메뉴 건너뛰기




Volumn 119, Issue 2, 1999, Pages 234-238

Loudness growth functions and EABR characteristics in digisonic cochlear implantees

Author keywords

Electrical stimulation; Electrophysiologic; Psycho physic; Relationship

Indexed keywords

ADULT; AMPLITUDE MODULATION; ARTICLE; AUDITORY STIMULATION; AUDITORY THRESHOLD; COCHLEA; ELECTROPHYSIOLOGY; ELECTROSTIMULATION; EVOKED AUDITORY RESPONSE; FEMALE; HUMAN; IMPLANTATION; LOUDNESS; MALE; PRIORITY JOURNAL; PSYCHOPHYSICS;

EID: 2442752594     PISSN: 00016489     EISSN: None     Source Type: Journal    
DOI: 10.1080/00016489950181738     Document Type: Article
Times cited : (29)

References (9)
  • 1
    • 0030968092 scopus 로고    scopus 로고
    • EABRs and surface potentials with a transcutaneous multielectrode cochlear implant
    • Stockh
    • Gallégo S, Truy E, Morgon A, Collet L. EABRs and surface potentials with a transcutaneous multielectrode cochlear implant. Acta Otolaryngol (Stockh) 1997; 117: 164-8.
    • (1997) Acta Otolaryngol , vol.117 , pp. 164-168
    • Gallégo, S.1    Truy, E.2    Morgon, A.3    Collet, L.4
  • 2
    • 2442758419 scopus 로고    scopus 로고
    • Correlation between electrical ABR and perceptual thresholds in Digisonic cochlear implants users
    • Truy E, Gallégo S, Chanal JM, Collet L, Morgon A. Correlation between electrical ABR and perceptual thresholds in Digisonic cochlear implants users. Laryngoscope 1997; 118: 554-9.
    • (1997) Laryngoscope , vol.118 , pp. 554-559
    • Truy, E.1    Gallégo, S.2    Chanal, J.M.3    Collet, L.4    Morgon, A.5
  • 4
    • 0002578776 scopus 로고
    • Sound processing and stimulation coding of Digisonic DX10 15-channel cochlear implant
    • Hochmair-Desogen and Hochmair ed.
    • Beliaeff M, Dubus P, Leveau JM, Repetto JC, Vincent P. Sound processing and stimulation coding of Digisonic DX10 15-channel cochlear implant. In: Advances in cochlear implant. Hochmair-Desogen and Hochmair ed., 1994: 198-203.
    • (1994) Advances in Cochlear Implant , pp. 198-203
    • Beliaeff, M.1    Dubus, P.2    Leveau, J.M.3    Repetto, J.C.4    Vincent, P.5
  • 5
    • 24844477303 scopus 로고    scopus 로고
    • Modelling of the electrical stimulation delivered by the Digisonic Multichannel cochlear implant
    • Gallégo S, Ba Lê L, Berger-Vachon C. Modelling of the electrical stimulation delivered by the Digisonic Multichannel cochlear implant. Adv Model Anal 1998; 53: 1-15.
    • (1998) Adv Model Anal , vol.53 , pp. 1-15
    • Gallégo, S.1    Ba Lê, L.2    Berger-Vachon, C.3
  • 6
    • 0023873504 scopus 로고
    • Prediction of dynamic range from stapedius reflex in cochlear implanted patients
    • Jerger H, Olivier TA, Chmiel RA. Prediction of dynamic range from stapedius reflex in cochlear implanted patients. Ear Hear 1988; 9: 4-8.
    • (1988) Ear Hear , vol.9 , pp. 4-8
    • Jerger, H.1    Olivier, T.A.2    Chmiel, R.A.3
  • 8
    • 0010358612 scopus 로고    scopus 로고
    • Electrically auditory brainstem responses (EABR): Contribution of a filter adapted to the auditory system. World Congress on Medical Physics and Biomedical Engineering. Nice, 14-19 September 1997
    • Gallégo S, Collet L, Berger-Vachon C. Electrically auditory brainstem responses (EABR): contribution of a filter adapted to the auditory system. World Congress on Medical Physics and Biomedical Engineering. Nice, 14-19 September 1997. Med Biol Eng Comput 1997; 35 (Suppl 1): 304.
    • (1997) Med Biol Eng Comput , vol.35 , Issue.1 SUPPL. , pp. 304
    • Gallégo, S.1    Collet, L.2    Berger-Vachon, C.3
  • 9
    • 0023716867 scopus 로고
    • Electrically evoked brainstem potentials in cochlear implant patients with multi-electrode stimulation
    • Abbas PJ, Brown CJ. Electrically evoked brainstem potentials in cochlear implant patients with multi-electrode stimulation. Hear Res 1988; 36: 153-62.
    • (1988) Hear Res , vol.36 , pp. 153-162
    • Abbas, P.J.1    Brown, C.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.