메뉴 건너뛰기




Volumn 101, Issue 1-3, 2004, Pages 187-194

Direct monitoring of biochemical processes using micro-structured heat power detectors

Author keywords

Calorimetry; Degree of mixing; Enzymes; Flow through chip calorimeter; Micro kelvin thermostat

Indexed keywords

CALORIMETRY; CONTROL SYSTEMS; MICROPROCESSOR CHIPS; MICROSTRUCTURE; MIXTURES; THERMOSTATS;

EID: 2542477216     PISSN: 13858947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cej.2003.11.006     Document Type: Article
Times cited : (12)

References (17)
  • 1
    • 0022813826 scopus 로고
    • Thermal sensors based on the Seebeck effect
    • Van Herwaarden A.W.Sarro P.M.Thermal sensors based on the Seebeck effect Sens. Actuators 10 1986 321-346
    • (1986) Sens. Actuators , vol.10 , pp. 321-346
    • Van Herwaarden, A.W.1    Sarro, P.M.2
  • 2
    • 0038880970 scopus 로고    scopus 로고
    • Chip reactor for microfluid calorimetry
    • Koehler J.M.Zieren M.Chip reactor for microfluid calorimetry Thermochim. Acta 3101-2 1998 25-35
    • (1998) Thermochim. Acta , vol.310 , Issue.1-2 , pp. 25-35
    • Koehler, J.M.1    Zieren, M.2
  • 3
    • 0032595496 scopus 로고    scopus 로고
    • Recent developments in integrated circuit calorimetry
    • Lerchner J.Wolf A.Wolf G.Recent developments in integrated circuit calorimetry J. Therm. Anal. Calorim. 571 1999 241-251
    • (1999) J. Therm. Anal. Calorim. , vol.57 , Issue.1 , pp. 241-251
    • Lerchner, J.1    Wolf, A.2    Wolf, G.3
  • 5
    • 0037203913 scopus 로고    scopus 로고
    • Sequential flow injection analysis of complex systems using calorimetric detection
    • Wolf A.Weber A.Huettl R.Lerchner J.Wolf G.Sequential flow injection analysis of complex systems using calorimetric detection Thermochim. Acta 3821-2 2002 89-98
    • (2002) Thermochim. Acta , vol.382 , Issue.1-2 , pp. 89-98
    • Wolf, A.1    Weber, A.2    Huettl, R.3    Lerchner, J.4    Wolf, G.5
  • 6
    • 84892183006 scopus 로고    scopus 로고
    • Delft, NL.
    • Xensor Integration, Delft, NL. http://www.xensor.nl
    • Xensor Integration
  • 7
    • 2342638278 scopus 로고    scopus 로고
    • Determination of molar heats of absorption of enantiomers into thin chiral coatings by combined IC calorimetric and microgravimetric (QMB) measurements. I. IC calorimetric measurements of heats of absorption
    • in press
    • J. Lerchner, R. Kirchner, J. Seidel, D. Waehlisch, G. Wolf, Determination of molar heats of absorption of enantiomers into thin chiral coatings by combined IC calorimetric and microgravimetric (QMB) measurements. I. IC calorimetric measurements of heats of absorption, Thermochim. Acta, in press.
    • Thermochim. Acta
    • Lerchner, J.1    Kirchner, R.2    Seidel, J.3    Waehlisch, D.4    Wolf, G.5
  • 8
    • 0002598261 scopus 로고    scopus 로고
    • A high resolution IC-calorimeter for the determination of heats of absorption onto thin coatings
    • D. Caspary, M. Schroepfer, J. Lerchner, G. Wolf, A high resolution IC-calorimeter for the determination of heats of absorption onto thin coatings, Thermochim. Acta 337 (1-2) (1999).
    • (1999) Thermochim. Acta , vol.337 , Issue.1-2
    • Caspary, D.1    Schroepfer, M.2    Lerchner, J.3    Wolf, G.4
  • 10
    • 0000115977 scopus 로고
    • High-speed scanning microcalorimetry with monolayer sensitivity
    • Lai S.L.Ramanath G.Allen L.H.Infante P.Ma Z.High-speed scanning microcalorimetry with monolayer sensitivity Appl. Phys. Lett. 679 1995 1229-1231
    • (1995) Appl. Phys. Lett. , vol.67 , Issue.9 , pp. 1229-1231
    • Lai, S.L.1    Ramanath, G.2    Allen, L.H.3    Infante, P.4    Ma, Z.5
  • 12
    • 0000724255 scopus 로고    scopus 로고
    • Ambient perturbation reduction in micro-sized calorimetric systems
    • Lerchner J.Wolf G.Torralba A.Torra V.Ambient perturbation reduction in micro-sized calorimetric systems Thermochim. Acta 30212 1997 201-210
    • (1997) Thermochim. Acta , vol.302 , Issue.12 , pp. 201-210
    • Lerchner, J.1    Wolf, G.2    Torralba, A.3    Torra, V.4
  • 14
    • 0033103693 scopus 로고    scopus 로고
    • Characterization of mixing in micromixers by a test reaction: Single mixing units and mixer arrays
    • Ehrfeld W.Golbig K.Hessel V.Loewe H.Richter T.Characterization of mixing in micromixers by a test reaction: single mixing units and mixer arrays Ind. Eng. Chem. Res. 38 1999 1075-1082
    • (1999) Ind. Eng. Chem. Res. , vol.38 , pp. 1075-1082
    • Ehrfeld, W.1    Golbig, K.2    Hessel, V.3    Loewe, H.4    Richter, T.5
  • 15
    • 0033626159 scopus 로고    scopus 로고
    • Characterization of micromixing efficiency by the iodide-iodate reaction system. Part I. Experimental procedure
    • Guichardon P.Falk L.Characterization of micromixing efficiency by the iodide-iodate reaction system. Part I. Experimental procedure Chem. Eng. Sci. 55 2000 4233-4243
    • (2000) Chem. Eng. Sci. , vol.55 , pp. 4233-4243
    • Guichardon, P.1    Falk, L.2
  • 16
    • 0029364241 scopus 로고
    • A coaxial jet mixer for rapid kinetic analysis in flow injection and flow injection cytometry
    • Scampavia L.D.Blankenstein G.Ruzicka J.Christian G.D.A coaxial jet mixer for rapid kinetic analysis in flow injection and flow injection cytometry Anal. Chem. 67 1995 2743-2749
    • (1995) Anal. Chem. , vol.67 , pp. 2743-2749
    • Scampavia, L.D.1    Blankenstein, G.2    Ruzicka, J.3    Christian, G.D.4
  • 17
    • 0037203936 scopus 로고    scopus 로고
    • Accuracy in integrated circuit (IC) calorimeters
    • Lerchner J.Wolf G.Auguet C.Torra V.Accuracy in integrated circuit (IC) calorimeters Thermochim. Acta 3821-2 2002 65-76
    • (2002) Thermochim. Acta , vol.382 , Issue.1-2 , pp. 65-76
    • Lerchner, J.1    Wolf, G.2    Auguet, C.3    Torra, V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.