메뉴 건너뛰기




Volumn 16, Issue 9, 2005, Pages 1237-1240

Comparison or recirculation percentage of the palindrome catheter and standard hemodialysis catheters in a swine model

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BLOOD FLOW; BLOOD FLOW VELOCITY; CATHETER; CONTROLLED STUDY; ECHOGRAPHY; HEART RIGHT ATRIUM; HEMODIALYSIS; MALE; NONHUMAN; PERISTALTIC PUMP; PRIORITY JOURNAL; SUPERIOR CAVA VEIN;

EID: 24944558001     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.RVI.0000171700.45582.9E     Document Type: Article
Times cited : (43)

References (11)
  • 2
    • 84907127189 scopus 로고
    • Recirculation: A uremic syndrome complicating the use of prosthetic arteriovenous fistulas for hemodialysis
    • Warren S, O'Conner D, Steinberg S. Recirculation: a uremic syndrome complicating the use of prosthetic arteriovenous fistulas for hemodialysis. J Dialysis 1978; 2:251-259.
    • (1978) J Dialysis , vol.2 , pp. 251-259
    • Warren, S.1    O'Conner, D.2    Steinberg, S.3
  • 3
    • 0346059625 scopus 로고    scopus 로고
    • Blood flow and recirculation rates in tunneled hemodialysis catheters
    • Senecal L, Saint-Sauveur E, Leblanc M. Blood flow and recirculation rates in tunneled hemodialysis catheters. ASAIO J 2004; 50:94-97.
    • (2004) ASAIO J , vol.50 , pp. 94-97
    • Senecal, L.1    Saint-Sauveur, E.2    Leblanc, M.3
  • 4
    • 0027064655 scopus 로고
    • The determination of hemodialysis blood recirculation using blood urea nitrogen measurements
    • Hester RL, Curry E, Bower J. The determination of hemodialysis blood recirculation using blood urea nitrogen measurements. Am J Kidney Disease 1992; 6:598-602.
    • (1992) Am J Kidney Disease , vol.6 , pp. 598-602
    • Hester, R.L.1    Curry, E.2    Bower, J.3
  • 5
    • 0029048487 scopus 로고
    • Theory and validation of access flow measurement by dilution technique during hemodialysis
    • Krivitski NM. Theory and validation of access flow measurement by dilution technique during hemodialysis. Kidney Int 1995; 48:244-250.
    • (1995) Kidney Int , vol.48 , pp. 244-250
    • Krivitski, N.M.1
  • 8
    • 0024539684 scopus 로고
    • Successful use of double lumen, silicone rubber catheters for permanent hemodialysis access
    • Shusterman NH, Kloss K, Mullen JL. Successful use of double lumen, silicone rubber catheters for permanent hemodialysis access. Kidney International 1989; 35:887-890.
    • (1989) Kidney International , vol.35 , pp. 887-890
    • Shusterman, N.H.1    Kloss, K.2    Mullen, J.L.3
  • 9
    • 0031906208 scopus 로고    scopus 로고
    • Effective blood flow and recirculation rates in internal jugular vein twin catheter: Measurement by ultrasound velocity dilution
    • Leblanc M, Bosc J, Vausennat F, et al. Effective blood flow and recirculation rates in internal jugular vein twin catheter: measurement by ultrasound velocity dilution. Am J Kid Dis 1998; 31:87-92.
    • (1998) Am J Kid Dis , vol.31 , pp. 87-92
    • Leblanc, M.1    Bosc, J.2    Vausennat, F.3
  • 10
    • 0030746516 scopus 로고    scopus 로고
    • Long term performance and complications of the Tesio twin catheter system for hemodialysis access
    • Prabhu PN, Kerns SR, Sabetelli FW, et al. Long term performance and complications of the Tesio twin catheter system for hemodialysis access. Am J Kid Dis 1997; 30:213-218.
    • (1997) Am J Kid Dis , vol.30 , pp. 213-218
    • Prabhu, P.N.1    Kerns, S.R.2    Sabetelli, F.W.3
  • 11
    • 0036558888 scopus 로고    scopus 로고
    • Effect of reversal of catheter ports on it recirculation: Comparison of the Perm-Cath with the Tesio twin catheter
    • Hassan HA, Frenchie DL, Bastani B. Effect of reversal of catheter ports on it recirculation: comparison of the Perm-Cath with the Tesio twin catheter, ASAIO J 2002; 48:316-319.
    • (2002) ASAIO J , vol.48 , pp. 316-319
    • Hassan, H.A.1    Frenchie, D.L.2    Bastani, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.