메뉴 건너뛰기




Volumn 2, Issue , 2005, Pages 518-521

The design of Rogowski coil with wide band using for partial discharge measurements

Author keywords

Partial discharge detection; Rogowski coil; XLPE cable

Indexed keywords

BANDWIDTH; CABLE SHEATHING; ELECTRIC CABLES; ELECTRIC DISTORTION; FREQUENCIES; MAGNETIC CORES; PARTIAL DISCHARGES;

EID: 25644433633     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/iseim.2005.193603     Document Type: Conference Paper
Times cited : (27)

References (7)
  • 1
    • 0032045622 scopus 로고    scopus 로고
    • On-line partial discharge detection in cables
    • N. H. Ahmed, N. N. Srinivas, "On-line Partial Discharge Detection in Cables", IEEE Trans. On DEI, Vol.5, No.2, pp.181-188, 1998.
    • (1998) IEEE Trans. on DEI , vol.5 , Issue.2 , pp. 181-188
    • Ahmed, N.H.1    Srinivas, N.N.2
  • 2
    • 0000182446 scopus 로고    scopus 로고
    • On-site partial discharge measurements on premoulded crossed-bonding joints of 170kV XLPE and EPR cables
    • Th. Heizmann, "On-site Partial Discharge Measurements on Premoulded Crossed-Bonding Joints of 170kV XLPE and EPR Cables", IEEE Trans. on PWRD, Vol.13, No.2, pp.330-335, 1998.
    • (1998) IEEE Trans. on PWRD , vol.13 , Issue.2 , pp. 330-335
    • Heizmann, Th.1
  • 3
    • 0032186852 scopus 로고    scopus 로고
    • UHF partial discharge monitoring and expert system diagnosis
    • T. Huecker, "UHF Partial Discharge Monitoring and Expert System Diagnosis", IEEE Trans. on PWRD, Vol.13, No.4, pp.1162-1167, 1998.
    • (1998) IEEE Trans. on PWRD , vol.13 , Issue.4 , pp. 1162-1167
    • Huecker, T.1
  • 4
    • 0026898384 scopus 로고
    • Development of a method of partial discharge detection in extra-high voltage cross-linked polyethylene insulated cable lines
    • Ginzo Katsuta, et al, "Development of a Method of Partial Discharge Detection in Extra-high Voltage Cross-linked Polyethylene Insulated Cable Lines", IEEE Trans. on PWRD, Vol.7, No.3, pp. 1068-1074, 1992.
    • (1992) IEEE Trans. on PWRD , vol.7 , Issue.3 , pp. 1068-1074
    • Katsuta, G.1
  • 5
    • 0033347270 scopus 로고    scopus 로고
    • Discrimination between internal PD and other pulses using directional coupling sensors on HV cable systems
    • D. Pommerenke et al, "Discrimination between Internal PD and Other Pulses Using Directional Coupling Sensors on HV Cable Systems", IEEE Trans. on DEI, Vol.6, No.6, pp.814-824, 1999.
    • (1999) IEEE Trans. on DEI , vol.6 , Issue.6 , pp. 814-824
    • Pommerenke, D.1
  • 6
    • 10044248532 scopus 로고    scopus 로고
    • Partial discharge measurement in XLPE cable joint by using VHF sensor
    • X. Li, et al, "Partial Discharge Measurement in XLPE Cable Joint by Using VHF Sensor", IEEE Conf. on SD, Vol.2, pp.669-671, 2004.
    • (2004) IEEE Conf. on SD , vol.2 , pp. 669-671
    • Li, X.1
  • 7
    • 0032045622 scopus 로고    scopus 로고
    • On-line partial discharge detection in cables
    • N. H. Ahmed, N. N, "Srinivas. On-line Partial Discharge Detection in Cables", IEEE Trans. on DEI, Vol.5, No.2, pp.181-188, 1998.
    • (1998) IEEE Trans. on DEI , vol.5 , Issue.2 , pp. 181-188
    • Ahmed, N.H.1    Srinivas, N.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.