메뉴 건너뛰기




Volumn 22, Issue 3, 2005, Pages 427-432

Evaluation of the RF field uniformity of a double-tuned 31P/1H birdcage RF coil for spin-echo MRI/MRS of the diabetic foot

Author keywords

3 Tesla; Birdcage coil; Diabetes; Non proton MRI; RARE imaging

Indexed keywords

ACCURACY; ARTICLE; CONCENTRATION RESPONSE; CONTROLLED STUDY; DIABETIC FOOT; DIABETIC NEUROPATHY; FOREFOOT; HUMAN; HUMAN CELL; HUMAN TISSUE; IMAGE ENHANCEMENT; METATARSAL BONE; MUSCLE CELL; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; PRIORITY JOURNAL; STANDARD;

EID: 24744455898     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20372     Document Type: Article
Times cited : (21)

References (20)
  • 1
    • 0025341602 scopus 로고
    • Relationship of endoneurial capillary abnormalities to type and severity of diabetic polyneuropathy
    • Britland S, Young R, Sharma A, et al. Relationship of endoneurial capillary abnormalities to type and severity of diabetic polyneuropathy. Diabetes 1990;39:909-913.
    • (1990) Diabetes , vol.39 , pp. 909-913
    • Britland, S.1    Young, R.2    Sharma, A.3
  • 2
    • 0036673529 scopus 로고    scopus 로고
    • Intrinsic muscle atrophy and toe deformity in the diabetic neuropathic foot: A magnetic resonance imaging study
    • Bus SA, Yang QX, Wang JH, et al. Intrinsic muscle atrophy and toe deformity in the diabetic neuropathic foot: a magnetic resonance imaging study. Diabetes Care 2002;25:1444-1450.
    • (2002) Diabetes Care , vol.25 , pp. 1444-1450
    • Bus, S.A.1    Yang, Q.X.2    Wang, J.H.3
  • 3
    • 0033624963 scopus 로고    scopus 로고
    • 1H and 31P-magnetic resonance spectroscopy and imaging as a new diagnostic tool to evaluate neuropathic foot ulcers in type II diabetes
    • Suzuki E, Kashiwag A, Hidaka H, et al. 1H and 31P-magnetic resonance spectroscopy and imaging as a new diagnostic tool to evaluate neuropathic foot ulcers in type II diabetes. Diabetologia 2000;43:165-172.
    • (2000) Diabetologia , vol.43 , pp. 165-172
    • Suzuki, E.1    Kashiwag, A.2    Hidaka, H.3
  • 4
    • 0031958194 scopus 로고    scopus 로고
    • Fast imaging of phosphocreatine using a RARE pulse sequence
    • Greenman RL, Elliott MA, Vandenborne K, et al. Fast imaging of phosphocreatine using a RARE pulse sequence. Magn Reson Med 1998;39:851-854.
    • (1998) Magn Reson Med , vol.39 , pp. 851-854
    • Greenman, R.L.1    Elliott, M.A.2    Vandenborne, K.3
  • 5
    • 0036196438 scopus 로고    scopus 로고
    • Fast imaging of phosphocreatine in the normal human myocardium using a three-dimensional RARE pulse sequence at 4 Tesla
    • Greenman RL, Axel L, Ferrari V, et al. Fast imaging of phosphocreatine in the normal human myocardium using a three-dimensional RARE pulse sequence at 4 Tesla. J Magn Reson Imaging 2002;15: 467-472.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 467-472
    • Greenman, R.L.1    Axel, L.2    Ferrari, V.3
  • 6
    • 0028290898 scopus 로고
    • Short TE phosphorus spectroscopy using a spin-echo pulse
    • Lim K, Pauly J, Webb P, et al. Short TE phosphorus spectroscopy using a spin-echo pulse. Magn Reson Med 1994;32:98-103.
    • (1994) Magn Reson Med , vol.32 , pp. 98-103
    • Lim, K.1    Pauly, J.2    Webb, P.3
  • 8
    • 0030265261 scopus 로고    scopus 로고
    • Effect of profound ischaemia on human muscle: MRI, phosphorus MRS and near-infrared studies
    • Hajnal JV, Roberts I, Wilson J, et al. Effect of profound ischaemia on human muscle: MRI, phosphorus MRS and near-infrared studies. NMR Biomed 1996;9:305-314.
    • (1996) NMR Biomed , vol.9 , pp. 305-314
    • Hajnal, J.V.1    Roberts, I.2    Wilson, J.3
  • 9
    • 7544241633 scopus 로고    scopus 로고
    • Quantification of the 31P metabolite concentration in human skeletal muscle from RARE signal intensity
    • Greenman RL. Quantification of the 31P metabolite concentration in human skeletal muscle from RARE signal intensity. Magn Reson Med 2004;52:1036-1042.
    • (2004) Magn Reson Med , vol.52 , pp. 1036-1042
    • Greenman, R.L.1
  • 10
    • 0038050726 scopus 로고    scopus 로고
    • Double inversion black-blood fast spin-echo imaging of the human heart: A comparison between 1.5T and 3.0T
    • Greenman RL, Shlrosky J, Mulkern R, et al. Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5T and 3.0T. J Magn Reson Imaging 2003;17:648-655.
