메뉴 건너뛰기




Volumn 91, Issue 5, 2005, Pages 465-469

Percutaneous compression plate for pertrochanteric fixation of hip fractures: Surgical technique and first results;Ostéosynthèse des fractures du massif trochantérien par plaque de compression percutanée: Technique chirurgicale et premiers résultats

Author keywords

Percutaneous compression plate; Pertrochanteric fractures

Indexed keywords

APONEUROSIS; ARTICLE; BONE PLATE; CHILD; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FRACTURE FIXATION; FRACTURE REDUCTION; HIP FRACTURE; HUMAN; MALE; MINIMALLY INVASIVE SURGERY; MUSCLE INJURY; OPERATION DURATION; OSTEOSYNTHESIS; POSTOPERATIVE PERIOD; TENSOR FASCIA LATA MUSCLE; VASTUS LATERALIS MUSCLE; WEIGHT BEARING;

EID: 24944501787     PISSN: 00351040     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0035-1040(05)84364-8     Document Type: Article
Times cited : (3)

References (13)
  • 1
    • 0034279730 scopus 로고    scopus 로고
    • Percutaneous compression plating of intertrochanteric hip fractures
    • GOTFRIED Y: Percutaneous compression plating of intertrochanteric hip fractures. J Orthop Trauma, 2000, 14, 490-495.
    • (2000) J Orthop Trauma , vol.14 , pp. 490-495
    • Gotfried, Y.1
  • 3
    • 0031773315 scopus 로고    scopus 로고
    • Fractures du massif trochantérien traitées par vis plaque DHS: Mesure du glissement selon le type anatomique de fracture
    • OGER P, KATZ V, LECORRE N, BEAUFILS P: Fractures du massif trochantérien traitées par vis plaque DHS: mesure du glissement selon le type anatomique de fracture. Rev Chir Orthop, 1998, 84, 539-545.
    • (1998) Rev Chir Orthop , vol.84 , pp. 539-545
    • Oger, P.1    Katz, V.2    Lecorre, N.3    Beaufils, P.4
  • 4
    • 0027755888 scopus 로고
    • Le clou gamma dans le traitement à foyer fermé des fractures trochantériennes. Résultat et indications à propos d'une série de 121 cas
    • KEMPF I, GROSSE A, TAGLANG G, FAVREUL E: Le clou gamma dans le traitement à foyer fermé des fractures trochantériennes. Résultat et indications à propos d'une série de 121 cas. Rev Chir Orthop, 1993, 79, 29-40.
    • (1993) Rev Chir Orthop , vol.79 , pp. 29-40
    • Kempf, I.1    Grosse, A.2    Taglang, G.3    Favreul, E.4
  • 5
    • 0036796998 scopus 로고    scopus 로고
    • Biomechanical evaluation of the percutaneous compression plating system for hip fractures
    • GOTFRIED Y, COHEN B, ROTEM A: Biomechanical evaluation of the percutaneous compression plating system for hip fractures. J Orthop Trauma, 2002, 16, 644-650.
    • (2002) J Orthop Trauma , vol.16 , pp. 644-650
    • Gotfried, Y.1    Cohen, B.2    Rotem, A.3
  • 6
    • 0036189124 scopus 로고    scopus 로고
    • The Gotfried percutaneous compression plate versus the dynamic hip screw in the treatment of pertrochanteric hip fractures: Minimal invasive treatment reduces operative time and postoperative pain
    • JANZING HM, HOUBEN BJ, BRANDT SE, CHOEURN V, LEFEVER S, BROOS P et al.: The Gotfried percutaneous compression plate versus the dynamic hip screw in the treatment of pertrochanteric hip fractures: minimal invasive treatment reduces operative time and postoperative pain. J Orthop Trauma, 2002, 52, 293-298.
    • (2002) J Orthop Trauma , vol.52 , pp. 293-298
    • Janzing, H.M.1    Houben, B.J.2    Brandt, S.E.3    Choeurn, V.4    Lefever, S.5    Broos, P.6
  • 7
    • 0036064177 scopus 로고    scopus 로고
    • Pertrochanteric fractures: Is there an advantage to an intramedullary nail? A randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail
    • SAUDAN M, LUBBEKE A, SADOWSKI C, RIAND N, STERN R, HOFFMEYER P: Pertrochanteric fractures: is there an advantage to an intramedullary nail? A randomized, prospective study of 206 patients comparing the dynamic hip screw and proximal femoral nail. J Orthop Trauma, 2002, 16, 386-393.
    • (2002) J Orthop Trauma , vol.16 , pp. 386-393
    • Saudan, M.1    Lubbeke, A.2    Sadowski, C.3    Riand, N.4    Stern, R.5    Hoffmeyer, P.6
  • 8
    • 0036626988 scopus 로고    scopus 로고
    • Percutaneous compression plating for intertrochanteric hip fractures: Treatment rationale
    • GOTFRIED Y: Percutaneous compression plating for intertrochanteric hip fractures: treatment rationale. Orthopedics, 2002, 25, 647-652.
    • (2002) Orthopedics , vol.25 , pp. 647-652
    • Gotfried, Y.1
  • 11
    • 0036151151 scopus 로고    scopus 로고
    • The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip
    • KOSYGAN KP, MOHAN R, NEWMAN RJ: The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip. J Bone Joint Surg (Br), 2002, 84, 19-22.
    • (2002) J Bone Joint Surg (Br) , vol.84 , pp. 19-22
    • Kosygan, K.P.1    Mohan, R.2    Newman, R.J.3
  • 12
    • 0036298615 scopus 로고    scopus 로고
    • Percutaneous compression plating (PC.C.P) versus the dynamic hip screw for pertrochanteric hip fractures: Preliminary results
    • BRANDT SE, LEFEVER S, JANZING HM, BROOS PL, PILOT P, HOUBEN BJ: Percutaneous compression plating (PC.C.P) versus the dynamic hip screw for pertrochanteric hip fractures: preliminary results. Injury, 2002, 33, 413-418.
    • (2002) Injury , vol.33 , pp. 413-418
    • Brandt, S.E.1    Lefever, S.2    Janzing, H.M.3    Broos, P.L.4    Pilot, P.5    Houben, B.J.6
  • 13
    • 1542328214 scopus 로고    scopus 로고
    • Osteosynthesis of trochanteric fracture with percutaneus compression plate (PC.C.P)
    • BERKENBAUM I, EL BANNA S: Osteosynthesis of trochanteric fracture with percutaneus compression plate (PC.C.P). Rev Med Brux, 2004, 25, 40-46.
    • (2004) Rev Med Brux , vol.25 , pp. 40-46
    • Berkenbaum, I.1    El Banna, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.