메뉴 건너뛰기




Volumn 5765, Issue PART 2, 2005, Pages 811-819

Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers

Author keywords

Accelerometer; Active noise cancellation; Motion artifact reduction; PPG; System ID; Wearable sensors

Indexed keywords

ACTIVE NOISE CANCELLATION; MOTION ARTIFACT REDUCTION; PPG; SYSTEM ID; WEARABLE SENSORS;

EID: 25144471566     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.600781     Document Type: Conference Paper
Times cited : (38)

References (8)
  • 3
    • 0033060589 scopus 로고    scopus 로고
    • Physical activity monitoring based on acceletrometry: Validation and comparison with video observation
    • Aminian K, Robert P, Buchser EE, Rutschmann B, Hayoz D, Depairon M, "Physical activity monitoring based on acceletrometry: Validation and comparison with video observation", Med Biol Eng Comput, 37(3): 304-308, 1999.
    • (1999) Med Biol Eng Comput , vol.37 , Issue.3 , pp. 304-308
    • Aminian, K.1    Robert, P.2    Buchser, E.E.3    Rutschmann, B.4    Hayoz, D.5    Depairon, M.6
  • 4
    • 0031879120 scopus 로고    scopus 로고
    • Quantification of physical activities by means of ambulatory accelerometry: A validation study
    • Bussmann, J.B., J.H. Tulen, E.C. van Herel, and H.J. Stam, Quantification of physical activities by means of ambulatory accelerometry: a validation study. Psychophysiology, 35(5): p. 488-96, 1998.
    • (1998) Psychophysiology , vol.35 , Issue.5 , pp. 488-496
    • Bussmann, J.B.1    Tulen, J.H.2    Van Herel, E.C.3    Stam, H.J.4
  • 5
    • 0034968268 scopus 로고    scopus 로고
    • Artifact-resistant, power-efficient design of finger-ring plethysmographic sensors
    • July
    • Rhee, S-W., Yang, B-H, and Asada, H., "Artifact-Resistant, Power-Efficient Design of Finger-Ring Plethysmographic Sensors", IEEE Transactions on Biomedical Engineering, Vol.48, No.7, pp.795-805, July 2001.
    • (2001) IEEE Transactions on Biomedical Engineering , vol.48 , Issue.7 , pp. 795-805
    • Rhee, S.-W.1    Yang, B.-H.2    Asada, H.3
  • 6
    • 0016643045 scopus 로고
    • Adaptive noise canceling: Principles and applications
    • Dec.
    • Bernard Widrow, Robert C. Goodlin et al., "Adaptive Noise Canceling: Principles and Applications", Proceedings of the IEEE, vol. 63, pp. 1692-1716, Dec.1975.
    • (1975) Proceedings of the IEEE , vol.63 , pp. 1692-1716
    • Widrow, B.1    Goodlin, R.C.2
  • 7
    • 11144331000 scopus 로고    scopus 로고
    • Active noise cancellation using MEMS accelerometers for motion-tolerant wearable biosensors
    • Jiang, Hong-Hui, Asada, H. Harry, and Gibbs, Peter, "Active Noise Cancellation Using MEMS Accelerometers for Motion-Tolerant Wearable Biosensors", Proceedings of 2004 IEEE EMBS Conference, 2004.
    • (2004) Proceedings of 2004 IEEE EMBS Conference
    • Jiang, H.-H.1    Asada, H.H.2    Gibbs, P.3
  • 8
    • 2742525547 scopus 로고    scopus 로고
    • Cardiac, respiratory, and locomotor coordination during walking in humans
    • Niizeki K, Kawahara K, Miyamoto Y, "Cardiac, respiratory, and locomotor coordination during walking in humans", Folia Primatol (Basel). 1996;66(1-4):226-39.
    • (1996) Folia Primatol (Basel) , vol.66 , Issue.1-4 , pp. 226-239
    • Niizeki, K.1    Kawahara, K.2    Miyamoto, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.