메뉴 건너뛰기




Volumn 28, Issue 4, 2005, Pages 563-568

Fibrinolytic inhibitors in off-pump coronary surgery: A prospective, randomized, double-blind TAP study (tranexamic acid, aprotinin, placebo)

Author keywords

Aprotinin; Hemostasis; Off pump coronary artery bypass; Tranexamic acid

Indexed keywords

ANTIFIBRINOLYTIC AGENT; APROTININ; HEMOGLOBIN; TRANEXAMIC ACID;

EID: 25144525008     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2005.06.027     Document Type: Article
Times cited : (49)

References (25)
  • 1
    • 0030426190 scopus 로고    scopus 로고
    • A review of post-cardiopulmonary bypass bleeding, aminocaproic acid, tranexamic acid, and aprotinin
    • R.W. Barrons, and J.S. Jahr A review of post-cardiopulmonary bypass bleeding, aminocaproic acid, tranexamic acid, and aprotinin Am J Ther 3 1996 821 838
    • (1996) Am J Ther , vol.3 , pp. 821-838
    • Barrons, R.W.1    Jahr, J.S.2
  • 2
    • 0031415922 scopus 로고    scopus 로고
    • Drugs to minimize perioperative blood loss in cardiac surgery: Meta-analyses using peri-operative blood transfusion as the outcome. the international study of perioperative transfusion (ISPOT) investigators
    • A. Laupacis, and D. Fergusson Drugs to minimize perioperative blood loss in cardiac surgery: meta-analyses using peri-operative blood transfusion as the outcome. The international study of perioperative transfusion (ISPOT) investigators Anaesth Analg 85 1997 1258 1267
    • (1997) Anaesth Analg , vol.85 , pp. 1258-1267
    • Laupacis, A.1    Fergusson, D.2
  • 4
    • 3543089755 scopus 로고    scopus 로고
    • Prophylactic tranexamic acid in elective, primary coronary bypass surgery using cardiopulmonary bypass
    • J.J. Andreasen, and C. Nielsen Prophylactic tranexamic acid in elective, primary coronary bypass surgery using cardiopulmonary bypass Eur J Cardiothorac Surg 26 2004 311 317
    • (2004) Eur J Cardiothorac Surg , vol.26 , pp. 311-317
    • Andreasen, J.J.1    Nielsen, C.2
  • 5
    • 0035171792 scopus 로고    scopus 로고
    • Pharmacologic preservation of the hemostatic system during cardiac surgery
    • J.H. Levy Pharmacologic preservation of the hemostatic system during cardiac surgery Ann Thorac Surg 72 2001 S1814 S1820
    • (2001) Ann Thorac Surg , vol.72
    • Levy, J.H.1
  • 6
    • 0035163406 scopus 로고    scopus 로고
    • Mechanisms and attenuation of hemostatic activation during extracorporeal circulation
    • G.J. Despotis, M.S. Avidan, and C.W. Hogue Jr Mechanisms and attenuation of hemostatic activation during extracorporeal circulation Ann Thorac Surg 72 2001 S1824 S1831
    • (2001) Ann Thorac Surg , vol.72
    • Despotis, G.J.1    Avidan, M.S.2    Hogue Jr., C.W.3
  • 7
    • 0034908049 scopus 로고    scopus 로고
    • Tranexamic acid in off-pump coronary surgery: A preliminary, randomized, double-blind, placebo-controlled study
    • V. Casati, Ch. Gerly, A. Franco, G. Torri, A. D'Angelo, S. Benussi, and O. Alfieri Tranexamic acid in off-pump coronary surgery: a preliminary, randomized, double-blind, placebo-controlled study Ann Thorac Surg 72 2001 470 475
    • (2001) Ann Thorac Surg , vol.72 , pp. 470-475
    • Casati, V.1    Gerly, Ch.2    Franco, A.3    Torri, G.4    D'Angelo, A.5    Benussi, S.6    Alfieri, O.7
  • 9
    • 0038264388 scopus 로고    scopus 로고
    • Tranexamic acid reduces bleeding after off-pump coronary artery bypass grafting
    • M. Jares, T. Vanek, Z. Straka, and P. Brucek Tranexamic acid reduces bleeding after off-pump coronary artery bypass grafting J Cardiovasc Surg (Torino) 44 2003 205 208
    • (2003) J Cardiovasc Surg (Torino) , vol.44 , pp. 205-208
    • Jares, M.1    Vanek, T.2    Straka, Z.3    Brucek, P.4
  • 10
    • 3042811398 scopus 로고    scopus 로고
    • Effects of tranexamic acid in postoperative bleeding and related hematological variables in coronary surgery: Comparison between on-pump and off-pump techniques
    • V. Casati, P. Della Valle, S. Benussi, A. Franco, C. Gerli, P. Baili, O. Alfieri, and A. D'Angelo Effects of tranexamic acid in postoperative bleeding and related hematological variables in coronary surgery: comparison between on-pump and off-pump techniques J Thorac Cardiovasc Surg 128 2004 83 91
    • (2004) J Thorac Cardiovasc Surg , vol.128 , pp. 83-91
    • Casati, V.1    Della Valle, P.2    Benussi, S.3    Franco, A.4    Gerli, C.5    Baili, P.6    Alfieri, O.7    D'Angelo, A.8
  • 11
    • 0032709832 scopus 로고    scopus 로고
    • Blood product use in cardiac revascularization: Comparison of on- and off-pump techniques
