메뉴 건너뛰기




Volumn 20, Issue SUPPL. 2, 2005, Pages 75-78

The surgical management of femoral osteolysis

Author keywords

Femur osteolysis treatment; Total hip arthroplasty

Indexed keywords

ADULT; AGED; ALGORITHM; BONE GRAFT; BONE REGENERATION; CLINICAL ARTICLE; CONFERENCE PAPER; DEBRIDEMENT; FEMALE; FEMUR; FOLLOW UP; HIP SURGERY; HUMAN; MALE; OSTEOLYSIS; OUTCOMES RESEARCH; RADIOGRAPHY; REOPERATION; SATISFACTION; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS;

EID: 24944466899     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2005.03.019     Document Type: Conference Paper
Times cited : (8)

References (8)
  • 1
    • 0025126478 scopus 로고
    • Endosteal erosion in association with stable uncemented femoral components
    • W.J. Maloney, M. Jasty, and W.H. Harris Endosteal erosion in association with stable uncemented femoral components J Bone Joint Surg Am 72A 1990 1025
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 1025
    • Maloney, W.J.1    Jasty, M.2    Harris, W.H.3
  • 2
    • 0026718908 scopus 로고
    • The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement
    • M. Tanzer, W. Maloney, and J. Jasty The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement J Bone Joint Surg Am 74A 1992 404
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 404
    • Tanzer, M.1    Maloney, W.2    Jasty, J.3
  • 3
    • 0029818636 scopus 로고    scopus 로고
    • Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implant
    • Z. Wan, and L.D. Dorr Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implant J Arthroplasty 11 1996 718
    • (1996) J Arthroplasty , vol.11 , pp. 718
    • Wan, Z.1    Dorr, L.D.2
  • 4
    • 0030721981 scopus 로고    scopus 로고
    • Treatment of pelvic osteolysis associated with a stable acetabular component inserted without cement as part of a total hip replacement
    • W.J. Maloney, P. Herzwurm, and W. Paprosky Treatment of pelvic osteolysis associated with a stable acetabular component inserted without cement as part of a total hip replacement J Bone Joint Surg Am 79A 1997 628
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 628
    • Maloney, W.J.1    Herzwurm, P.2    Paprosky, W.3
  • 5
    • 0033659480 scopus 로고    scopus 로고
    • Particulate bone grafting of osteolytic femoral lesions around cementless stems
    • E. Benson, C. Christensen, and E. Monesmith Particulate bone grafting of osteolytic femoral lesions around cementless stems Clin Orthop 381 2000 58
    • (2000) Clin Orthop , vol.381 , pp. 58
    • Benson, E.1    Christensen, C.2    Monesmith, E.3
  • 6
    • 0036713083 scopus 로고    scopus 로고
    • Polyethylene liner exchange for excessive wear and osteolysis
    • K.M. Terefenko, C.J. Sychterz, and K. Orishimo Polyethylene liner exchange for excessive wear and osteolysis J Arthroplasty 17 2002 798
    • (2002) J Arthroplasty , vol.17 , pp. 798
    • Terefenko, K.M.1    Sychterz, C.J.2    Orishimo, K.3
  • 7
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • C.A. Engh, P. Massin, and K. Suthers Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components Clin Orthop 267 1990 107
    • (1990) Clin Orthop , vol.267 , pp. 107
    • Engh, C.A.1    Massin, P.2    Suthers, K.3
  • 8
    • 0018687995 scopus 로고
    • Modes of failure of cemented stem-type femoral components
    • T.A. Gruen, G.M. McNeice, and H.C. Amstutz Modes of failure of cemented stem-type femoral components Clin Orthop 141 1979 17
    • (1979) Clin Orthop , vol.141 , pp. 17
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.