메뉴 건너뛰기




Volumn 3504, Issue , 2005, Pages 133-142

Supporting the TECAB grafting through CT based analysis of coronary arteries

Author keywords

Calcification detection; Cardiac imaging; Computed tomography; Coronary arteries; Minimally invasive surgery; Vessel segmentation

Indexed keywords

BLOOD VESSEL PROSTHESES; CALCIFICATION (BIOCHEMISTRY); CARDIOLOGY; CARDIOVASCULAR SURGERY; ENDOSCOPY; TISSUE;

EID: 24944566685     PISSN: 03029743     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/11494621_14     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 2
    • 0036621229 scopus 로고    scopus 로고
    • Totally endoscopic coronary artery bypass grafting on cardiopulmonary bypass with robotically enhanced telemanipulation: Report of forty-five Cases
    • Dogan, S., Aybek, T., Andreßen, E., Byhahn, C., Mierdl, S., Westphal, K., Matheis, G., Moritz, A., Wimmer-Greinecker, G.: Totally Endoscopic Coronary Artery Bypass Grafting on Cardiopulmonary Bypass with Robotically Enhanced Telemanipulation: Report of forty-five Cases. J Thorac Cardiovasc Surg 123 (2002) 1125-1131
    • (2002) J Thorac Cardiovasc Surg , vol.123 , pp. 1125-1131
    • Dogan, S.1    Aybek, T.2    Andreßen, E.3    Byhahn, C.4    Mierdl, S.5    Westphal, K.6    Matheis, G.7    Moritz, A.8    Wimmer-Greinecker, G.9
  • 5
    • 0031720879 scopus 로고    scopus 로고
    • Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method
    • Callister, T.Q., Cooil, B., Raya, S.P., Lippolis, N.J., Russo, D.J., Raggi, P.: Coronary Artery Disease: Improved Reproducibility of Calcium Scoring with an Electron-Beam CT Volumetric Method. Radiology 208 (1998) 807-814
    • (1998) Radiology , vol.208 , pp. 807-814
    • Callister, T.Q.1    Cooil, B.2    Raya, S.P.3    Lippolis, N.J.4    Russo, D.J.5    Raggi, P.6
  • 6
    • 0002331464 scopus 로고    scopus 로고
    • Non-invasive cardiac imaging with fast multi-slice cardio CT
    • Siemens AG, Medical Engineering
    • Ohnesorge, B., Flohr, T.: Non-Invasive Cardiac Imaging with Fast Multi-Slice Cardio CT. electromedica 68, Siemens AG, Medical Engineering (2000)
    • (2000) Electromedica , vol.68
    • Ohnesorge, B.1    Flohr, T.2
  • 7
    • 4644350529 scopus 로고    scopus 로고
    • Non-Invasive coronary angiography with multislice computed tomography. Technology, methods, preliminary experience and prospects
    • Traversi, E., Bertoli, G., Barazzoni, G., Baldi, M., Tramarin, R.: Non-Invasive coronary angiography with multislice computed tomography. Technology, methods, preliminary experience and prospects. Ital Heart J 5 (2004) 89-98
    • (2004) Ital Heart J , vol.5 , pp. 89-98
    • Traversi, E.1    Bertoli, G.2    Barazzoni, G.3    Baldi, M.4    Tramarin, R.5
  • 12
    • 5644239688 scopus 로고    scopus 로고
    • Segmentation of vessels: The corkscrew algorithm
    • Robert L. Galloway, J.E., ed.: Medical Imaging Symposium 2004
    • Wesarg, S., Firle, E.A.: Segmentation of Vessels: The Corkscrew Algorithm. In Robert L. Galloway, J.E., ed.: Medical Imaging Symposium 2004. Volume 5370 of Proc. of SPIE. (2004) 1609-1620
    • (2004) Proc. of SPIE , vol.5370 , pp. 1609-1620
    • Wesarg, S.1    Firle, E.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.