메뉴 건너뛰기




Volumn 30, Issue 2, 2004, Pages 107-109

Comparison instrumentation time of conventional reamers and files versus a new, noninterrupted, flat-sided design

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COMPARATIVE STUDY; DEVICE; IN VITRO STUDY; INSTRUMENTATION; SAMPLING; TIME; ANALYSIS OF VARIANCE; DENTAL CARE; ENDODONTICS; EQUIPMENT DESIGN; HISTOLOGY; HUMAN; MATERIALS TESTING; SURFACE PROPERTY; TOOTH PULP; TOOTH ROOT;

EID: 2442591483     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004770-200402000-00011     Document Type: Article
Times cited : (15)

References (7)
  • 1
    • 0035432084 scopus 로고    scopus 로고
    • Influence of structure on nickel-titanium endodontic instruments failure
    • Kuhn G, Tavernier B, Jordan L. Influence of structure on nickel-titanium endodontic instruments failure. J Endodon 2001;27:516-20.
    • (2001) J Endodon , vol.27 , pp. 516-520
    • Kuhn, G.1    Tavernier, B.2    Jordan, L.3
  • 2
    • 0031064647 scopus 로고    scopus 로고
    • Cyclic fatigue testing of nickel-titanium endodontic instruments
    • Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endodon 1997;23:77-85.
    • (1997) J Endodon , vol.23 , pp. 77-85
    • Pruett, J.P.1    Clement, D.J.2    Carnes, D.L.3
  • 3
    • 0033147312 scopus 로고    scopus 로고
    • Dynamic, and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    • Haikel Y, Serfaty R, Bateman G, Senger B, Allemann C. Dynamic, and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments. J Endodon 1999;25:434-40.
    • (1999) J Endodon , vol.25 , pp. 434-440
    • Haikel, Y.1    Serfaty, R.2    Bateman, G.3    Senger, B.4    Allemann, C.5
  • 4
    • 0036366281 scopus 로고    scopus 로고
    • Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files
    • Yared G, Dagher F, Machtou P, Kulkarni G. Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files. Intern Endodon J 2002;35:7-12.
    • (2002) Intern Endodon J , vol.35 , pp. 7-12
    • Yared, G.1    Dagher, F.2    Machtou, P.3    Kulkarni, G.4
  • 5
    • 0036632661 scopus 로고    scopus 로고
    • The effect of preflaring on the rates of separation for .04 taper nickel titanium rotary instruments
    • Roland D, Andelin W, Browning D, Hsu G, Torabinejad M. The effect of preflaring on the rates of separation for .04 taper nickel titanium rotary instruments. J Endodon 2002;28:543-5.
    • (2002) J Endodon , vol.28 , pp. 543-545
    • Roland, D.1    Andelin, W.2    Browning, D.3    Hsu, G.4    Torabinejad, M.5
  • 6
    • 0031083690 scopus 로고    scopus 로고
    • Properties of endodontic hand instruments used in rotary motion, part 3: Resistance to bending and fracture
    • Tepel J, Schafer E, Hoppe W. Properties of endodontic hand instruments used in rotary motion, part 3: resistance to bending and fracture. J Endodon 1997;23:141-6.
    • (1997) J Endodon , vol.23 , pp. 141-146
    • Tepel, J.1    Schafer, E.2    Hoppe, W.3
  • 7
    • 0031108236 scopus 로고    scopus 로고
    • Torsional properties of nickel-titanium versus stainless steel endodontic files
    • Wolcott J, Himel VT. Torsional properties of nickel-titanium versus stainless steel endodontic files. J Endodon 1997;23:217-20.
    • (1997) J Endodon , vol.23 , pp. 217-220
    • Wolcott, J.1    Himel, V.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.