    • (2003) J Magn Reson Imaging , vol.17 , pp. 648-655
    • Greenman, R.L.1    Shlrosky, J.2    Mulkern, R.3
  • 11
    • 0033051407 scopus 로고    scopus 로고
    • Magnetic resonance imaging techniques demonstrate soft tissue damage in the diabetic foot
    • Brash P, Fostert J, Vennart W, et al. Magnetic resonance imaging techniques demonstrate soft tissue damage in the diabetic foot. Diabet Med 1999;16:55-61.
    • (1999) Diabet Med , vol.16 , pp. 55-61
    • Brash, P.1    Fostert, J.2    Vennart, W.3
  • 12
    • 0031879106 scopus 로고    scopus 로고
    • Evaluation of the effects of high dose irradiation on canine thigh muscle by follow-up magnetic resonance imaging and phosphorus-31 magnetic resonance spectroscopy
    • Choe B-Y, Jee W-H, Suh T-S, et al. Evaluation of the effects of high dose irradiation on canine thigh muscle by follow-up magnetic resonance imaging and phosphorus-31 magnetic resonance spectroscopy. Invest Radiol 1998;35:300-307.
    • (1998) Invest Radiol , vol.35 , pp. 300-307
    • Choe, B.-Y.1    Jee, W.-H.2    Suh, T.-S.3
  • 13
    • 1542286626 scopus 로고    scopus 로고
    • Novel RF coil geometry for lower extremity imaging
    • Brown R, Mareyam A, Reid E, et al. Novel RF coil geometry for lower extremity imaging. Magn Reson Med 2004;51:635-639.
    • (2004) Magn Reson Med , vol.51 , pp. 635-639
    • Brown, R.1    Mareyam, A.2    Reid, E.3
  • 14
    • 0032839547 scopus 로고    scopus 로고
    • Application of a birdcage coil at 3 Tesla to imaging of the human knee using MRI
    • Peterson D, Carruthers C, Wolverton K, et al. Application of a birdcage coil at 3 Tesla to imaging of the human knee using MRI. Magn Reson Med 1999;43:215-221.
    • (1999) Magn Reson Med , vol.43 , pp. 215-221
    • Peterson, D.1    Carruthers, C.2    Wolverton, K.3
  • 15
    • 38249017194 scopus 로고
    • A design for a double-tuned birdcage coil for use in an integrated MRI/MRS examination
    • Isaac G, Schnall M, Lenkinski R, et al. A design for a double-tuned birdcage coil for use in an integrated MRI/MRS examination. J Magn Reson 1990;89:41-50.
    • (1990) J Magn Reson , vol.89 , pp. 41-50
    • Isaac, G.1    Schnall, M.2    Lenkinski, R.3
  • 16
    • 0037965623 scopus 로고
    • B1 insensitive adiabatic RF pulses
    • Bronskill M, Sprawls P. editors. Woodbury, NY: American Institute of Physics, Inc.
    • Garwood M, Ugurbil K. B1 insensitive adiabatic RF pulses. In: Bronskill M, Sprawls P. editors. The Physics of MRI-1992 AAPM Summer School Proceedings. Woodbury, NY: American Institute of Physics, Inc.: 1993. p 110-147.
    • (1993) The Physics of MRI-1992 AAPM Summer School Proceedings , pp. 110-147
    • Garwood, M.1    Ugurbil, K.2
  • 17
    • 0032129166 scopus 로고    scopus 로고
    • Standing-wave and RF penetration artifacts caused by elliptical geometry: An electrodynamic analysis of MRI
    • Sled J, Pike B. Standing-wave and RF penetration artifacts caused by elliptical geometry: an electrodynamic analysis of MRI. IEEE Trans Med Imaging 1998;17:653-662.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 653-662
    • Sled, J.1    Pike, B.2
  • 18
    • 0032769515 scopus 로고    scopus 로고
    • A practical double-tuned 1H/31P quadrature birdcage headcoil optimized for 31P operation
    • Matson G, Vermathen P, Hill T. A practical double-tuned 1H/31P quadrature birdcage headcoil optimized for 31P operation. Magn Reson Med 1999;42:173-182.
    • (1999) Magn Reson Med , vol.42 , pp. 173-182
    • Matson, G.1    Vermathen, P.2    Hill, T.3
  • 19
    • 0028380011 scopus 로고
    • Two configurations of the four-ring birdcage coil for 1H imaging and 1H-decoupled 31P spectroscopy of the human head
    • Murphy-Boesch J, Srinivasan R, Carvajal L, et al. Two configurations of the four-ring birdcage coil for 1H imaging and 1H-decoupled 31P spectroscopy of the human head. J Magn Reson B 1994;103:103-114.
    • (1994) J Magn Reson B , vol.103 , pp. 103-114
    • Murphy-Boesch, J.1    Srinivasan, R.2    Carvajal, L.3
  • 20
    • 0002931369 scopus 로고
    • Mapping of the radio frequency field
    • Insko E, Bolinger L. Mapping of the radio frequency field. J Magn Reson 1993;103:82-85.
    • (1993) J Magn Reson , vol.103 , pp. 82-85
    • Insko, E.1    Bolinger, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.