메뉴 건너뛰기




Volumn 26, Issue 3-4, 2005, Pages 318-323

Dry and moist heat sterilisation cannot inactivate pyrogenicity of Gram positive microorganisms

Author keywords

B. subtilis endospores; Dry heat; Interleukin 6; Moist heat; Mono Mac 6; Pyrogen; S. aureus

Indexed keywords

INTERLEUKIN 6; PYROGEN;

EID: 24644476537     PISSN: 09280987     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejps.2005.07.003     Document Type: Article
Times cited : (20)

References (16)
  • 1
    • 0029964464 scopus 로고    scopus 로고
    • Effect of steam-heat treatment with/without divalent cations on the inactivation of lipopolysaccharides from several bacterial species
    • T. Bamba, R. Matsui, and K. Watabe Effect of steam-heat treatment with/without divalent cations on the inactivation of lipopolysaccharides from several bacterial species PDA J. Pharm. Sci. Technol. 50 1996 129 135
    • (1996) PDA J. Pharm. Sci. Technol. , vol.50 , pp. 129-135
    • Bamba, T.1    Matsui, R.2    Watabe, K.3
  • 2
    • 0030583226 scopus 로고    scopus 로고
    • The use of human monocytoid lines as indicators of endotoxin
    • S. Eperon, and T.W. Jungi The use of human monocytoid lines as indicators of endotoxin J. Immunol. Methods 194 1996 121 129
    • (1996) J. Immunol. Methods , vol.194 , pp. 121-129
    • Eperon, S.1    Jungi, T.W.2
  • 3
    • 0036327781 scopus 로고    scopus 로고
    • Wet heat inactivation of lipopolysaccharide from E. coli serotype 055:B5
    • S. Fujii, M. Takai, and T. Maki Wet heat inactivation of lipopolysaccharide from E. coli serotype 055:B5 PDA J. Pharm. Sci. Technol. 56 2002 220 227
    • (2002) PDA J. Pharm. Sci. Technol. , vol.56 , pp. 220-227
    • Fujii, S.1    Takai, M.2    Maki, T.3
  • 4
    • 0027991185 scopus 로고
    • Validation of dry heat inactivation of bacterial endotoxins
    • W. Hecker, D. Witthauer, and A. Staerk Validation of dry heat inactivation of bacterial endotoxins PDA J. Pharm. Sci. Technol. 48 1994 197 204
    • (1994) PDA J. Pharm. Sci. Technol. , vol.48 , pp. 197-204
    • Hecker, W.1    Witthauer, D.2    Staerk, A.3
  • 6
    • 0025343614 scopus 로고
    • Dry heat inactivation of endotoxin on the surface of glass
    • J.D. Ludwig, and K.E. Avis Dry heat inactivation of endotoxin on the surface of glass J. Parenter. Sci. Technol. 44 1990 4 12
    • (1990) J. Parenter. Sci. Technol. , vol.44 , pp. 4-12
    • Ludwig, J.D.1    Avis, K.E.2
  • 7
    • 0034083854 scopus 로고    scopus 로고
    • Ultrasonication of pyrogenic microorganisms improves the detection of pyrogens in the Mono Mac 6 assay
    • L. Moesby, E.W. Hansen, and J.D. Christensen Ultrasonication of pyrogenic microorganisms improves the detection of pyrogens in the Mono Mac 6 assay Eur. J. Pharm. Sci. 11 2000 51 57
    • (2000) Eur. J. Pharm. Sci. , vol.11 , pp. 51-57
    • Moesby, L.1    Hansen, E.W.2    Christensen, J.D.3
  • 8
    • 0041667796 scopus 로고    scopus 로고
    • Endospores of B. subtilis are pyrogenic and activate Mono Mac 6 cells: Importance of the CD14 receptor
    • L. Moesby, E.W. Hansen, J.D. Christensen, L. Tommerup, and C. Nielsen Endospores of B. subtilis are pyrogenic and activate Mono Mac 6 cells: importance of the CD14 receptor Eur. J. Pharm. Sci. 19 2003 245 251
    • (2003) Eur. J. Pharm. Sci. , vol.19 , pp. 245-251
    • Moesby, L.1    Hansen, E.W.2    Christensen, J.D.3    Tommerup, L.4    Nielsen, C.5
  • 9
    • 0032702312 scopus 로고    scopus 로고
    • A comparative study of Mono Mac 6 cells, isolated mononuclear cells and Limulus amoebocyte lysate assay in pyrogen testing
    • L. Moesby, S. Jensen, E.W. Hansen, and J.D. Christensen A comparative study of Mono Mac 6 cells, isolated mononuclear cells and Limulus amoebocyte lysate assay in pyrogen testing Int. J. Pharm. 191 1999 141 149
    • (1999) Int. J. Pharm. , vol.191 , pp. 141-149
    • Moesby, L.1    Jensen, S.2    Hansen, E.W.3    Christensen, J.D.4
  • 10
    • 0027525586 scopus 로고
    • Destruction of typical endotoxins by dry heat as determined using LAL assay and pyrogen assay
    • T. Nakata Destruction of typical endotoxins by dry heat as determined using LAL assay and pyrogen assay J. Parenter. Sci. Technol. 47 1993 258 264
    • (1993) J. Parenter. Sci. Technol. , vol.47 , pp. 258-264
    • Nakata, T.1
  • 11
    • 0028349638 scopus 로고
    • Destruction of challenged endotoxin in a dry heat oven
    • T. Nakata Destruction of challenged endotoxin in a dry heat oven J. Pharm. Sci. Technol. 48 1994 59 63
    • (1994) J. Pharm. Sci. Technol. , vol.48 , pp. 59-63
    • Nakata, T.1
  • 12
    • 0024419515 scopus 로고
    • Inactivation of B. subtilis spores and E. coli endotoxin by ethylene oxide
    • M.R. Pedersen, and E.W. Hansen Inactivation of B. subtilis spores and E. coli endotoxin by ethylene oxide J. Clin. Pharm. Ther. 14 1989 373 380
    • (1989) J. Clin. Pharm. Ther. , vol.14 , pp. 373-380
    • Pedersen, M.R.1    Hansen, E.W.2
  • 13
    • 0028025603 scopus 로고
    • Detection of lipopolysaccharide in the picogram range of tissue culture media by a kinetic chromogenic Limulus amebocyte lysate assay
    • M.R. Pedersen, E.W. Hansen, and J.D. Christensen Detection of lipopolysaccharide in the picogram range of tissue culture media by a kinetic chromogenic Limulus amebocyte lysate assay J. Clin. Pharm. Ther. 19 1994 189 194
    • (1994) J. Clin. Pharm. Ther. , vol.19 , pp. 189-194
    • Pedersen, M.R.1    Hansen, E.W.2    Christensen, J.D.3
  • 15
    • 0018166195 scopus 로고
    • Dry-heat destruction of lipopolysaccharide: Mathematical approach to process evaluation
    • K. Tsuji, and A.R. Lewis Dry-heat destruction of lipopolysaccharide: mathematical approach to process evaluation Appl. Environ. Microbiol. 36 1978 715 719
    • (1978) Appl. Environ. Microbiol. , vol.36 , pp. 715-719
    • Tsuji, K.1    Lewis, A.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.