-
1
-
-
0025770953
-
Core temperature measurement in the intensive care unit
-
Nierman DM: Core temperature measurement in the intensive care unit. Crit Care Med 1991; 19:818-823
-
(1991)
Crit Care Med
, vol.19
, pp. 818-823
-
-
Nierman, D.M.1
-
2
-
-
0031709718
-
Comparison of esophageal, rectal, axillary, bladder, tympanic, and pulmonary arterry temperatures in children
-
Robinson JL, Seal R, Spady D, et al: Comparison of esophageal, rectal, axillary, bladder, tympanic, and pulmonary arterry temperatures in children. J Pediatr 1998; 133: 553-556
-
(1998)
J Pediatr
, vol.133
, pp. 553-556
-
-
Robinson, J.L.1
Seal, R.2
Spady, D.3
-
3
-
-
0032735007
-
Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core tympanic, and oral methods
-
Giuliano KK, Scott S, Elliot S, et al: Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core tympanic, and oral methods. Crit Care Med 1999; 27:2307-2310
-
(1999)
Crit Care Med
, vol.27
, pp. 2307-2310
-
-
Giuliano, K.K.1
Scott, S.2
Elliot, S.3
-
4
-
-
0040675271
-
Monitoring urinary bladder temperature in the intensive care unit: State of the science
-
Fallis WM: Monitoring urinary bladder temperature in the intensive care unit: State of the science. Am J Crit Care 2002; 11:38-45
-
(2002)
Am J Crit Care
, vol.11
, pp. 38-45
-
-
Fallis, W.M.1
-
5
-
-
0037348764
-
Temperature measurement in intensive care patients: Comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core methods
-
Lefrant J-Y, Muller L, Coussaye JE, et al: Temperature measurement in intensive care patients: Comparison of urinary bladder, oesophageal, rectal, axillary, and inguinal methods versus pulmonary artery core methods. Intensive Care Med 2003; 29:414-418
-
(2003)
Intensive Care Med
, vol.29
, pp. 414-418
-
-
Lefrant, J.-Y.1
Muller, L.2
Coussaye, J.E.3
-
6
-
-
0025977593
-
Comparison of rectal, axillary, and tympanic membrane temperatures in infants and young children
-
Muma BK, Treloar DJ, Wurmlinger K, et al: Comparison of rectal, axillary, and tympanic membrane temperatures in infants and young children. Ann Emerg Med 1991; 20: 41-44
-
(1991)
Ann Emerg Med
, vol.20
, pp. 41-44
-
-
Muma, B.K.1
Treloar, D.J.2
Wurmlinger, K.3
-
7
-
-
0018137581
-
Thermometers and rectal perforation in the neonate
-
Frank JD, Brown S: Thermometers and rectal perforation in the neonate. Arch Dis Child 1978; 53:824-825
-
(1978)
Arch Dis Child
, vol.53
, pp. 824-825
-
-
Frank, J.D.1
Brown, S.2
-
8
-
-
0019774943
-
Rectal thermometer mediated cross infection with Salmonella wandsworth in a paediatric ward
-
Im SW, Chow K, Chau PY: Rectal thermometer mediated cross infection with Salmonella wandsworth in a paediatric ward. J Hosp Infect 1981; 2:171-174
-
(1981)
J Hosp Infect
, vol.2
, pp. 171-174
-
-
Im, S.W.1
Chow, K.2
Chau, P.Y.3
-
9
-
-
0024539811
-
Occult core hypothermia complicating cardiogenic shock
-
Buck SH, Zaritzky AL: Occult core hypothermia complicating cardiogenic shock. Pediatrics 1989; 83:782-783
-
(1989)
Pediatrics
, vol.83
, pp. 782-783
-
-
Buck, S.H.1
Zaritzky, A.L.2
-
10
-
-
0015518922
-
Rectal abscesses in cancer patients
-
Schimpff SC, Wiernik P, Block J: Rectal abscesses in cancer patients. Lancet 1972; 2:844-877
-
(1972)
Lancet
, vol.2
, pp. 844-877
-
-
Schimpff, S.C.1
Wiernik, P.2
Block, J.3
-
11
-
-
0025218457
-
Evaluation of an infrared tympanic membrane thermometer in pediatric patients
-
Kenney RD, Fortenberry JD, Surratt SS, et al: Evaluation of an infrared tympanic membrane thermometer in pediatric patients. Pediatrics 1990; 85:854-858
-
(1990)
Pediatrics
, vol.85
, pp. 854-858
-
-
Kenney, R.D.1
Fortenberry, J.D.2
Surratt, S.S.3
-
12
-
-
0026570755
-
Lack of agreement of tympanic membrane temperature assessments with conventional methods in a private practice setting
-
Freed GL, Fraley JK: Lack of agreement of tympanic membrane temperature assessments with conventional methods in a private practice setting. Pediatrics 1992; 89: 384-386
-
(1992)
Pediatrics
, vol.89
, pp. 384-386
-
-
Freed, G.L.1
Fraley, J.K.2
-
13
-
-
0027201177
-
Infrared tympanic membrane thermometry in the pediatric intensive care unit
-
Romano MJ, Fortenberry JD, Autrey E, et al: Infrared tympanic membrane thermometry in the pediatric intensive care unit. Crit Care Med 1993; 21:1181-1185
-
(1993)
Crit Care Med
, vol.21
, pp. 1181-1185
-
-
Romano, M.J.1
