메뉴 건너뛰기




Volumn 3504, Issue , 2005, Pages 434-445

Tracking of LV endocardial surface on real-time three-dimensional ultrasound with optical flow

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD VESSELS; CARDIOLOGY; COMPUTATIONAL GEOMETRY; PRESSURE EFFECTS; REAL TIME SYSTEMS; THREE DIMENSIONAL COMPUTER GRAPHICS; VISUALIZATION;

EID: 24944483066     PISSN: 03029743     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/11494621_43     Document Type: Conference Paper
Times cited : (17)

References (32)
  • 1
    • 0028046816 scopus 로고
    • Three-dimensional and four-dimensional echocardiography
    • E. O. Ofili and N. C. Nanda, "Three-Dimensional and Four-Dimensional Echocardiography," Ultrasound Medical Biology, vol. 20, 1994.
    • (1994) Ultrasound Medical Biology , vol.20
    • Ofili, E.O.1    Nanda, N.C.2
  • 3
    • 0027490323 scopus 로고
    • Three-dimensional sonographic reconstruction: Technique and diagnostic applications
    • R. N. Rankin, A. Fenster, et al., "Three-Dimensional Sonographic Reconstruction: Technique and Diagnostic Applications," American Journal of Radiology, vol. 161, pp. 695-702, 1993.
    • (1993) American Journal of Radiology , vol.161 , pp. 695-702
    • Rankin, R.N.1    Fenster, A.2
  • 4
    • 0027526385 scopus 로고
    • Three- and four-dimensional cardiovascular ultrasound imaging: A new era for echocardiography
    • M. Belohlavek, D. A. Foley, et al., "Three- and Four-Dimensional Cardiovascular Ultrasound Imaging: A New Era for Echocardiography," Mayo Clinic Proceedings, vol. 68, pp. 221-240, 1993.
    • (1993) Mayo Clinic Proceedings , vol.68 , pp. 221-240
    • Belohlavek, M.1    Foley, D.A.2
  • 5
    • 0025515954 scopus 로고
    • Real time volumetric ultrasound imaging system
    • O. T. V. Ramm and S. W. Smith, "Real Time Volumetric Ultrasound Imaging System," Journal of Digital Imaging, vol. 3, pp. 261-266, 1990.
    • (1990) Journal of Digital Imaging , vol.3 , pp. 261-266
    • Ramm, O.T.V.1    Smith, S.W.2
  • 9
    • 0032034224 scopus 로고    scopus 로고
    • Segmentation and tracking in echocardiographic sequences: Active contours guided by optical flow estimates
    • I. Mikic, S. Krucinski, et al., "Segmentation and Tracking in Echocardiographic Sequences: Active Contours Guided by Optical Flow Estimates," IEEE Trans Med Imaging, vol. 17, pp. 274-284, 1998.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 274-284
    • Mikic, I.1    Krucinski, S.2
  • 10
    • 4644299898 scopus 로고    scopus 로고
    • Velocity estimation in ultrasound images: A block matching approach
    • D. Boukerroui, J. A. Noble, et al., "Velocity Estimation in Ultrasound Images: A Block Matching Approach," in Lecture Notes in Computer Science, 2003, pp. 586-598.
    • (2003) Lecture Notes in Computer Science , pp. 586-598
    • Boukerroui, D.1    Noble, J.A.2
  • 11
    • 24944538191 scopus 로고    scopus 로고
    • Motion analysis of 3d ultrasound texture patterns
    • W. Yu, N. Lin, et al., "Motion Analysis of 3d Ultrasound Texture Patterns," in Lecture Notes in Computer Science, 2003, pp. 252-261.
    • (2003) Lecture Notes in Computer Science , pp. 252-261
    • Yu, W.1    Lin, N.2
  • 12
    • 0042172841 scopus 로고    scopus 로고
    • A level set approach for shape-driven segmentation and tracking of the left ventricle
    • N. Paragios, "A Level Set Approach for Shape-Driven Segmentation and Tracking of the Left Ventricle," IEEE Trans Med Imaging, vol. 22, pp. 773-776, 2003.
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 773-776
    • Paragios, N.1
  • 13
    • 0030153643 scopus 로고    scopus 로고
    • Tracking and motion analysis of the left ventricle with deformable superquadratics
    • E. Bardinet, L. D. Cohen, et al., "Tracking and Motion Analysis of the Left Ventricle with Deformable Superquadratics," Med Image Analysis, vol. 1, pp. 129-149, 1996.
    • (1996) Med Image Analysis , vol.1 , pp. 129-149
    • Bardinet, E.1    Cohen, L.D.2
  • 14
    • 1342344969 scopus 로고    scopus 로고
    • The combined effect of nonlinear filtration and window size on the accuracy of tissue displacement estimation using detected echo signals
    • V. Behar, D. Adam, et al., "The Combined Effect of Nonlinear Filtration and Window Size on the Accuracy of Tissue Displacement Estimation Using Detected Echo Signals," Ultrasonics, vol. 41, pp. 743-753, 2004.
    • (2004) Ultrasonics , vol.41 , pp. 743-753
    • Behar, V.1    Adam, D.2
  • 15
    • 0037767506 scopus 로고    scopus 로고
    • A new method for analysis of motion of carotid plaques from Rf ultrasound images
