메뉴 건너뛰기




Volumn 9, Issue 6, 2004, Pages 251-256

The use of a head-mounted display for visualization in neuroendoscopy

Author keywords

Ergonomics; Head mounted display; Neuroendoscopy; Surgical instrumentation; Visualization

Indexed keywords

ADULT; ANASTOMOSIS; ARTICLE; BRAIN CYST; CHILD; COLLOID CYST; COMPUTER ASSISTED SURGERY; ENDOSCOPE; ERGONOMICS; FIBEROSCOPE; HUMAN; INFANT; MAJOR CLINICAL STUDY; NEUROENDOSCOPY; PRIORITY JOURNAL; RETROSPECTIVE STUDY; TRANSSPHENOIDAL SURGERY;

EID: 24944570979     PISSN: 10929088     EISSN: 10970150     Source Type: Journal    
DOI: 10.1080/10929080500165476     Document Type: Article
Times cited : (23)

References (14)
  • 1
    • 0031885139 scopus 로고    scopus 로고
    • Endoscope-assisted brain surgery: Part I: Evolution, basic concept, and current technique
    • Perneczky A, Fries G. Endoscope-assisted brain surgery: Part I: Evolution, basic concept, and current technique. Neurosurgery 1998;42:219-25.
    • (1998) Neurosurgery , vol.42 , pp. 219-225
    • Perneczky, A.1    Fries, G.2
  • 2
    • 0031729774 scopus 로고    scopus 로고
    • Endoscopic neurosurgery and endoscope-assisted microneurosurgery for the treatment of intracranial cysts
    • Hopf NJ, Perneczky A. Endoscopic neurosurgery and endoscope-assisted microneurosurgery for the treatment of intracranial cysts. Neurosurgery 1998;43:1330-6.
    • (1998) Neurosurgery , vol.43 , pp. 1330-1336
    • Hopf, N.J.1    Perneczky, A.2
  • 3
    • 0033038020 scopus 로고    scopus 로고
    • Endoscopic third ventriculostomy: Outcome analysis of 100 consecutive procedures
    • Hopf NJ, Grunert P, Fries G, Resch KD, Perneczky A. Endoscopic third ventriculostomy: outcome analysis of 100 consecutive procedures. Neurosurgery 1999;44: 795-804.
    • (1999) Neurosurgery , vol.44 , pp. 795-804
    • Hopf, N.J.1    Grunert, P.2    Fries, G.3    Resch, K.D.4    Perneczky, A.5
  • 4
    • 0031964867 scopus 로고    scopus 로고
    • Laser-assisted neuroendoscopy using a neodymium-yttrium aluminum garnet or diode contact laser with pretreated fiber tips
    • Vandertop WP, Verdaasdonk RM, van Swol CFP. Laser-assisted neuroendoscopy using a neodymium-yttrium aluminum garnet or diode contact laser with pretreated fiber tips. J Neurosurg 1998;88:82-92.
    • (1998) J Neurosurg , vol.88 , pp. 82-92
    • Vandertop, W.P.1    Verdaasdonk, R.M.2    Van Swol, C.F.P.3
  • 5
    • 0031778319 scopus 로고    scopus 로고
    • Endoscopic endonasal transsphenoidal approach to the sella: Towards functional endoscopic pituitary surgery (FEPS)
    • Cappabianca P, Alfieri A, de Devitiis E. Endoscopic endonasal transsphenoidal approach to the sella: towards functional endoscopic pituitary surgery (FEPS). Minim Invas Neurosurg 1998;41:66-73.
    • (1998) Minim Invas Neurosurg , vol.41 , pp. 66-73
    • Cappabianca, P.1    Alfieri, A.2    De Devitiis, E.3
  • 6
    • 0030999304 scopus 로고    scopus 로고
    • Endoscopie endonasal transsphenoidal surgery: Experience with 50 patients
    • Jho H-D, Carrau RL. Endoscopie endonasal transsphenoidal surgery: experience with 50 patients. J Neurosurg 1997;87:44-51.
    • (1997) J Neurosurg , vol.87 , pp. 44-51
    • Jho, H.-D.1    Carrau, R.L.2
  • 7
    • 0034459502 scopus 로고    scopus 로고
    • Computer-aided/image-guided and video-endoscopic resection pituitary tumors
    • Pillay PK, Leo CW, Sethi DS. Computer-aided/image-guided and video-endoscopic resection pituitary tumors. Stereotact Funct Neurosurg 2000;74:203-9.
    • (2000) Stereotact Funct Neurosurg , vol.74 , pp. 203-209
    • Pillay, P.K.1    Leo, C.W.2    Sethi, D.S.3
  • 8
    • 0031928117 scopus 로고    scopus 로고
    • Stereoscopic head-mounted display incorporated into microsurgical procedures: Technical note
    • Levy ML, Chen JCT, Moffitt K, Corber Z, McComb JG. Stereoscopic head-mounted display incorporated into microsurgical procedures: technical note. Neurosurgery 1998;43:392-6.
    • (1998) Neurosurgery , vol.43 , pp. 392-396
    • Levy, M.L.1    Chen, J.C.T.2    Moffitt, K.3    Corber, Z.4    McComb, J.G.5
  • 10
    • 0030191825 scopus 로고    scopus 로고
    • Head-mounted video monitor for global visual access in mini-invasive surgery
    • Geis WP. Head-mounted video monitor for global visual access in mini-invasive surgery. Surg Endosc 1996;10:768-70.
    • (1996) Surg Endosc , vol.10 , pp. 768-770
    • Geis, W.P.1
  • 11
    • 0032792280 scopus 로고    scopus 로고
    • The 3-D monitor and head-mounted display. A quantitative evaluation of advanced laparoscopic viewing technologies
    • Herron DM, Lantis JC II, Maykel J, Basu C, Schwaitzberg SD. The 3-D monitor and head-mounted display. A quantitative evaluation of advanced laparoscopic viewing technologies. Surg Endosc 1999;13:751-5.
    • (1999) Surg Endosc , vol.13 , pp. 751-755
    • Herron, D.M.1    Lantis II, J.C.2    Maykel, J.3    Basu, C.4    Schwaitzberg, S.D.5
  • 12
    • 0031831060 scopus 로고    scopus 로고
    • The visual effects of head-mounted display (HMD) are not distinguishable from those of desk-top computer display
    • Peli E. The visual effects of head-mounted display (HMD) are not distinguishable from those of desk-top computer display. Visual Research 1998;38:2053-66.
    • (1998) Visual Research , vol.38 , pp. 2053-2066
    • Peli, E.1
  • 13
    • 0033081886 scopus 로고    scopus 로고
    • Physical ergonomics of virtual environment use
    • Nichols S. Physical ergonomics of virtual environment use. Applied Ergonomics 1999;30:79-90.
    • (1999) Applied Ergonomics , vol.30 , pp. 79-90
    • Nichols, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.