Fortenberry, J.D.2
Autrey, E.3
-
14
-
-
0037167250
-
Infrared ear thermometry compared with rectal thermometry in children: A systematic review
-
Craig JV, Lancaster G, Taylor S, et al: Infrared ear thermometry compared with rectal thermometry in children: A systematic review. Lancet 2002; 360(9333):603-609
-
(2002)
Lancet
, vol.360
, Issue.9333
, pp. 603-609
-
-
Craig, J.V.1
Lancaster, G.2
Taylor, S.3
-
15
-
-
0029957695
-
Modern electronic and chemical thermometers used in the axilla are inaccurate
-
Zengeya ST, Blumenthal I: Modern electronic and chemical thermometers used in the axilla are inaccurate. Eur J Pediatr 1996; 155:1005-1008
-
(1996)
Eur J Pediatr
, vol.155
, pp. 1005-1008
-
-
Zengeya, S.T.1
Blumenthal, I.2
-
16
-
-
0025738812
-
Axillary vs. rectal temperatures in ambulatory and hospitalized children
-
Weisse ME, Reagen MS, Boule L, et al: Axillary vs. rectal temperatures in ambulatory and hospitalized children. Pediatr Infect Dis J 1991; 10:541-542
-
(1991)
Pediatr Infect Dis J
, vol.10
, pp. 541-542
-
-
Weisse, M.E.1
Reagen, M.S.2
Boule, L.3
-
17
-
-
0032186446
-
Comparison of axillary and infrared tympanic membrane thermometry in a pediatric oncology outpatient setting
-
Androkoites AL, Werger A, Young M: Comparison of axillary and infrared tympanic membrane thermometry in a pediatric oncology outpatient setting. J Pediatr Oncol Nurs 1998; 15:216-222
-
(1998)
J Pediatr Oncol Nurs
, vol.15
, pp. 216-222
-
-
Androkoites, A.L.1
Werger, A.2
Young, M.3
-
18
-
-
0036637549
-
Comparison of temple temperature with rectal temperatures in children under two years of age
-
Siberry GK, Diener-West M, Schappell E, et al: Comparison of temple temperature with rectal temperatures in children under two years of age. Clin Pediatr 2002; 41:405-414
-
(2002)
Clin Pediatr
, vol.41
, pp. 405-414
-
-
Siberry, G.K.1
Diener-West, M.2
Schappell, E.3
-
19
-
-
0035096048
-
Accuracy of a non-invasive temporal artery thermometer for use in infants
-
Greenes DS, Fleisher GR: Accuracy of a non-invasive temporal artery thermometer for use in infants. Arch Pediatr Adolesc Med 2001; 155:376-381
-
(2001)
Arch Pediatr Adolesc Med
, vol.155
, pp. 376-381
-
-
Greenes, D.S.1
Fleisher, G.R.2
-
20
-
-
0037502292
-
Temporal artery measurement in healthy infants, children, and adolescents
-
Roy S, Powell K, Gerson LW: Temporal artery measurement in healthy infants, children, and adolescents. Clin Pediatr 2003; 42: 433-437
-
(2003)
Clin Pediatr
, vol.42
, pp. 433-437
-
-
Roy, S.1
Powell, K.2
Gerson, L.W.3
-
21
-
-
0033751668
-
Deep forehead temperature correlates well with blood temperature
-
Harioka T, Matsukawa T, Ozaki M, et al: Deep forehead temperature correlates well with blood temperature. Can J Anaesth 2000; 47: 980-983
-
(2000)
Can J Anaesth
, vol.47
, pp. 980-983
-
-
Harioka, T.1
Matsukawa, T.2
Ozaki, M.3
-
22
-
-
0002602476
-
Shock and multiorgan failure
-
Rogers M (Ed). Baltimore, Williams & Wilkins
-
Tobin J, Wetzel R: Shock and multiorgan failure. In: Textbook of Pediatric Intensive Care. Rogers M (Ed). Baltimore, Williams & Wilkins, 1996, p555
-
(1996)
Textbook of Pediatric Intensive Care
, pp. 555
-
-
Tobin, J.1
Wetzel, R.2
-
23
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland J, Altman D: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1(8476): 307-310
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.1
Altman, D.2
-
24
-
-
0032528036
-
On the comparison of correlated proportions for clustered data
-
Obuchowski NA: On the comparison of correlated proportions for clustered data. Stat Med 1998; 17:1495-1507
-
(1998)
Stat Med
, vol.17
, pp. 1495-1507
-
-
Obuchowski, N.A.1
-
25
-
-
3042830642
-
When body temperature changes, does rectal temperature lag behind?
-
Greenes DS, Fleisher GR: When body temperature changes, does rectal temperature lag behind? J Pediatr 2004; 144:824-826
-
(2004)
J Pediatr
, vol.144
, pp. 824-826
-
-
Greenes, D.S.1
Fleisher, G.R.2
-
26
-
-
0942289807
-
Estimating core temperature in infants and children after cardiac surgery: A comparison of six methods
-
Maxton FJ, Justin L, Gillies D: Estimating core temperature in infants and children after cardiac surgery: A comparison of six methods. J Adv Nurs 2004; 45:214-222
-
(2004)
J Adv Nurs
, vol.45
, pp. 214-222
-
-
Maxton, F.J.1
Justin, L.2
Gillies, D.3
|