메뉴 건너뛰기




Volumn 15, Issue 3, 2004, Pages 192-195

Bioabsorbable instrumentation in treatment of cervical degenerative and traumatic disorders

Author keywords

Bioresorbable implants; Cervical spine degenerative disorders; Spinal instrumentation; Traumatic disorders of the cervical spine

Indexed keywords

METAL; POLYMER;

EID: 2442600502     PISSN: 10419918     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.bco.0000124215.61633.6a     Document Type: Review
Times cited : (3)

References (19)
  • 1
    • 0013965320 scopus 로고
    • Polylactic acid for surgical implants
    • Kulkarni R, Pani K, Neuman C, et al.: Polylactic acid for surgical implants. Arch Surg 1966, 93:839.
    • (1966) Arch Surg , vol.93 , pp. 839
    • Kulkarni, R.1    Pani, K.2    Neuman, C.3
  • 2
    • 0014974494 scopus 로고
    • Tissue reaction to the biodegradable polylactic acid suture
    • Cutright DE, Hunsuck EE: Tissue reaction to the biodegradable polylactic acid suture. Oral Surg Oral Med Oral Pathol 1971, 33:128-134.
    • (1971) Oral Surg Oral Med Oral Pathol , vol.33 , pp. 128-134
    • Cutright, D.E.1    Hunsuck, E.E.2
  • 3
    • 0032917632 scopus 로고    scopus 로고
    • Bone tissue response to biodegradable polymers used for intramedullary fixation: A long-term in vivo study in sheep femora
    • Van der Elst M, Klein CP, Blieck-Hogervast J, et al.: Bone tissue response to biodegradable polymers used for intramedullary fixation: a long-term in vivo study in sheep femora. Biomaterials 1999, 20:121-128.
    • (1999) Biomaterials , vol.20 , pp. 121-128
    • Van Der Elst, M.1    Klein, C.P.2    Blieck-Hogervast, J.3
  • 4
    • 0038051473 scopus 로고    scopus 로고
    • Adverse tissue reaction to bioabsorbable fixation devices
    • Bostman O, Pihlajamaki H: Adverse tissue reaction to bioabsorbable fixation devices. Clin Orthop 2000, 371:216-217.
    • (2000) Clin Orthop , vol.371 , pp. 216-217
    • Bostman, O.1    Pihlajamaki, H.2
  • 5
    • 0017536083 scopus 로고
    • Degradation rates of oral resorbable implants: Rate modification with changes in PLA/PGA copolymer ratio
    • Miller RA, Brady JM, Cutright DE: Degradation rates of oral resorbable implants: rate modification with changes in PLA/PGA copolymer ratio. J Biomed Mater Res 1977, 20:711-719.
    • (1977) J Biomed Mater Res , vol.20 , pp. 711-719
    • Miller, R.A.1    Brady, J.M.2    Cutright, D.E.3
  • 6
    • 0022738051 scopus 로고
    • Biodegradable bone repair materials. Synthetic polymers and ceramics
    • Hollinger JO, Battisone GC: Biodegradable bone repair materials. Synthetic polymers and ceramics. Clin Orthop 1986, 207:290.
    • (1986) Clin Orthop , vol.207 , pp. 290
    • Hollinger, J.O.1    Battisone, G.C.2
  • 7
    • 0037345812 scopus 로고    scopus 로고
    • Suitability of bioresorbable cages for anterior cervical fusion
    • Cahill DW, Martin GJ, Hajjar MV, et al.: Suitability of bioresorbable cages for anterior cervical fusion. J Neurosurg 2003, 98:195-201. The authors conducted a pilot study to determine whether a bioresorbable intervertebral fusion device composed of 85/15 polylactide-polyglycolide (PLA-PGA) copolymer packed with bone autograft is a suitable alternative to promote arthrodesis after cervical diskectomy (ACD) in a caprine model.
    • (2003) J Neurosurg , vol.98 , pp. 195-201
    • Cahill, D.W.1    Martin, G.J.2    Hajjar, M.V.3
  • 8
    • 0033959031 scopus 로고    scopus 로고
    • Increased fusion rates with cervical plating for two-level anterior cervical discectomy and fusion
    • Wang J, McDonough PW, Endow K, et al.: Increased fusion rates with cervical plating for two-level anterior cervical discectomy and fusion. Spine 2000, 25:41-45.
    • (2000) Spine , vol.25 , pp. 41-45
    • Wang, J.1    McDonough, P.W.2    Endow, K.3
  • 9
    • 0033496592 scopus 로고    scopus 로고
    • The effect of cervical plating on single level anterior cervical discectomy and fusion
    • Wang J, McDonough PW, Endow K, et al.: The effect of cervical plating on single level anterior cervical discectomy and fusion. J Spinal Disord 1999, 12:467-471.
    • (1999) J Spinal Disord , vol.12 , pp. 467-471
    • Wang, J.1    McDonough, P.W.2    Endow, K.3
  • 10
    • 0036481792 scopus 로고    scopus 로고
    • Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft
    • Kaiser MG, Haid RW, Subach BR, et al.: Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft. Neurosurgery 2002, 50:229-238.
    • (2002) Neurosurgery , vol.50 , pp. 229-238
