메뉴 건너뛰기




Volumn 199, Issue 5, 2005, Pages 275-277

C-Arm for accurate reduction of zygomatic arch fracture - A case report

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CASE REPORT; HUMAN; INSTRUMENTATION; INTERVENTIONAL RADIOLOGY; MALE; OSTEOSYNTHESIS; PATIENT MONITORING; RADIATION PROTECTION; RADIOGRAPHY; ZYGOMA ARCH FRACTURE;

EID: 24944478993     PISSN: 00070610     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.bdj.4812652     Document Type: Article
Times cited : (12)

References (7)
  • 1
    • 0023390851 scopus 로고
    • Stabilisation of the delayed zygomatic arch fracture
    • Guven O. Stabilisation of the delayed zygomatic arch fracture. Int J Oral Maxillofac. Surg 1987; 16: 445-447.
    • (1987) Int J Oral Maxillofac Surg , vol.16 , pp. 445-447
    • Guven, O.1
  • 4
    • 0025035678 scopus 로고
    • Ultrasonographic evaluation during reduction of zygomatic arch fractures
    • Akizuki H, Yoshida H, Michi K. Ultrasonographic evaluation during reduction of zygomatic arch fractures. J Craniomaxillofac Surg 1990; 18: 263-266.
    • (1990) J Craniomaxillofac Surg , vol.18 , pp. 263-266
    • Akizuki, H.1    Yoshida, H.2    Michi, K.3
  • 5
    • 0035242156 scopus 로고    scopus 로고
    • Intraoperative computed tomography with the mobile CT Tomoscan M during surgical treatment of orbital fractures
    • Hoelzle F, Klein M, Schwerdtner O, et al. Intraoperative computed tomography with the mobile CT Tomoscan M during surgical treatment of orbital fractures. Int J Oral Maxillofac Surg 2001; 30: 26-31.
    • (2001) Int J Oral Maxillofac Surg , vol.30 , pp. 26-31
    • Hoelzle, F.1    Klein, M.2    Schwerdtner, O.3
  • 6
    • 24944446903 scopus 로고    scopus 로고
    • Ionising Radiation (Medical Exposure) Regulations 2000
    • Ionising Radiation (Medical Exposure) Regulations 2000. SI Health and Safety 2000 No. 1059.
    • SI Health and Safety 2000 No. 1059
  • 7
    • 2342439949 scopus 로고    scopus 로고
    • Radiation protection issues with the use of mini C-Arm image intensifiers in surgery in the upper limb: Optimisation of practice and the impact of new regulations
    • Sinha S, Evans S J, Arundell M K, Burke F D. Radiation protection issues with the use of mini C-Arm image intensifiers in surgery in the upper limb: Optimisation of practice and the impact of new regulations. J Bone Joint Surg (British Volume) 2004; 86: 333-336.
    • (2004) J Bone Joint Surg (British Volume) , vol.86 , pp. 333-336
    • Sinha, S.1    Evans, S.J.2    Arundell, M.K.3    Burke, F.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.