-
1
-
-
0029919861
-
Bone mass in Parkinson's disease: A study with three methods
-
Revilla M, de la Sierra G, Aguado F, Varela L, Jimenez-Jimenez F, Rico H (1996) Bone mass in Parkinson's disease: a study with three methods. Calcif Tissue Int 58:311-315
-
(1996)
Calcif Tissue Int
, vol.58
, pp. 311-315
-
-
Revilla, M.1
De La Sierra, G.2
Aguado, F.3
Varela, L.4
Jimenez-Jimenez, F.5
Rico, H.6
-
2
-
-
0029765483
-
Ultrasound parameters in osteoporotic patients treated with salmon calcitonin: A longitudinal study
-
Gonnelli S, Cepollaro C, Pondrelli C, Martini S, Rossi S, Gennari C (1996) Ultrasound parameters in osteoporotic patients treated with salmon calcitonin: a longitudinal study. Osteoporosis Int 6:303-307
-
(1996)
Osteoporosis Int
, vol.6
, pp. 303-307
-
-
Gonnelli, S.1
Cepollaro, C.2
Pondrelli, C.3
Martini, S.4
Rossi, S.5
Gennari, C.6
-
3
-
-
0025032044
-
Prediction of hip fracture in elderly women: A prospective study
-
Porter R, Miller C, Grainger D, Palmer S (1990) Prediction of hip fracture in elderly women: a prospective study. BMJ 301: 638-641
-
(1990)
BMJ
, vol.301
, pp. 638-641
-
-
Porter, R.1
Miller, C.2
Grainger, D.3
Palmer, S.4
-
4
-
-
0027326918
-
Preliminary evaluation of a new ultrasound bone densitometer
-
Lees B, Stevenson J (1993) Preliminary evaluation of a new ultrasound bone densitometer. Calcif Tissue Int 53:149-152
-
(1993)
Calcif Tissue Int
, vol.53
, pp. 149-152
-
-
Lees, B.1
Stevenson, J.2
-
5
-
-
0025470090
-
A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone
-
Langton C, Ali A, Riggs C, Evans G, Bonfield W (1990) A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone. Clin Phys Physiol Meas 11(3):243-249
-
(1990)
Clin Phys Physiol Meas
, vol.11
, Issue.3
, pp. 243-249
-
-
Langton, C.1
Ali, A.2
Riggs, C.3
Evans, G.4
Bonfield, W.5
-
6
-
-
0342685631
-
Reproducibility of unconnected velocity of sound does not indicate true precision
-
Brandenburger G, Waud K, Baran D (1992) Reproducibility of unconnected velocity of sound does not indicate true precision. J Bone Miner Res (suppl)1:S184
-
(1992)
J Bone Miner Res (Suppl)
, vol.1
-
-
Brandenburger, G.1
Waud, K.2
Baran, D.3
-
7
-
-
0025162019
-
Assessment of broadband ultrasound attenuation in the os calcis in vitro
-
McCloskey E, Murray S, Charlesworth D, Miller C, Fordham J, Clifford K, Atkins R, Kanis J (1990) Assessment of broadband ultrasound attenuation in the os calcis in vitro. Clin Sci 78:221-227
-
(1990)
Clin Sci
, vol.78
, pp. 221-227
-
-
McCloskey, E.1
Murray, S.2
Charlesworth, D.3
Miller, C.4
Fordham, J.5
Clifford, K.6
Atkins, R.7
Kanis, J.8
-
8
-
-
0027982881
-
Influence of fat on ultrasound measurements of the os calcis
-
Kotzki P, Buyck D, Hans D, Thomas E, Bonnel F, Favier F, Meunier P, Rossi M (1994) Influence of fat on ultrasound measurements of the os calcis. Calcif Tissue Int 54:91-95
-
(1994)
Calcif Tissue Int
, vol.54
, pp. 91-95
-
-
Kotzki, P.1
Buyck, D.2
Hans, D.3
Thomas, E.4
Bonnel, F.5
Favier, F.6
Meunier, P.7
Rossi, M.8
-
9
-
-
0029094163
-
The impact of bone size on broadband ultrasound attenuation
-
Wu C, Gluer C, Jergas M, Bendavid E, Genant H (1995) The impact of bone size on broadband ultrasound attenuation. Bone 16(1):137-141
-
(1995)
Bone
, vol.16
, Issue.1
, pp. 137-141
-
-
Wu, C.1
Gluer, C.2
Jergas, M.3
Bendavid, E.4
Genant, H.5
-
10
-
-
0030052159
-
Broadband ultrasound attenuation value dependence on bone width in vitro
-
Serpe L, Rho J (1996) Broadband ultrasound attenuation value dependence on bone width in vitro. Phys Med Biol 41:197-202
-
(1996)
Phys Med Biol
, vol.41
, pp. 197-202
-
-
Serpe, L.1
Rho, J.2
-
11
-
-
0027198066
-
Measurements of postmenopausal bone loss with a new contact ultrasound system
-
Herd R, Blake G, Ramalingam T, Miller C, Ryan P, Fogelman I (1993) Measurements of postmenopausal bone loss with a new contact ultrasound system. Calcif Tissue Int 53:153-157
-
(1993)
Calcif Tissue Int
, vol.53
, pp. 153-157
-
-
Herd, R.1
Blake, G.2
Ramalingam, T.3
Miller, C.4
Ryan, P.5
Fogelman, I.6
-
13
-
-
0021408517
-
The measurement of broadband ultrasonic attenuation in cancellous bone
-
Langton C, Palmer S, Porter R (1984) The measurement of broadband ultrasonic attenuation in cancellous bone. Eng Med 13:89-91
-
(1984)
Eng Med
, vol.13
, pp. 89-91
-
-
Langton, C.1
Palmer, S.2
Porter, R.3
-
14
-
-
0028575873
-
Should broadband ultrasonic attenuation be normalized for the width of the calcaneus?
-
Blake G, Herd R, Miller C, Fogelman I (1994) Should broadband ultrasonic attenuation be normalized for the width of the calcaneus? Br J Radiol 67:1206-1209
-
(1994)
Br J Radiol
, vol.67
, pp. 1206-1209
-
-
Blake, G.1
Herd, R.2
Miller, C.3
Fogelman, I.4
-
15
-
-
0026676315
-
The effect of bone structure on ultrasonic attenuation and velocity
-
Tavakoli M, Evans J (1992) The effect of bone structure on ultrasonic attenuation and velocity. Ultrasonics 30(6):389-395
-
(1992)
Ultrasonics
, vol.30
, Issue.6
, pp. 389-395
-
-
Tavakoli, M.1
Evans, J.2
|