메뉴 건너뛰기




Volumn 16, Issue 3, 2005, Pages 308-312

Oxidized titanium implants (Nobel Biocare® TiUnite™) compared with turned titanium implants (Nobel Biocare® mark III™) with respect to implant failure in a group of consecutive patients treated with early functional loading and two-stage protocol

Author keywords

Dental implants; Implant survival; Oxidized surface; Surface characterization; Turned surface

Indexed keywords

BIOMATERIAL; TITANIUM;

EID: 25144513055     PISSN: 09057161     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2005.01101.x     Document Type: Article
Times cited : (63)

References (21)
  • 4
  • 6
    • 0034263976 scopus 로고    scopus 로고
    • Removal torque and histomorphometric investigation of 4 different titanium surfaces: An experimental study in the rabbit tibia
    • Cordioli, G., Majzoub, Z., Piattelli, A. & Scarano, A.T.I. (2000) Removal torque and histomorphometric investigation of 4 different titanium surfaces: an experimental study in the rabbit tibia. International Journal of Oral & Maxillofacial Implants 15: 668-674.
    • (2000) International Journal of Oral & Maxillofacial Implants , vol.15 , pp. 668-674
    • Cordioli, G.1    Majzoub, Z.2    Piattelli, A.3    Scarano, A.T.I.4
  • 7
    • 0034139628 scopus 로고    scopus 로고
    • Immediate functional loading of Branemark single tooth implants. An 18 months clinical pilot follow-up study
    • Ericsson, I., Nilson, H., Lindh, T., Nilner, K. & Randow, K. (2000a) Immediate functional loading of Branemark single tooth implants. An 18 months clinical pilot follow-up study. Clinical Oral Implants Research 11: 26-33.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 26-33
    • Ericsson, I.1    Nilson, H.2    Lindh, T.3    Nilner, K.4    Randow, K.5
  • 8
    • 0031243162 scopus 로고    scopus 로고
    • Some clinical and radiographical features of submerged and non-submerged titanium implants. A 5-year follow-up study
    • Ericsson, I., Randow, K., Nilner, K. & Petersson, A. (1997) Some clinical and radiographical features of submerged and non-submerged titanium implants. A 5-year follow-up study. Clinical Oral Implants Research 8: 422-426.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 422-426
    • Ericsson, I.1    Randow, K.2    Nilner, K.3    Petersson, A.4
  • 10
    • 0034575060 scopus 로고    scopus 로고
    • Anchorage of titanium implants with different surface characteristics: An experimental study in rabbits
    • Gotfredsen, K., Berglundh, T. & Lindhe, J. (2000) Anchorage of titanium implants with different surface characteristics: an experimental study in rabbits. Clinical Implant Dentistry & Related Research 2: 120-128.
    • (2000) Clinical Implant Dentistry & Related Research , vol.2 , pp. 120-128
    • Gotfredsen, K.1    Berglundh, T.2    Lindhe, J.3
  • 11
    • 0035288480 scopus 로고    scopus 로고
    • A prospective 5-year study of fixed partial prostheses supported by implants with machined and TiO2-blasted surface
    • Gotfredsen, K. & Karlsson, U. (2001) A prospective 5-year study of fixed partial prostheses supported by implants with machined and TiO2-blasted surface. Journal of Prosthodontics 10: 2-7.
    • (2001) Journal of Prosthodontics , vol.10 , pp. 2-7
    • Gotfredsen, K.1    Karlsson, U.2
  • 13
    • 0035320462 scopus 로고    scopus 로고
    • Histologic evaluation of the bone integration of TiO(2) blasted and turned titanium microimplants in humans
    • Ivanoff, C.J., Hallgren, C., Widmark, G., Sennerby, L. & Wennerberg, A. (2001) Histologic evaluation of the bone integration of TiO(2) blasted and turned titanium microimplants in humans. Clinical Oral Implants Research 12: 128-134.
    • (2001) Clinical Oral Implants Research , vol.12 , pp. 128-134
    • Ivanoff, C.J.1    Hallgren, C.2    Widmark, G.3    Sennerby, L.4    Wennerberg, A.5
  • 15
    • 0032135121 scopus 로고    scopus 로고
    • A 2-year report on maxillary and mandibular fixed partial dentures supported by Astra Tech dental implants. A comparison of 2 implants
    • Karlsson, U., Gotfredsen, K. & Olsson, C. (1998) A 2-year report on maxillary and mandibular fixed partial dentures supported by Astra Tech dental implants. A comparison of 2 implants. Clinical Oral Implants Research 9: 235-242.
    • (1998) Clinical Oral Implants Research , vol.9 , pp. 235-242
    • Karlsson, U.1    Gotfredsen, K.2    Olsson, C.3
  • 17
  • 19
    • 0038016683 scopus 로고    scopus 로고
    • The significance of the surface properties of oxidized titanium to the bone response: Special emphasis on potential biochemical bonding of titanium implants
    • Sul, Y.T. (2003) The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of titanium implants. Biomaterials 24: 3893-3907.
    • (2003) Biomaterials , vol.24 , pp. 3893-3907
    • Sul, Y.T.1
  • 20
  • 21
    • 0031255466 scopus 로고    scopus 로고
    • Preliminary results of a multicenter study evaluating a chemically enhanced surface for machined commercially pure titanium implants
    • Sullivan, D.Y., Sherwood, R.L. & Mai, T.N. (1997) Preliminary results of a multicenter study evaluating a chemically enhanced surface for machined commercially pure titanium implants. Journal of Prosthetic Dentistry 78: 379-386.
    • (1997) Journal of Prosthetic Dentistry , vol.78 , pp. 379-386
    • Sullivan, D.Y.1    Sherwood, R.L.2    Mai, T.N.3