메뉴 건너뛰기




Volumn 4, Issue 4, 2005, Pages 332-340

Is the Allen's test adequate to safely confirm that a radial artery may be harvested for coronary arterial bypass grafting?

Author keywords

Allen's test; Radial artery

Indexed keywords

ALLEN TEST; ARM BLOOD FLOW; ARTERY BLOOD FLOW; ARTERY GRAFT; ARTERY OCCLUSION; ARTICLE; BLOOD PRESSURE; COLLATERAL CIRCULATION; CORONARY ARTERY BYPASS GRAFT; DOPPLER FLOWMETRY; FUNCTION TEST; HUMAN; INTERMETHOD COMPARISON; NEUROLOGICAL COMPLICATION; NUCLEAR MAGNETIC RESONANCE IMAGING; PLETHYSMOGRAPHY; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RADIAL ARTERY; VASCULAR DISEASE;

EID: 24644463687     PISSN: 15699293     EISSN: None     Source Type: Journal    
DOI: 10.1510/icvts.2005.110247     Document Type: Article
Times cited : (21)

References (16)
  • 2
    • 0024404207 scopus 로고
    • Assessing collateral circulation in the hand - Four methods compared
    • Glavin RJ, Jones HM. Assessing collateral circulation in the hand - four methods compared. Anaesthesia 1989;44:594-595.
    • (1989) Anaesthesia , vol.44 , pp. 594-595
    • Glavin, R.J.1    Jones, H.M.2
  • 4
    • 0033791852 scopus 로고    scopus 로고
    • Reliability of Allen's test in selection of patients for radial artery harvest
    • Jarvis MA, Jarvis CL, Jones PR, Spyt TJ. Reliability of Allen's test in selection of patients for radial artery harvest. Ann Thorac Surg 2000;70:1362-1365.
    • (2000) Ann Thorac Surg , vol.70 , pp. 1362-1365
    • Jarvis, M.A.1    Jarvis, C.L.2    Jones, P.R.3    Spyt, T.J.4
  • 5
    • 0036301891 scopus 로고    scopus 로고
    • Is Allen's test not reliable in the selection of patients for radial artery harvest
    • Sajja LR, Mannam G, Sompalli S. Is Allen's test not reliable in the selection of patients for radial artery harvest (letter)? Ann Thorac Surg 2002;74:296.
    • (2002) Ann Thorac Surg , vol.74 , pp. 296
    • Sajja, L.R.1    Mannam, G.2    Sompalli, S.3
  • 6
    • 0035069596 scopus 로고    scopus 로고
    • Preoperative assessment of hand circulation by means of Doppler ultrasonography and the modified Allen test
    • Ruengsakulrach P, Brooks M, Hare DL, Gordon I, Buxton BF. Preoperative assessment of hand circulation by means of Doppler ultrasonography and the modified Allen test. J Thorac & Cardiovasc Surg 2001;121:526-531.
    • (2001) J Thorac & Cardiovasc Surg , vol.121 , pp. 526-531
    • Ruengsakulrach, P.1    Brooks, M.2    Hare, D.L.3    Gordon, I.4    Buxton, B.F.5
  • 9
    • 1642441585 scopus 로고    scopus 로고
    • Duplex ultrasonography predicts safety of radial artery harvest in the presence of an abnormal Allen test
    • Abu-Omar Y, Mussa S, Anastasiadis K, Steel S, Hands L, Taggart DP. Duplex ultrasonography predicts safety of radial artery harvest in the presence of an abnormal Allen test. Ann Thorac Surg 2000;77:116-119.
    • (2000) Ann Thorac Surg , vol.77 , pp. 116-119
    • Abu-Omar, Y.1    Mussa, S.2    Anastasiadis, K.3    Steel, S.4    Hands, L.5    Taggart, D.P.6
  • 10
    • 0035168452 scopus 로고    scopus 로고
    • Functional status of the hand after radial artery harvesting: Results in 3977 cases
    • Meharwal ZS, Trehan N. Functional status of the hand after radial artery harvesting: Results in 3977 cases. Ann Thorac Surg 2001;72:1557-1561.
    • (2001) Ann Thorac Surg , vol.72 , pp. 1557-1561
    • Meharwal, Z.S.1    Trehan, N.2
  • 12
    • 0029909188 scopus 로고    scopus 로고
    • Safe removal of the radial artery for myocardial revascularization: A Doppler study to prevent ischemic complications to the hand
    • Pola P, Serricchio M, Flore R, Manasse E, Favuzzi A, Possati GF. Safe removal of the radial artery for myocardial revascularization: a Doppler study to prevent ischemic complications to the hand. J Thorac & Cardiovasc Surg 1996;112:737-744.
    • (1996) J Thorac & Cardiovasc Surg , vol.112 , pp. 737-744
    • Pola, P.1    Serricchio, M.2    Flore, R.3    Manasse, E.4    Favuzzi, A.5    Possati, G.F.6
  • 15
    • 2342429309 scopus 로고    scopus 로고
    • Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: Comaprison with the Allen's test in 1010 patients
    • Barbeau GR, Arsenault GF, Dugas L, Simard S, Lariviere MM. Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: comaprison with the Allen's test in 1010 patients. Am Heart J 2004;147:489-493.
    • (2004) Am Heart J , vol.147 , pp. 489-493
    • Barbeau, G.R.1    Arsenault, G.F.2    Dugas, L.3    Simard, S.4    Lariviere, M.M.5
  • 16
    • 0034855647 scopus 로고    scopus 로고
    • Gadolinium-enhanced elliptically reordered three-dimensional MR angiography in the assessment of hand vascularization before radial artery harvest for coronary artery bypass grafting: First experience
    • Winterer JT, Ennker J, Scheffler K, Rosendahl U, Schafer O, Wanner M, Laubenberger J, Langer M. Gadolinium-enhanced elliptically reordered three-dimensional MR angiography in the assessment of hand vascularization before radial artery harvest for coronary artery bypass grafting: First experience. Investigat Radiol 2001;36:501-508.
    • (2001) Investigat Radiol , vol.36 , pp. 501-508
    • Winterer, J.T.1    Ennker, J.2    Scheffler, K.3    Rosendahl, U.4    Schafer, O.5    Wanner, M.6    Laubenberger, J.7    Langer, M.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.