메뉴 건너뛰기




Volumn 45, Issue 8, 2005, Pages 395-398

Quantitative analysis of magnetic resonance imaging susceptibility artifacts caused by neurosurgical biomaterials: Comparison of 0.5, 1.5, and 3.0 Tesla magnetic fields

Author keywords

Ceramic; Magnetic field strength; Magnetic resonance imaging; Neurosurgical implants

Indexed keywords

BIOMATERIAL; COBALT; TITANIUM;

EID: 24744471226     PISSN: 04708105     EISSN: None     Source Type: Journal    
DOI: 10.2176/nmc.45.395     Document Type: Article
Times cited : (47)

References (17)
  • 1
    • 0025968812 scopus 로고
    • Surgical decompressive procedures for cervical spondylotic myelopathy. A study using magnetic resonance imaging
    • Batzdorf U, Flannigan BD: Surgical decompressive procedures for cervical spondylotic myelopathy. A study using magnetic resonance imaging. Spine 16: 123-127, 1991
    • (1991) Spine , vol.16 , pp. 123-127
    • Batzdorf, U.1    Flannigan, B.D.2
  • 6
  • 7
  • 8
    • 0032862344 scopus 로고    scopus 로고
    • Artefact on MRA following aneurysm clipping: An in vitro study and prospective comparison with conventional angiography
    • Grieve JP, Stacey R, Moore E, Kitchen ND, Jager HR: Artefact on MRA following aneurysm clipping: an in vitro study and prospective comparison with conventional angiography. Neuroradiology 41: 680-686, 1999
    • (1999) Neuroradiology , vol.41 , pp. 680-686
    • Grieve, J.P.1    Stacey, R.2    Moore, E.3    Kitchen, N.D.4    Jager, H.R.5
  • 9
    • 0019472338 scopus 로고
    • Reconstruction of the sellar floor during transsphenoidal operations using alumina ceramic
    • Kobayashi S, Sugita K, Matsuo K, Inoue T: Reconstruction of the sellar floor during transsphenoidal operations using alumina ceramic. Surg Neurol 15: 196-197, 1981
    • (1981) Surg Neurol , vol.15 , pp. 196-197
    • Kobayashi, S.1    Sugita, K.2    Matsuo, K.3    Inoue, T.4
  • 10
    • 0022628015 scopus 로고
    • Porous hydroxyapatite ceramics for use in neurosurgical practice
    • Koyama T, Handa J: Porous hydroxyapatite ceramics for use in neurosurgical practice. Surg Neurol 25: 71-73, 1986
    • (1986) Surg Neurol , vol.25 , pp. 71-73
    • Koyama, T.1    Handa, J.2
  • 11
    • 0036895834 scopus 로고    scopus 로고
    • Quantification of susceptibility artifacts produced on high-field magnetic resonance images by various biomaterials used for neurosurgical implants. Technical note
    • Matsuura H, Inoue T, Konno H, Sasaki M, Ogasawara K, Ogawa A: Quantification of susceptibility artifacts produced on high-field magnetic resonance images by various biomaterials used for neurosurgical implants. Technical note. J Neurosurg 97: 1472-1475, 2002
    • (2002) J Neurosurg , vol.97 , pp. 1472-1475
    • Matsuura, H.1    Inoue, T.2    Konno, H.3    Sasaki, M.4    Ogasawara, K.5    Ogawa, A.6
  • 12
    • 0032867535 scopus 로고    scopus 로고
    • MRI artifacts of metallic stents derived from imaging sequencing and the ferromagnetic nature of materials
    • Nitatori T, Hanaoka H, Hachiya J, Yokoyama K: MRI artifacts of metallic stents derived from imaging sequencing and the ferromagnetic nature of materials. Radiat Med 17: 329-334, 1999
    • (1999) Radiat Med , vol.17 , pp. 329-334
    • Nitatori, T.1    Hanaoka, H.2    Hachiya, J.3    Yokoyama, K.4
  • 13
    • 0034465612 scopus 로고    scopus 로고
    • Quantification and minimization of magnetic susceptibility artifacts on GRE images
    • Port JD, Pomper MG: Quantification and minimization of magnetic susceptibility artifacts on GRE images. J Comput Assist Tomogr 24: 958-964, 2000
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 958-964
    • Port, J.D.1    Pomper, M.G.2
  • 14
    • 0030276972 scopus 로고    scopus 로고
    • Ceramic surgical instruments: Ex vivo evaluation of compatibility with MR imaging at 1.5 T
    • Shellock FG, Shellock VJ: Ceramic surgical instruments: ex vivo evaluation of compatibility with MR imaging at 1.5 T. J Magn Reson Imaging 6: 954-956, 1996
    • (1996) J Magn Reson Imaging , vol.6 , pp. 954-956
    • Shellock, F.G.1    Shellock, V.J.2
  • 15
    • 0031884231 scopus 로고    scopus 로고
    • Spetzler titanium aneurysm clips: Compatibility at MR imaging
    • Shellock FG, Shellock VJ: Spetzler titanium aneurysm clips: compatibility at MR imaging. Radiology 206: 838-841, 1998
    • (1998) Radiology , vol.206 , pp. 838-841
    • Shellock, F.G.1    Shellock, V.J.2
  • 16
    • 0028900149 scopus 로고
    • Magnetic resonance imaging of titanium anterior cervical spine plating systems
    • Tominaga T, Shimizu H, Koshu K, Kayama T, Yoshimoto T: Magnetic resonance imaging of titanium anterior cervical spine plating systems. Neurosurgery 36: 951-955, 1995
    • (1995) Neurosurgery , vol.36 , pp. 951-955
    • Tominaga, T.1    Shimizu, H.2    Koshu, K.3    Kayama, T.4    Yoshimoto, T.5
  • 17
    • 0023857438 scopus 로고
    • Reconstruction of surgical skull defects with hydroxylapatite ceramic buttons and granules
    • Yamashima T: Reconstruction of surgical skull defects with hydroxylapatite ceramic buttons and granules. Acta Neurochir (Wien) 90: 157-162, 1988
    • (1988) Acta Neurochir (Wien) , vol.90 , pp. 157-162
    • Yamashima, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.