메뉴 건너뛰기




Volumn 33, Issue 5, 2005, Pages 295-304

Improvement to X-ray piping diagnostic system through simulation (measuring thickness of piping containing rust)

Author keywords

EGS4; Nondestructive inspection; Pipe; Remaining years; Rust; Simulation; X rays

Indexed keywords

BUILDINGS; CORROSION; INSPECTION; NONDESTRUCTIVE EXAMINATION; PIPE; SIMULATION; STEEL; X RAY ANALYSIS; X RAY RADIOGRAPHY; X RAYS;

EID: 24944499840     PISSN: 00903973     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (5)
  • 1
    • 0032121244 scopus 로고    scopus 로고
    • X-ray piping diagnostic system
    • Kajiwara, G., "X-ray Piping Diagnostic System," Journal of Testing and Evaluation, Vol. 26, No. 4, 1998, pp. 346-351.
    • (1998) Journal of Testing and Evaluation , vol.26 , Issue.4 , pp. 346-351
    • Kajiwara, G.1
  • 2
    • 24944568034 scopus 로고    scopus 로고
    • Examination of the X-ray piping diagnostic system using EGS4
    • KEK Proceedings 98-7
    • Kajiwara, G., "Examination of the X-ray Piping Diagnostic System Using EGS4," Proceedings of the Seventh EGS4 Users' Meeting in Japan, KEK Proceedings 98-7, 1998, pp. 86-93.
    • (1998) Proceedings of the Seventh EGS4 Users' Meeting in Japan , pp. 86-93
    • Kajiwara, G.1
  • 3
    • 24944463959 scopus 로고    scopus 로고
    • Examination of the X-ray piping diagnostic system using EGS4 In case considering spectrum of X-ray
    • KEK Proceedings 99-15
    • Kajiwara, G., "Examination of the X-ray Piping Diagnostic System Using EGS4 (In case Considering Spectrum of X-ray," Proceedings of the Eighth EGS4 Users' Meeting in Japan, KEK Proceedings 99-15, 1999, pp. 71-75.
    • (1999) Proceedings of the Eighth EGS4 Users' Meeting in Japan , pp. 71-75
    • Kajiwara, G.1
  • 4
    • 3342928002 scopus 로고    scopus 로고
    • Examination of the X-ray piping diagnos tic system using EGS4 (examination of the film and iron rust)
    • KEK Proceedings 2000-20
    • Kajiwara, G., "Examination of the X-ray Piping Diagnos tic System Using EGS4 (Examination of the Film and Iron Rust)," Proceedings of the Second International Workshop on EGS4, KEK Proceedings 2000-20, 2000, pp. 115-119.
    • (2000) Proceedings of the Second International Workshop on EGS4 , pp. 115-119
    • Kajiwara, G.1
  • 5
    • 24944432910 scopus 로고    scopus 로고
    • Examination of the X-ray piping diagnostic system using EGS4 measuring the thickness of a steel pipe with rust
    • KEK Proceedings 2001-22
    • Kajiwara, G., "Examination of the X-ray Piping Diagnostic System Using EGS4 (Measuring the Thickness of a Steel Pipe with Rust," Proceedings of the Ninth EGS4 Users' Meeting in Japan, KEK Proceedings 2001-22, 2001, pp. 15-18.
    • (2001) Proceedings of the Ninth EGS4 Users' Meeting in Japan , pp. 15-18
    • Kajiwara, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.