메뉴 건너뛰기




Volumn 32, Issue 3, 2005, Pages 399-401

A successful anticoagulation protocol for the first HeartMate® II implantation in the United States

Author keywords

Activated partial thromboplastin time; Anticoagulants administration and dosage; Blood coagulation tests; Cardiac surgical procedures; Heart assist devices; Human; Male; Monitoring, physiologic instrumentation; Platelet function tests; Prothrombin time

Indexed keywords

ACETYLSALICYLIC ACID; DIPYRIDAMOLE; HEPARIN; INOTROPIC AGENT; WARFARIN;

EID: 24944489350     PISSN: 07302347     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (40)

References (7)
  • 1
    • 0037636659 scopus 로고    scopus 로고
    • Left ventricular assist devices and bleeding: Adding insult to injury
    • Goldstein DJ, Beauford RB. Left ventricular assist devices and bleeding: adding insult to injury. Ann Thorac Surg 2003; 75(6 Suppl):S42-7.
    • (2003) Ann Thorac Surg , vol.75 , Issue.6 SUPPL.
    • Goldstein, D.J.1    Beauford, R.B.2
  • 2
    • 0034669834 scopus 로고    scopus 로고
    • Frequency, risk factors, and clinical outcomes of left ventricular assist device-associated ventricular thrombus
    • Reilly MP, Wiegers SE, Cucchiara AJ, O'Hara ML, Plappert TJ, Loh E, et al. Frequency, risk factors, and clinical outcomes of left ventricular assist device-associated ventricular thrombus. Am J Cardiol 2000;86:1156-9, A10.
    • (2000) Am J Cardiol , vol.86 , pp. 1156-1159
    • Reilly, M.P.1    Wiegers, S.E.2    Cucchiara, A.J.3    O'Hara, M.L.4    Plappert, T.J.5    Loh, E.6
  • 3
    • 0036507948 scopus 로고    scopus 로고
    • Effect of low-molecular weight dextran sulfate on coagulation and platelet function tests
    • Zeerleder S, Mauron T, Lammle B, Wuillemin WA. Effect of low-molecular weight dextran sulfate on coagulation and platelet function tests. Thromb Res 2002;105:441-6.
    • (2002) Thromb Res , vol.105 , pp. 441-446
    • Zeerleder, S.1    Mauron, T.2    Lammle, B.3    Wuillemin, W.A.4
  • 4
    • 0034085513 scopus 로고    scopus 로고
    • Hemostatic product transfusions and adverse outcomes: Focus on point-of-care testing to reduce transfusion need
    • discussion 37-8
    • von Kier S, Smith A. Hemostatic product transfusions and adverse outcomes: focus on point-of-care testing to reduce transfusion need. J Cardiothorac Vase Anesth 2000;14(3 Suppl 1):15-21; discussion 37-8.
    • (2000) J Cardiothorac Vase Anesth , vol.143 , Issue.SUPPL. 1 , pp. 15-21
    • Von Kier, S.1    Smith, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.