    • J. Bang, T. Dahl, et al, "A New Method for Analysis of Motion of Carotid Plaques from Rf Ultrasound Images," Ultrasound Med Biol, vol. 29, pp. 967-976, 2003.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 967-976
    • Bang, J.1    Dahl, T.2
  • 16
    • 0036277861 scopus 로고    scopus 로고
    • Ultrasound-based vessel wall tracking: An auto-correlation technique with Rf center frequency estimation
    • S. I. Rabben, S. Bjaerum, et al., "Ultrasound-Based Vessel Wall Tracking: An Auto-Correlation Technique with Rf Center Frequency Estimation," Ultrasound Med Biol, vol. 28, pp. 507-517, 2002.
    • (2002) Ultrasound Med Biol , vol.28 , pp. 507-517
    • Rabben, S.I.1    Bjaerum, S.2
  • 17
    • 4143109284 scopus 로고    scopus 로고
    • Deformation imaging by ultrasound for the assessment of regional myocardial function
    • Honolulu, HI, USA
    • J. D'Hooge, P. Claus, et al., "Deformation Imaging by Ultrasound for the Assessment of Regional Myocardial Function," 2003 IEEE Ultrasonics Symposium, Honolulu, HI, USA, 2003.
    • (2003) 2003 IEEE Ultrasonics Symposium
    • D'Hooge, J.1    Claus, P.2
  • 18
    • 4143136590 scopus 로고    scopus 로고
    • Myocardial elastography - Comparison to results using Mr cardiac tagging
    • Honolulu, HI, United States
    • E. E. Konofagou, W. Manning, et al., "Myocardial Elastography - Comparison to Results Using Mr Cardiac Tagging," 2003 IEEE Ultrasonics Symposium, Honolulu, HI, United States, 2003.
    • (2003) 2003 IEEE Ultrasonics Symposium
    • Konofagou, E.E.1    Manning, W.2
  • 23
    • 0020642324 scopus 로고
    • Displacement vectors derived from second-order intensity variations in image sequences
    • H. Nagel, "Displacement Vectors Derived from Second-Order Intensity Variations in Image Sequences," Computer Vision Graphics Image Processing, vol. 21, pp. 85-117, 1983.
    • (1983) Computer Vision Graphics Image Processing , vol.21 , pp. 85-117
    • Nagel, H.1
  • 24
    • 34250087462 scopus 로고
    • A computational framework and an algorithm for the measurement of visual motion
    • P. Anandan, "A Computational Framework and an Algorithm for the Measurement of Visual Motion," International Journal of Computer Vision, vol. 2, pp. 283-310, 1989.
    • (1989) International Journal of Computer Vision , vol.2 , pp. 283-310
    • Anandan, P.1
  • 26
    • 0028378716 scopus 로고
    • Performance of optical flow techniques
    • J. L. Barron, D. Fleet, et al, "Performance of Optical Flow Techniques," Int. J of Computer Vision, vol. 12, pp. 43-77, 1994.
    • (1994) Int. J of Computer Vision , vol.12 , pp. 43-77
    • Barron, J.L.1    Fleet, D.2
  • 27
    • 12144265943 scopus 로고    scopus 로고
    • Assessment of visual quality and spatial accuracy of fast anisotropie diffusion and scan conversion algorithms for real-time three-dimensional spherical ultrasound
    • San Diego, CA, USA
    • Q. Duan, E. D. Angelini, et al., "Assessment of Visual Quality and Spatial Accuracy of Fast Anisotropie Diffusion and Scan Conversion Algorithms for Real-Time Three-Dimensional Spherical Ultrasound," SPIE International Symposium Medical Imaging, San Diego, CA, USA, 2004.
    • (2004) SPIE International Symposium Medical Imaging
    • Duan, Q.1    Angelini, E.D.2
  • 29
    • 0036945524 scopus 로고    scopus 로고
    • Comparison of segmentation methods for analysis of endocardial wall motion with real-time three-dimensional ultrasound
    • Memphis TN, USA
    • E. D. Angelini, D. Hamming, et al., "Comparison of Segmentation Methods for Analysis of Endocardial Wall Motion with Real-Time Three-Dimensional Ultrasound," Computers in Cardiology, Memphis TN, USA, 2002.
    • (2002) Computers in Cardiology
    • Angelini, E.D.1    Hamming, D.2
  • 31
    • 0018649968 scopus 로고
    • Left ventricular volume from paired biplane two-dimensional echocardiography
    • N. B. Schiller, H. Acquatella, et al., "Left Ventricular Volume from Paired Biplane Two-Dimensional Echocardiography," Circulation, vol. 60, pp. 547-555, 1979.
    • (1979) Circulation , vol.60 , pp. 547-555
    • Schiller, N.B.1    Acquatella, H.2
  • 32
    • 0018679823 scopus 로고
    • Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. A comparison of cineangiographic and radionuclide techniques
    • E. D. Folland, A. F. Parisi, et al., "Assessment of Left Ventricular Ejection Fraction and Volumes by Real-Time, Two-Dimensional Echocardiography. A Comparison of Cineangiographic and Radionuclide Techniques," Circulation, vol. 60, pp. 760-766, 1979.
    • (1979) Circulation , vol.60 , pp. 760-766
    • Folland, E.D.1    Parisi, A.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.