메뉴 건너뛰기




Volumn 19, Issue 8, 2005, Pages 570-573

A technical note on percutaneous scaphoid fixation using a hybrid technique

Author keywords

fracture; percutaneous; Scaphoid; screw fixation hybrid technique

Indexed keywords

ADULT; ARTICLE; ARTICULAR CARTILAGE; BONE SCREW; FALLING; FEMALE; FLUOROSCOPY; FRACTURE HEALING; FRACTURE NONUNION; GRIP STRENGTH; GUIDE WIRE; HANDEDNESS; HUMAN; JOINT MOBILITY; MAJOR CLINICAL STUDY; MALE; OSTEOSYNTHESIS; POSTOPERATIVE COMPLICATION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; SCAPHOID FRACTURE; SPORT INJURY; SURGICAL TECHNIQUE; TRAFFIC ACCIDENT; TREATMENT CONTRAINDICATION; TREATMENT INDICATION; WORKMAN COMPENSATION; WRIST RADIOGRAPHY;

EID: 24944440881     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.bot.0000161538.39527.01     Document Type: Article
Times cited : (6)

References (21)
  • 1
    • 0034954088 scopus 로고    scopus 로고
    • Acutrak screw fixation versus cast immobilisation for undisplaced scaphoid waist fractures
    • Adolfsson L, Lindau T, Arner M. Acutrak screw fixation versus cast immobilisation for undisplaced scaphoid waist fractures. J Hand Surg [Br]. 2001;26:192-195.
    • (2001) J Hand Surg [Br] , vol.26 , pp. 192-195
    • Adolfsson, L.1    Lindau, T.2    Arner, M.3
  • 2
    • 0042315097 scopus 로고    scopus 로고
    • The results of treatment of 734 fresh, simple fractures of the scaphoid
    • Bohler L, Trojan E, Jahna H. The results of treatment of 734 fresh, simple fractures of the scaphoid. J Hand Surg [Br]. 2003;28:319-331.
    • (2003) J Hand Surg [Br] , vol.28 , pp. 319-331
    • Bohler, L.1    Trojan, E.2    Jahna, H.3
  • 3
    • 0035074908 scopus 로고    scopus 로고
    • Percutaneous screw fixation or cast immobilization for nondisplaced scaphoid fractures
    • Bond CD, Shin AY, McBride MT, et al. Percutaneous screw fixation or cast immobilization for nondisplaced scaphoid fractures. J Bone Joint Surg Am. 2001;83-A:483-488.
    • (2001) J Bone Joint Surg Am , vol.83 A , pp. 483-488
    • Bond, C.D.1    Shin, A.Y.2    McBride, M.T.3
  • 4
    • 0036906221 scopus 로고    scopus 로고
    • Percutaneous Herbert screw fixation for fractures of the scaphoid: Review of 30 cases
    • Brutus JP, Baeten Y, Chahidi N, et al. Percutaneous Herbert screw fixation for fractures of the scaphoid: review of 30 cases. Chir Main. 2002;21:350-354.
    • (2002) Chir Main , vol.21 , pp. 350-354
    • Brutus, J.P.1    Baeten, Y.2    Chahidi, N.3
  • 5
    • 0033803540 scopus 로고    scopus 로고
    • Percutaneous osteosynthesis of scaphoid fracture with the Herbert-Whipple screw-technique and results
    • Schadel-Hopfner M, BohringerG, Gotzen L. Percutaneous osteosynthesis of scaphoid fracture with the Herbert-Whipple screw-technique and results. Handchir Mikrochir Plast Chir. 2000;32:271-276.
    • (2000) Handchir Mikrochir Plast Chir , vol.32 , pp. 271-276
    • Schadel-Hopfner, M.1    Bohringer, G.2    Gotzen, L.3
  • 6
    • 0036905642 scopus 로고    scopus 로고
    • A simplified approach for unstable scaphoid fracture fixation using the Acutrak screw
    • Chung KC. A simplified approach for unstable scaphoid fracture fixation using the Acutrak screw. Plast Reconstr Surg. 2002;110:1697-1703.
    • (2002) Plast Reconstr Surg , vol.110 , pp. 1697-1703
    • Chung, K.C.1
  • 7
    • 0031984526 scopus 로고    scopus 로고
    • Acute percutaneous scaphoid fixation. A pilot study
    • Haddad FS, Goddard NJ. Acute percutaneous scaphoid fixation. A pilot study. J Hand Surg [Br]. 1998;80:95-99.
    • (1998) J Hand Surg [Br] , vol.80 , pp. 95-99
    • Haddad, F.S.1    Goddard, N.J.2
  • 8
    • 0035218379 scopus 로고    scopus 로고
    • Percutaneous fixation of scaphoid fractures
    • Slade JF, Jaskwhich D. Percutaneous fixation of scaphoid fractures. Hand Clin. 2001;17:553-574.
    • (2001) Hand Clin , vol.17 , pp. 553-574
    • Slade, J.F.1    Jaskwhich, D.2
  • 9
    • 0030467170 scopus 로고    scopus 로고
    • Nonunion of the scaphoid: Treatment with cannulated screws compared with treatment with Herbert screws
    • Trumble TE, Clarke T, Kreder HJ. Nonunion of the scaphoid: treatment with cannulated screws compared with treatment with Herbert screws. J Bone Joint Surg Am. 1996;78-A:1829-1837.
    • (1996) J Bone Joint Surg Am , vol.78 A , pp. 1829-1837
