Volumn 6, Issue 3, 2004, Pages 308-311

Array reactors for parallel synthesis

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ATMOSPHERE; CHEMICAL REACTION; COMBINATORIAL CHEMISTRY; HEATING; HIGH THROUGHPUT SCREENING; HYDROGENATION; SYNTHESIS;

EID: 2542630532     PISSN: 15204766     EISSN: None     Source Type: Journal    
DOI: 10.1021/cc0499643     Document Type: Article
Times cited : (4)

References (13)
  • 6
    • 2542546937 scopus 로고    scopus 로고
    • http://www.combinatorial.com/instruments.html
    • Listings of most commercially available equipment for combinatorial chemistry can be found on the web at sites such as http://www.combichemlab.com/ website/files/home.htm and http://www.combinatorial.com/instruments.html.
  • 7
    • 2542559296 scopus 로고    scopus 로고
    • Detailed descriptions of the microtiter footprint, as defined by the Society for Biological Screening, can be found at http://sbsonline.com/msdc/ index.html.
  • 8
    • 2542618733 scopus 로고    scopus 로고
    • note
    • Equipment parts are sometimes shown as partially transparent to help visualize how they work.
  • 9
    • 2542620210 scopus 로고    scopus 로고
    • Vessel Handling System Useful for Combinatorial Chemistry. U.S. Patent 5,785,927; 1998
    • Scott, W. L.; Schonegg, R. A.; Cwi, C. L. Vessel Handling System Useful for Combinatorial Chemistry. U.S. Patent 5,785,927; 1998.
    • Scott, W.L.1    Schonegg, R.A.2    Cwi, C.L.3
  • 10
    • 2542515004 scopus 로고    scopus 로고
    • IKA WORKS, Inc., 2635 Northchase Pkwy, SE, Wilmington, NC, 28405
    • Model: IKAMAG RCT basic, IKA WORKS, Inc., 2635 Northchase Pkwy, SE, Wilmington, NC, 28405. Web site: http://www.ika.net/.
    • Model: IKAMAG RCT Basic
  • 11
    • 2542598820 scopus 로고    scopus 로고
    • http://www.jkem.com/
    • Stirring systems for 96-well plates are available from V&P Scientific, Inc., 9823 Pacific Heights Blvd., Suite T, San Diego, CA 92121. Web site: http://www.vp-scientific.com/. Orbital shakers with heating are available from J-KEM Scientific, Inc. 6970 Olive Blvd., St. Louis, MO 63130. Web site: http://www.jkem.com/.
  • 12
    • 2542626275 scopus 로고    scopus 로고
    • note
    • Evolution of the reactor design is aimed primarily at reducing manufacturing costs and increasing ease of use and reusability. For example, the machined lip described for the SynthArray-96 will not bear repeated use as well as the O-rings. However, an O-ring design would require custom O-rings at a considerable cost. A very similar and functional previous design, which required pouring silicone around the tubes to make a seal, was never embraced by chemists in our labs.
  • 13
    • 2542592783 scopus 로고    scopus 로고
    • note
    • Part No. 14-957-76A, Fisher Scientific International, Inc., Liberty Lane, Hampton, NH 03842.