메뉴 건너뛰기




Volumn 21, Issue 14, 2005, Pages 3066-3073

Algorithms for alignment of mass spectrometry proteomic data

Author keywords

[No Author keywords available]

Indexed keywords

PEPTIDE; PROTEOME;

EID: 25144448206     PISSN: 13674803     EISSN: 13674811     Source Type: Journal    
DOI: 10.1093/bioinformatics/bti482     Document Type: Article
Times cited : (76)

References (14)
  • 1
    • 0036645099 scopus 로고    scopus 로고
    • Serum protein fingerprinting coupled with a pattern-matching algorithm distinguishes prostate cancer from benign prostate hyperplasia healthy men
    • Adam,B.-L. et al. (2002) Serum protein fingerprinting coupled with a pattern-matching algorithm distinguishes prostate cancer from benign prostate hyperplasia and healthy men. Cancer Res., 62, 3609-3614.
    • (2002) Cancer Res. , vol.62 , pp. 3609-3614
    • Adam, B.-L.1
  • 2
    • 0141855279 scopus 로고    scopus 로고
    • A comprehensive approach to the analysis of matrix-assisted laser desorption/ionization-time of flight proteomics spectra from serum samples
    • Baggerly,K. et al. (2003) A comprehensive approach to the analysis of matrix-assisted laser desorption/ionization-time of flight proteomics spectra from serum samples. Proteomics, 3, 1667-1672.
    • (2003) Proteomics , vol.3 , pp. 1667-1672
    • Baggerly, K.1
  • 3
    • 1842559788 scopus 로고    scopus 로고
    • Reproducibility of seldi-tof protein patterns in serum comparing data sets from different experiments
    • Baggerly,K. et al. (2004) Reproducibility of seldi-tof protein patterns in serum comparing data sets from different experiments. Bioinformatics, 20, 777-785.
    • (2004) Bioinformatics , vol.20 , pp. 777-785
    • Baggerly, K.1
  • 4
    • 0141615786 scopus 로고    scopus 로고
    • Quality control peak finding for proteomics data collected from nipple aspirate fluid by surface-enhanced laser desorptoin ionization
    • Coombes,K. et al. (2003) Quality control and peak finding for proteomics data collected from nipple aspirate fluid by surface-enhanced laser desorptoin and ionization. Clin. Chem., 49, 1615-1623.
    • (2003) Clin. Chem. , vol.49 , pp. 1615-1623
    • Coombes, K.1
  • 5
    • 11144340579 scopus 로고    scopus 로고
    • Improved peak detection quantification of mass spectrometry data acquired from surface-enhanced laser desorption ionization by denoising spectra with the undecimated discrete wavelet transform
    • Technical Report M.D. Anderson Biostatistics Applied Mathematics Department
    • Coombes,K., Tsavachidis,S., Morris,J., Baggerly,K., Hung,M.-C., and Kuerer,H. (2004) Improved peak detection and quantification of mass spectrometry data acquired from surface-enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform. Technical Report, M.D. Anderson Biostatistics and Applied Mathematics Department.
    • (2004)
    • Coombes, K.1    Tsavachidis, S.2    Morris, J.3    Baggerly, K.4    Hung, M.-C.5    Kuerer, H.6
  • 6
    • 0003780150 scopus 로고
    • Nonparametric Regression Generalized Linear Models. A Roughness Penalty Approach
    • Chapman Hall London
    • Green,P. and Silverman,B. (1994) Nonparametric Regression and Generalized Linear Models. A Roughness Penalty Approach. Chapman and Hall, London.
    • (1994)
    • Green, P.1    Silverman, B.2
  • 8
    • 0036324715 scopus 로고    scopus 로고
    • Proteomics bioinformatics approaches for identification of serum biomarkers to detect breast cancer
    • Li,J. et al. (2002) Proteomics and bioinformatics approaches for identification of serum biomarkers to detect breast cancer. Clin. Chem., 48, 1296-1304.
    • (2002) Clin. Chem. , vol.48 , pp. 1296-1304
    • Li, J.1
  • 9
    • 0037381236 scopus 로고    scopus 로고
    • Mass spectrometry-based diagnostics: The upcoming revolution in disease detection
    • Petricoin,E. and Liotta,L. (2003) Mass spectrometry-based diagnostics: the upcoming revolution in disease detection. Clin. Chem., 49 533-534.
    • (2003) Clin. Chem. , vol.49 , pp. 533-534
    • Petricoin, E.1    Liotta, L.2
  • 10
    • 0037116832 scopus 로고    scopus 로고
    • Use of proteomic patterns in serum to identify ovarian cancer
    • Petricoin,E. et al. (2002) Use of proteomic patterns in serum to identify ovarian cancer. Lancet, 359, 572-577.
    • (2002) Lancet , vol.359 , pp. 572-577
    • Petricoin, E.1
  • 12
    • 26444597245 scopus 로고    scopus 로고
    • Normalization baseline correction alignment of high-throughput mass spectrometry data
    • 2004
    • Sauve,A. and Speed,T. (2004) Normalization, baseline correction and alignment of high-throughput mass spectrometry data. In Proceedings of the Genomic Signal Processing and Statistics, 2004.
    • (2004) Proceedings of the Genomic Signal Processing Statistics
    • Sauve, A.1    Speed, T.2
  • 13
    • 19944419092 scopus 로고    scopus 로고
    • Evaluation of serum protein profiling by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry for the detection of prostate cancer: I. Assessment of platform reproducibility
    • Semmes,O. et al. (2005) Evaluation of serum protein profiling by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry for the detection of prostate cancer: I. assessment of platform reproducibility. Clin. Chem., 51, 102-112.
    • (2005) Clin. Chem. , vol.51 , pp. 102-112
    • Semmes, O.1
  • 14
    • 0142008803 scopus 로고    scopus 로고
    • A data-analytic stratedgy for protein biomarker discovery: Profiling of high-dimensional proteomic data for cancer detection
    • Yasui,Y. et al. (2003) A data-analytic stratedgy for protein biomarker discovery: Profiling of high-dimensional proteomic data for cancer detection. Biostatistics, 4, 449-463.
    • (2003) Biostatistics , vol.4 , pp. 449-463
    • Yasui, Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.