    • Trumble, T.E.1    Clarke, T.2    Kreder, H.J.3
  • 10
    • 0036982214 scopus 로고    scopus 로고
    • Primary fixation of displaced carpal scaphoid fractures with the Herbert-Whipple screw
    • Turkish
    • Bagatur AE, Zorer G. Primary fixation of displaced carpal scaphoid fractures with the Herbert-Whipple screw. Acta Orthop Traumatol Turc. 2002;36:341-345. Turkish.
    • (2002) Acta Orthop Traumatol Turc , vol.36 , pp. 341-345
    • Bagatur, A.E.1    Zorer, G.2
  • 11
    • 0036072207 scopus 로고    scopus 로고
    • Osteosynthesis for scaphoid fractures through a dorsal approach: One or two Herbert screws?
    • Gaujoux G. Osteosynthesis for scaphoid fractures through a dorsal approach: one or two Herbert screws? Chir Main. 2002;21:166-175.
    • (2002) Chir Main , vol.21 , pp. 166-175
    • Gaujoux, G.1
  • 12
    • 0021147614 scopus 로고
    • Management of the fractured scaphoid using a new bone screw
    • Herbert TJ, Fisher WE. Management of the fractured scaphoid using a new bone screw. J Bone Joint Surg. 1984;66B:114-123.
    • (1984) J Bone Joint Surg , vol.66 B , pp. 114-123
    • Herbert, T.J.1    Fisher, W.E.2
  • 14
    • 1642394813 scopus 로고    scopus 로고
    • Interfragmentary compression across a simulated scaphoid fracture-analysis of 3 screws
    • Beadel GP, Ferreira L, Johnson JA, et al. Interfragmentary compression across a simulated scaphoid fracture-analysis of 3 screws. J Hand Surg [Am]. 2004;29:273-278.
    • (2004) J Hand Surg [Am] , vol.29 , pp. 273-278
    • Beadel, G.P.1    Ferreira, L.2    Johnson, J.A.3
  • 15
    • 0742323071 scopus 로고    scopus 로고
    • Central screw placement in percutaneous screw scaphoid fixation: A cadaveric comparison of proximal and distal techniques
    • Chan KW, McAdams TR. Central screw placement in percutaneous screw scaphoid fixation: a cadaveric comparison of proximal and distal techniques. J Hand Surg [Am]. 2004;29:74-79.
    • (2004) J Hand Surg [Am] , vol.29 , pp. 74-79
    • Chan, K.W.1    McAdams, T.R.2
  • 16
    • 0346873925 scopus 로고    scopus 로고
    • Frequency and characteristics of the scaphoid cortical ring sign
    • Pirela-Cruz MA, Hilton ME, Faillace J. Frequency and characteristics of the scaphoid cortical ring sign. Surg Radial Anat. 2003;25:451-454.
    • (2003) Surg Radial Anat , vol.25 , pp. 451-454
    • Pirela-Cruz, M.A.1    Hilton, M.E.2    Faillace, J.3
  • 17
    • 0037986459 scopus 로고    scopus 로고
    • Acute percutaneous scaphoid fixation using a non-cannulated Herbert screw
    • De Vos J, Vandenberghe D. Acute percutaneous scaphoid fixation using a non-cannulated Herbert screw. Chir Main. 2003;22:78-83.
    • (2003) Chir Main , vol.22 , pp. 78-83
    • De Vos, J.1    Vandenberghe, D.2
  • 18
    • 0025297748 scopus 로고
    • Two modifications for insertion of the Herbert screw in the fractured scaphoid
    • Chun S, Wicks BP, Meyerdierks, et al. Two modifications for insertion of the Herbert screw in the fractured scaphoid. J Hand Surg [Am]. 1990;15: 669-671.
    • (1990) J Hand Surg [Am] , vol.15 , pp. 669-671
    • Chun, S.1    Wicks, B.P.2    Meyerdierks3
  • 19
    • 0023749739 scopus 로고
    • Carpal alignment after different surgical approaches to the scaphoid: A comparative study
    • Garcia E, Vall A, Salo JM, et al. Carpal alignment after different surgical approaches to the scaphoid: a comparative study. J Hand Surg [Am]. 1988;13:604-612.
    • (1988) J Hand Surg [Am] , vol.13 , pp. 604-612
    • Garcia, E.1    Vall, A.2    Salo, J.M.3
  • 20
    • 0024232058 scopus 로고
    • Technical factors to Herbert screw fixation
    • Adams BD, Blair WF, Reagan DS, et al. Technical factors to Herbert screw fixation. J Hand Surg [Am]. 1988;13:893-899.
    • (1988) J Hand Surg [Am] , vol.13 , pp. 893-899
    • Adams, B.D.1    Blair, W.F.2    Reagan, D.S.3
  • 21
    • 0024522483 scopus 로고
    • Comparison of short and long thumb-spica casts for non-displaced fractures of the carpal scaphoid
    • Gellman H, Caputo RJ, Carter V, et al. Comparison of short and long thumb-spica casts for non-displaced fractures of the carpal scaphoid. J Bone Joint Surg Am. 1989;71:354-357.
    • (1989) J Bone Joint Surg Am , vol.71 , pp. 354-357
    • Gellman, H.1    Caputo, R.J.2    Carter, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.