    • N.D. Nader, W.Z. Zhadra, N.T. Reich, D.R. Bacon, T.A. Salerno, and A.L. Panos Blood product use in cardiac revascularization: comparison of on- and off-pump techniques Ann Thorac Surg 68 1999 1640 1643
    • (1999) Ann Thorac Surg , vol.68 , pp. 1640-1643
    • Nader, N.D.1    Zhadra, W.Z.2    Reich, N.T.3    Bacon, D.R.4    Salerno, T.A.5    Panos, A.L.6
  • 13
    • 14644419526 scopus 로고    scopus 로고
    • Risk factors for hemorrhage-related reexploration and blood transfusion after conventional versus coronary revascularization without cardiopulmonary bypass
    • T.L. Frankel, S.C. Stamou, R.C. Lowery, E.I. Kapetanakis, P.C. Hill, E. Haile, and P.J. Corso Risk factors for hemorrhage-related reexploration and blood transfusion after conventional versus coronary revascularization without cardiopulmonary bypass Eur J Cardiothorac Surg 27 2005 494 500
    • (2005) Eur J Cardiothorac Surg , vol.27 , pp. 494-500
    • Frankel, T.L.1    Stamou, S.C.2    Lowery, R.C.3    Kapetanakis, E.I.4    Hill, P.C.5    Haile, E.6    Corso, P.J.7
  • 15
    • 0036839789 scopus 로고    scopus 로고
    • Routine immediate extubation for off-pump coronary artery bypass grafting without thoracic epidural analgesia
    • Z. Straka, P. Brucek, T. Vanek, J. Votava, and P. Widimsky Routine immediate extubation for off-pump coronary artery bypass grafting without thoracic epidural analgesia Ann Thorac Surg 74 2002 1544 1547
    • (2002) Ann Thorac Surg , vol.74 , pp. 1544-1547
    • Straka, Z.1    Brucek, P.2    Vanek, T.3    Votava, J.4    Widimsky, P.5
  • 16
    • 0346656703 scopus 로고    scopus 로고
    • Less invasive cardiac anesthesia: An ultra-fast-track procedure avoiding thoracic epidural analgesia
    • P.J. Brucek, Z. Straka, T. Vanek, and M. Jares Less invasive cardiac anesthesia: an ultra-fast-track procedure avoiding thoracic epidural analgesia Heart Surg Forum 6 2003 E107 E110
    • (2003) Heart Surg Forum , vol.6
    • Brucek, P.J.1    Straka, Z.2    Vanek, T.3    Jares, M.4
  • 17
    • 0033524140 scopus 로고    scopus 로고
    • Pharmacological strategies to decrease excessive blood loss in cardiac surgery: A meta-analysis of clinically relevant endpoints
    • M. Levi, M.E. Cromheecke, E. de Jonge, M.H. Prins, B.J.M. de Mol, E. Briët, and H.R. Büller Pharmacological strategies to decrease excessive blood loss in cardiac surgery: a meta-analysis of clinically relevant endpoints Lancet 354 1999 1940 1947
    • (1999) Lancet , vol.354 , pp. 1940-1947
    • Levi, M.1    Cromheecke, M.E.2    De Jonge, E.3    Prins, M.H.4    De Mol, B.J.M.5    Briët, E.6    Büller, H.R.7
  • 19
    • 0346724637 scopus 로고    scopus 로고
    • Impact of tranexamic acid vs. aprotinin on blood loss and transfusion requirements after cardiopulmonary bypass: A prospective, randomised, double-blind trial
    • K. Hekmat, T. Zimmermann, S. Kampe, S.M. Kasper, H.J. Weber, H.J. Geissler, and U. Mehlhorn Impact of tranexamic acid vs. aprotinin on blood loss and transfusion requirements after cardiopulmonary bypass: a prospective, randomised, double-blind trial Curr Med Res Opin 20 2004 121 126
    • (2004) Curr Med Res Opin , vol.20 , pp. 121-126
    • Hekmat, K.1    Zimmermann, T.2    Kampe, S.3    Kasper, S.M.4    Weber, H.J.5    Geissler, H.J.6    Mehlhorn, U.7
  • 20
    • 0029729898 scopus 로고    scopus 로고
    • Aprotinin: Safe and effective only with the full-dose regimen
    • P.K. Smith, and L.H. Muhlbaier Aprotinin: safe and effective only with the full-dose regimen Ann Thorac Surg 62 1996 1575 1577
    • (1996) Ann Thorac Surg , vol.62 , pp. 1575-1577
    • Smith, P.K.1    Muhlbaier, L.H.2
  • 24
    • 3142754386 scopus 로고    scopus 로고
    • Efficacy and safety of aprotinin in cardiac surgery
    • J.H. Levy Efficacy and safety of aprotinin in cardiac surgery Orthopedics 27 2004 S659 S662
    • (2004) Orthopedics , vol.27
    • Levy, J.H.1
  • 25
    • 0033038250 scopus 로고    scopus 로고
    • Procoagulant activity after off-pump coronary operation: Is the current anticoagulation adequate?
    • M. Mariani, Y. Gu, P. Boonstra, J.G. Grandjean, W. van Oeveren, and T. Ebels Procoagulant activity after off-pump coronary operation: is the current anticoagulation adequate? Ann Thorac Surg 67 1999 1370 1375
    • (1999) Ann Thorac Surg , vol.67 , pp. 1370-1375
    • Mariani, M.1    Gu, Y.2    Boonstra, P.3    Grandjean, J.G.4    Van Oeveren, W.5    Ebels, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.