2
  • 15
    • 0030046386 scopus 로고    scopus 로고
    • Power Doppler sonography: Basic principles and clinical applications in children
    • Babcock DS, Patriquin H, LaFortune M, et al. Power Doppler sonography: basic principles and clinical applications in children. Pediatr Radiol. 1996;26:109-115.
    • (1996) Pediatr Radiol , vol.26 , pp. 109-115
    • Babcock, D.S.1    Patriquin, H.2    Lafortune, M.3
  • 16
    • 0025329261 scopus 로고
    • Suspected testicular torsion and ischemia: Evaluation with color Doppler sonography
    • Burks DD, Markey BJ, Burkhardt TK, et al. Suspected testicular torsion and ischemia: evaluation with color Doppler sonography. Radiology. 1990;175:815-821.
    • (1990) Radiology , vol.175 , pp. 815-821
    • Burks, D.D.1    Markey, B.J.2    Burkhardt, T.K.3
  • 17
    • 0026326017 scopus 로고
    • Color-coded duplex sonography for diagnosis of testicular torsion
    • Zoeller G, Ringer RH. Color-coded duplex sonography for diagnosis of testicular torsion. J Urol. 1991;146:1288-1290.
    • (1991) J Urol , vol.146 , pp. 1288-1290
    • Zoeller, G.1    Ringer, R.H.2
  • 18
    • 0027209468 scopus 로고
    • Testicular torsion in infants and children: Diagnosis with Doppler sonography
    • Patriquin HB, Yazbeck S, Trinh B, et al. Testicular torsion in infants and children: diagnosis with Doppler sonography. Radiology. 1993;188: 781-785.
    • (1993) Radiology , vol.188 , pp. 781-785
    • Patriquin, H.B.1    Yazbeck, S.2    Trinh, B.3
  • 19
    • 0029593605 scopus 로고
    • Evaluation of testicular volume by three orchidometers compared with ultrasonographic measurements
    • al Salim A, Murchison PJ, Rana A, et al. Evaluation of testicular volume by three orchidometers compared with ultrasonographic measurements. Br J Urol. 1995;76:632-635.
    • (1995) Br J Urol , vol.76 , pp. 632-635
    • Al Salim, A.1    Murchison, P.J.2    Rana, A.3
  • 20
    • 0036260525 scopus 로고    scopus 로고
    • A straightforward algorithm for the quantification of power Doppler signals
    • Jun WS, Lee KH, Koo K, et al. A straightforward algorithm for the quantification of power Doppler signals. Invest Radiol. 2002;37:343-348.
    • (2002) Invest Radiol , vol.37 , pp. 343-348
    • Jun, W.S.1    Lee, K.H.2    Koo, K.3
  • 21
    • 0031789328 scopus 로고    scopus 로고
    • Spiral twist of the spermatic cord: A reliable sign of testicular torsion
    • Baud C, Veyrac C, Couture A, et al. Spiral twist of the spermatic cord: a reliable sign of testicular torsion. Pediatr Radiol. 1998;28:950-954.
    • (1998) Pediatr Radiol , vol.28 , pp. 950-954
    • Baud, C.1    Veyrac, C.2    Couture, A.3
  • 22
    • 0029086191 scopus 로고
    • Shortcomings of color Doppler sonography in the diagnosis of testicular torsion
    • Terry DA, Jack SE. Shortcomings of color Doppler sonography in the diagnosis of testicular torsion. J Urol. 1995;154:1508-1510.
    • (1995) J Urol , vol.154 , pp. 1508-1510
    • Terry, D.A.1    Jack, S.E.2
  • 23
    • 0029787610 scopus 로고    scopus 로고
    • Ultrasound in the assessment of the acute scrotum
    • Herbener TE. Ultrasound in the assessment of the acute scrotum. J Clin Ultrasound. 1996;34:405-421.
    • (1996) J Clin Ultrasound , vol.34 , pp. 405-421
    • Herbener, T.E.1
  • 24
    • 0035152330 scopus 로고    scopus 로고
    • Testicular tissue bleeding as an indicator of gonadal salvageability in testicular torsion surgery
    • Arda IS, Ozyaylali I. Testicular tissue bleeding as an indicator of gonadal salvageability in testicular torsion surgery. BJU Int. 2001;87:89-92.
    • (2001) BJU Int , vol.87 , pp. 89-92
    • Arda, I.S.1    Ozyaylali, I.2
  • 25
    • 0020806642 scopus 로고
    • Experimental study of the sonographic diagnosis of testicular torsion
    • Hricak H, Lue T, Filly RA, et al. Experimental study of the sonographic diagnosis of testicular torsion. J Ultrasound Med. 1983;2:349-356.
    • (1983) J Ultrasound Med , vol.2 , pp. 349-356
    • Hricak, H.1    Lue, T.2    Filly, R.A.3
  • 26
    • 14244259795 scopus 로고    scopus 로고
    • Contrast-enhanced computed tomography and ultrasound for the evaluation of tumor blood flow
    • Broumas AR, Pollard RE, Bloch SH, et al. Contrast-enhanced computed tomography and ultrasound for the evaluation of tumor blood flow. Invest Radiol. 2005;40:134-147.
    • (2005) Invest Radiol , vol.40 , pp. 134-147
    • Broumas, A.R.1    Pollard, R.E.2    Bloch, S.H.3
  • 27
    • 1342323413 scopus 로고    scopus 로고
    • Detection of individual microbubbles of ultrasound contrast agents: Imaging of free-floating and targeted bubbles
    • Klibanov AL, Rasche PT, Hughes MS, et al. Detection of individual microbubbles of ultrasound contrast agents: imaging of free-floating and targeted bubbles. Invest Radiol. 2004;39:187-195.
    • (2004) Invest Radiol , vol.39 , pp. 187-195
    • Klibanov, A.L.1    Rasche, P.T.2    Hughes, M.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.