    • Kaiser, M.G.1    Haid, R.W.2    Subach, B.R.3
  • 11
    • 0344689837 scopus 로고    scopus 로고
    • Anterior cervical discectomy with freeze-dried fibula allogrart
    • Martin GJ, Haid RW, MacMillan M, et al.: Anterior cervical discectomy with freeze-dried fibula allogrart. Spine 1999, 24:852-859.
    • (1999) Spine , vol.24 , pp. 852-859
    • Martin, G.J.1    Haid, R.W.2    MacMillan, M.3
  • 12
    • 0037102511 scopus 로고    scopus 로고
    • IGF-I and TGF-B1 Application by a poly-(D,L-Lactide)-coated cages promotes intervertebral bone matrix formation in the sheep cervical spine
    • Kandziora F, Schmidmaier G, Schollmeier G, et al.: IGF-I and TGF-B1 Application by a poly-(D,L-Lactide)-coated cages promotes intervertebral bone matrix formation in the sheep cervical spine. Spine 2002, 16:1710-1723.
    • (2002) Spine , vol.16 , pp. 1710-1723
    • Kandziora, F.1    Schmidmaier, G.2    Schollmeier, G.3
  • 13
    • 0036804388 scopus 로고    scopus 로고
    • Feasibility of a resorbable anterior cervical graft containment plate
    • Ames C, Crawford N, Chamberlain R, et al.: Feasibility of a resorbable anterior cervical graft containment plate. Orthopedics 2002, 25(suppl 10):1149-1155. The authors review the history of anterior cervical plating for one- and two-level diskectomy for degenerative disease and provide background justification for the design and testing of a cervical plate composed of a resorbable material. The cadaveric and animal in vivo testing methodologies are described, and a novel testing method for reliably quantifying graft containment is also described. Data from a representative sample are presented.
    • (2002) Orthopedics , vol.25 , Issue.10 SUPPL. , pp. 1149-1155
    • Ames, C.1    Crawford, N.2    Chamberlain, R.3
  • 14
    • 0036153894 scopus 로고    scopus 로고
    • In vitro antibiotic release from poly(3-hydroxybutyrate-co-3- hydroxyvalerate) rods
    • Gurselt I, Yagmurlu F, Korkusuz F, et al.: In vitro antibiotic release from poly(3-hydroxybutyrate-co-3-hydroxyvalerate) rods. J Microencaps 2002, 19:153-184.
    • (2002) J Microencaps , vol.19 , pp. 153-184
    • Gurselt, I.1    Yagmurlu, F.2    Korkusuz, F.3
  • 15
    • 0038580582 scopus 로고    scopus 로고
    • Treatment of osteomyelitis with local antibiotics delivered via bioabsorbable polymer
    • Rutledge B, Huyette D, Day D, et al.: Treatment of osteomyelitis with local antibiotics delivered via bioabsorbable polymer. Clin Orthop 2003, 411:280-287. The purpose of this study was to show the efficacy and safety of an absorbable polymer (polycaprolactone) as an antibiotic delivery vehicle for treatment of osteomyelitis. The authors concluded that bioresorbable rods of polycaprolactone are a safe and effective means of antibiotic delivery for treatment of osteomyelitis.
    • (2003) Clin Orthop , vol.411 , pp. 280-287
    • Rutledge, B.1    Huyette, D.2    Day, D.3
  • 17
    • 0028049434 scopus 로고
    • Anterior osteosynthesis of cervical spine by phusiline bioabsorbable screws and plates. Initial results apropos of five cases
    • Brunon J, Duthel R, Fotso MJ, et al.: Anterior osteosynthesis of cervical spine by phusiline bioabsorbable screws and plates. Initial results apropos of five cases. Neurochirurgie 1994, 40:196-202.
    • (1994) Neurochirurgie , vol.40 , pp. 196-202
    • Brunon, J.1    Duthel, R.2    Fotso, M.J.3
  • 18
    • 0036830269 scopus 로고    scopus 로고
    • Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disc disruption
    • Vaccaro A, Carino J, Venger B, et al.: Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disc disruption. J Neurosurg 2002, 97:473-480. This paper is a preliminary report of a prospective series in which a resorbable mesh and screw system was used for graft containment in a single-level ACDF. The results of this preliminary study indicate that bioresorbable anterior cervical plating systems for single-level ACDF are both safe and effective.
    • (2002) J Neurosurg , vol.97 , pp. 473-480
    • Vaccaro, A.1    Carino, J.2    Venger, B.3
  • 19
    • 0036830269 scopus 로고    scopus 로고
    • Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disc disruption
    • Vaccaro A, Carino J, Venger B, et al.: Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disc disruption. J Neurosurg 2002, 97:473-480.
    • (2002) J Neurosurg , vol.97 , pp. 473-480
    • Vaccaro, A.1    Carino, J.2    Venger, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.