메뉴 건너뛰기




Volumn 152, Issue 1-3, 2005, Pages 37-40

DNA sensor based on functionalized polypyrrole

Author keywords

AC impedance; Cyclic volammetry; DNA sensor; Polypyrrole derivative

Indexed keywords

CHARGE TRANSFER; CYCLIC VOLTAMMETRY; DNA; ELECTRIC IMPEDANCE; ELECTRIC RESISTANCE; ELECTROPOLYMERIZATION; GRAFTING (CHEMICAL); POLYPROPYLENES;

EID: 24644470159     PISSN: 03796779     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.synthmet.2005.07.103     Document Type: Conference Paper
Times cited : (23)

References (9)
  • 2
    • 0013051355 scopus 로고    scopus 로고
    • DNA arrays: Methods and protocols
    • Totowa, NJ: Humana Press
    • DNA arrays: methods and protocols. Methods in molecular biology, (Ed.), J.B. Rampal. 2001: Totowa, NJ: Humana Press
    • (2001) Methods in Molecular Biology
    • Rampal, J.B.1
  • 3
    • 0034529546 scopus 로고    scopus 로고
    • Biosensors based on immobilization of biomolecules by electrogenerated polymer films new perspectives
    • S. Cosnier Biosensors based on immobilization of biomolecules by electrogenerated polymer films new perspectives Appl. Biochem. Biotech. 89 2-3 2000 127 138
    • (2000) Appl. Biochem. Biotech. , vol.89 , Issue.2-3 , pp. 127-138
    • Cosnier, S.1
  • 4
    • 0036061659 scopus 로고    scopus 로고
    • Charge storage in conducting polymers: Solitons, polarons, and bipolarons
    • A.J. Heeger Charge storage in conducting polymers: Solitons, polarons, and bipolarons Polymer J. 34 5-2 2002 148 155
    • (2002) Polymer J. , vol.34 , Issue.2-5 , pp. 148-155
    • Heeger, A.J.1
  • 5
    • 0032669794 scopus 로고    scopus 로고
    • Toward intelligent polymers: DNA sensors based on oligonucleotide-functionalized polypyrroles
    • F. Garnier, H. Korri-Youssoufi, P. Srivastava, B. Mindrand, and T. Dclair Toward intelligent polymers: DNA sensors based on oligonucleotide-functionalized polypyrroles Synth. Met. 100 1999 89 94
    • (1999) Synth. Met. , vol.100 , pp. 89-94
    • Garnier, F.1    Korri-Youssoufi, H.2    Srivastava, P.3    Mindrand, B.4    Dclair, T.5
  • 6
    • 0035838839 scopus 로고    scopus 로고
    • Electronically conductive polymer grafted with oligonucleotides as electrosensors of DNA. Preliminary study of real time monitoring by in situ techniques
    • N. Lassalle, P. Mailley, E. Vieil, T. Livache, A. Roget, J.P. Cotreia, and L.M. Abrantes Electronically conductive polymer grafted with oligonucleotides as electrosensors of DNA. Preliminary study of real time monitoring by in situ techniques J. Electroanal. Chem. 509 2001 48 57
    • (2001) J. Electroanal. Chem. , vol.509 , pp. 48-57
    • Lassalle, N.1    Mailley, P.2    Vieil, E.3    Livache, T.4    Roget, A.5    Cotreia, J.P.6    Abrantes, L.M.7
  • 7
    • 0035891257 scopus 로고    scopus 로고
    • Direct DNA hybridization detection based on the oligonucleotide-functionalized conductive polymer
    • T.-Y. Lee, and Y.-B. Shim Direct DNA hybridization detection based on the oligonucleotide-functionalized conductive polymer Anal. Chem. 73 2001 5629 5632
    • (2001) Anal. Chem. , vol.73 , pp. 5629-5632
    • Lee, T.-Y.1    Shim, Y.-B.2
  • 9
    • 0035952341 scopus 로고    scopus 로고
    • Optimizing the immobilization of single-stranded DNA onto glass beads
    • M.K. Walsh, X. Wang, and B.C. Weimer Optimizing the immobilization of single-stranded DNA onto glass beads J. Biochem. Biophys. Methods 47 2001 221 223
    • (2001) J. Biochem. Biophys. Methods , vol.47 , pp. 221-223
    • Walsh, M.K.1    Wang, X.2    Weimer, B.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.