메뉴 건너뛰기




Volumn 53, Issue 3, 2005, Pages 146-149

Monitoring the European standard series in 10 centres 1996-2000

Author keywords

Clinical epidemiology; European standard series; Patch test reactions; Sensitization frequencies

Indexed keywords

4 HYDROXYBENZOIC ACID ESTER; ALLERGEN; BENZOCAINE; BUDESONIDE; CLIOQUINOL; COBALT CHLORIDE; DICHROMATE POTASSIUM; DISULFIRAM; EPOXY RESIN; FORMALDEHYDE; FRAGRANCE; ISOTHIAZOLE DERIVATIVE; LANOLIN; MERCAPTOBENZOTHIAZOLE; NEOMYCIN; NICKEL SULFATE; QUATERNIUM 15; ROSIN; SESQUITERPENE LACTONE; THIOL DERIVATIVE; TIXOCORTOL;

EID: 24744460504     PISSN: 01051873     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.0105-1873.2005.00541.x     Document Type: Article
Times cited : (79)

References (13)
  • 3
    • 0034125826 scopus 로고    scopus 로고
    • Recommendation to include budesonide and tixocortol pivalate in the European standard series
    • Isakson M, Brandão F M, Bruze M, Goossens A. Recommendation to include budesonide and tixocortol pivalate in the European standard series. Contact Dermatitis 2000: 43: 41-42.
    • (2000) Contact Dermatitis , vol.43 , pp. 41-42
    • Isakson, M.1    Brandão, F.M.2    Bruze, M.3    Goossens, A.4
  • 4
    • 0036318486 scopus 로고    scopus 로고
    • Monitoring levels of preservative sensitivity in Europe. A 10-year overview (1991-2000)
    • Wilkinson J D, Shaw S, Andersen K E, et al. Monitoring levels of preservative sensitivity in Europe. A 10-year overview (1991-2000). Contact Dermatitis 2002: 46: 207-210.
    • (2002) Contact Dermatitis , vol.46 , pp. 207-210
    • Wilkinson, J.D.1    Shaw, S.2    Andersen, K.E.3
  • 5
    • 0031966347 scopus 로고    scopus 로고
    • Multicentre patch test studies: Are they worth the effort?
    • Andersen K E. Multicentre patch test studies: are they worth the effort? Contact Dermatitis 1998: 38: 222-223.
    • (1998) Contact Dermatitis , vol.38 , pp. 222-223
    • Andersen, K.E.1
  • 8
    • 17844382125 scopus 로고    scopus 로고
    • Patch testing disconcordance alert: False-negative findings with rubber additives and fragrances
    • Sherertz E F, Fransway A F, Belisto D V, et al. Patch testing disconcordance alert: false-negative findings with rubber additives and fragrances. J Am Acad Dermatol 2001: 45: 313-314.
    • (2001) J Am Acad Dermatol , vol.45 , pp. 313-314
    • Sherertz, E.F.1    Fransway, A.F.2    Belisto, D.V.3
  • 11
    • 0030902325 scopus 로고    scopus 로고
    • Proposal for a revised international standard series of patch tests
    • Lachapelle J-M, Ale S I, Freeman S, et al. Proposal for a revised international standard series of patch tests. Contact Dermatitis 1997: 36: 212-213.
    • (1997) Contact Dermatitis , vol.36 , pp. 212-213
    • Lachapelle, J.-M.1    Ale, S.I.2    Freeman, S.3
  • 12
    • 0036235821 scopus 로고    scopus 로고
    • Decrease in nickel sensitisation in a Danish schoolgirl population with ears pierced after implementation of a nickel-exposure regulation
    • Jensen C S, Lisby S, Baadsgaard O, Vølund A, Menneø T. Decrease in nickel sensitisation in a Danish schoolgirl population with ears pierced after implementation of a nickel-exposure regulation. Br J Dermatol 2002: 146: 636-642.
    • (2002) Br J Dermatol , vol.146 , pp. 636-642
    • Jensen, C.S.1    Lisby, S.2    Baadsgaard, O.3    Vølund, A.4    Menneø, T.5
  • 13
    • 0346725882 scopus 로고    scopus 로고
    • Occupational skin disease in the construction industry
    • Bock M, Schmidt A, Bruckner T, Diepgen T L. Occupational skin disease in the construction industry. Br J Dermatol 2003: 149: 43-50.
    • (2003) Br J Dermatol , vol.149 , pp. 43-50
    • Bock, M.1    Schmidt, A.2    Bruckner, T.3    Diepgen, T.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.