메뉴 건너뛰기




Volumn 31, Issue 1, 2004, Pages 105-110

Effect and control on temperature measurement accuracy of real-time temperature measurement system by reflection radiation and detector radiation itself

Author keywords

Measurement instrument; Pyroelectric detector; Radiation by reflection; Temperature measurement; Temperature measurement by radiation; Temperature measurement error

Indexed keywords

MEASUREMENT ERRORS; TEMPERATURE MEASURING INSTRUMENTS;

EID: 2442699413     PISSN: 02587025     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (11)
  • 1
    • 84883690468 scopus 로고
    • Noncontact temperature measurement. I. Interpolation based techniques
    • M. A. Khan, C. Allemand, T. W. Eagar. Noncontact temperature measurement. I. Interpolation based techniques [J]. Rev. Sci. Instrum., 1991, 62(2): 392-402
    • (1991) Rev. Sci. Instrum. , vol.62 , Issue.2 , pp. 392-402
    • Khan, M.A.1    Allemand, C.2    Eagar, T.W.3
  • 2
    • 0142206660 scopus 로고
    • Reference wavelength method for a two-color pyrometer
    • J. W. Hahn, C. Rhee. Reference wavelength method for a two-color pyrometer [J]. Appl. Opt., 1987, 26(24): 5276-5279
    • (1987) Appl. Opt. , vol.26 , Issue.24 , pp. 5276-5279
    • Hahn, J.W.1    Rhee, C.2
  • 3
    • 0022160820 scopus 로고
    • Multiwavelength pyrometer: An improved method
    • G. B. Hunter, C. D. Allemand, T. W. Eagar. Multiwavelength pyrometer: an improved method [J]. Opt. Eng., 1985, 24(6): 1081-1085
    • (1985) Opt. Eng. , vol.24 , Issue.6 , pp. 1081-1085
    • Hunter, G.B.1    Allemand, C.D.2    Eagar, T.W.3
  • 4
    • 0022693756 scopus 로고
    • Inferring temperature from optical radiation measurements
    • D. P. DeWitt. Inferring temperature from optical radiation measurements [J]. Opt. Eng., 1986, 25(4): 596-601
    • (1986) Opt. Eng. , vol.25 , Issue.4 , pp. 596-601
    • DeWitt, D.P.1
  • 5
    • 17944376225 scopus 로고    scopus 로고
    • Temperature measurement of liquids by differential absorption of two diode laser: Application of contactless optical detection in isotachophoresis
    • V. Krivtzum, B. Grab, R. Hergenroder et al.. Temperature measurement of liquids by differential absorption of two diode laser: Application of contactless optical detection in isotachophoresis [J]. Appl. Spectroscopy, 2001, 55(9): 1251-1258
    • (2001) Appl. Spectroscopy , vol.55 , Issue.9 , pp. 1251-1258
    • Krivtzum, V.1    Grab, B.2    Hergenroder, R.3
  • 6
    • 0034313276 scopus 로고    scopus 로고
    • Laser-based measurement of temperature or concentration change at liquid surfaces
    • C. H. Fan, J. P. Longtin. Laser-based measurement of temperature or concentration change at liquid surfaces [J]. Journal of Heat Transfer, Transactions ASME, 2000, 122(4): 757-762
    • (2000) Journal of Heat Transfer, Transactions ASME , vol.122 , Issue.4 , pp. 757-762
    • Fan, C.H.1    Longtin, J.P.2
  • 7
    • 0034226272 scopus 로고    scopus 로고
    • Technique for measuring distributed temperature with 35-cm spatial resolution utilizing the Landau-Placzek ratio
    • H. H. Kee, G. P. Lees, T. P. Newson. Technique for measuring distributed temperature with 35-cm spatial resolution utilizing the Landau-Placzek ratio [J]. IEEE Photon. Technol. Lett., 2000, 12(7): 873-875
    • (2000) IEEE Photon. Technol. Lett. , vol.12 , Issue.7 , pp. 873-875
    • Kee, H.H.1    Lees, G.P.2    Newson, T.P.3
  • 8
    • 0142206661 scopus 로고    scopus 로고
    • Radiation thermometer for determining temperature and emissivity
    • Hu Ruihua, Luan Song, Sun Ningke. Radiation thermometer for determining temperature and emissivity [J]. Infrared Technology, 1998, 20(2): 21-22, 17
    • (1998) Infrared Technology , vol.20 , Issue.2
    • Hu, R.1    Luan, S.2    Sun, N.3
  • 9
    • 0142168022 scopus 로고    scopus 로고
    • Working wavelength optimization of a practical real-time temperature measurement system
    • Shi Deheng, Huang Guoqing, Liu Yufang. Working wavelength optimization of a practical real-time temperature measurement system [J]. Chinese J. Lasers, 2003, 30(6): 545-550
    • (2003) Chinese J. Lasers , vol.30 , Issue.6 , pp. 545-550
    • Shi, D.1    Huang, G.2    Liu, Y.3
  • 10
    • 2442710328 scopus 로고    scopus 로고
    • Measures on improving sampling accuracy of temperature real-time measurement system
    • Shi Deheng, Xu Qifu, Chen Yuke et al.. Measures on improving sampling accuracy of temperature real-time measurement system [J]. Laser Journal, 2001, 22(1): 41-43
    • (2001) Laser Journal , vol.22 , Issue.1 , pp. 41-43
    • Shi, D.1    Xu, Q.2    Chen, Y.3
  • 11
    • 0036554217 scopus 로고    scopus 로고
    • Measures to improve the accuracy of a real-time temperature measurement system
    • Shi Deheng, Xu Qifu, Chen Yuke et al.. Measures to improve the accuracy of a real-time temperature measurement system [J]. Laser Technology, 2002, 26(2): 90-93
    • (2002) Laser Technology , vol.26 , Issue.2 , pp. 90-93
    • Shi, D.1    Xu, Q.2    Chen, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.