메뉴 건너뛰기




Volumn 27, Issue 6, 2004, Pages 629-634

Toe blood pressure measurements in patients suspected of leg ischaemia: A new laser Doppler device compared with photoplethysmography

Author keywords

Laser Doppler; Leg ischaemia; Photoplethysmography; Toe blood pressure

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD PRESSURE MEASUREMENT; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CUFF; DEVICE; FEMALE; HEATING; HUMAN; INTERMETHOD COMPARISON; LASER DOPPLER FLOWMETRY; LASER FLOWMETER; LEG ARTERY; LEG ISCHEMIA; MAJOR CLINICAL STUDY; MALE; PATIENT REFERRAL; PHOTOELECTRIC PLETHYSMOGRAPHY; PRIORITY JOURNAL; PROSPECTIVE STUDY; STATISTICAL ANALYSIS; SYSTOLIC BLOOD PRESSURE; TOE;

EID: 2442568717     PISSN: 10785884     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejvs.2004.01.031     Document Type: Article
Times cited : (40)

References (18)
  • 1
    • 0020615631 scopus 로고
    • Toe blood pressure: A valuable adjunct to ankle pressure measurement for assessing peripheral arterial disease
    • Ramsey DE, Manke DA, Sumner DS. Toe blood pressure: a valuable adjunct to ankle pressure measurement for assessing peripheral arterial disease. J Cardiovasc Surg 1983; 24:43-48.
    • (1983) J. Cardiovasc. Surg. , vol.24 , pp. 43-48
    • Ramsey, D.E.1    Manke, D.A.2    Sumner, D.S.3
  • 2
    • 0020585229 scopus 로고
    • Noninvasive assessment of toe systolic pressures with special reference to diabetes mellitus
    • Vincent DG, Salles-Cunha SX, Bernhard VM, Towne JB. Noninvasive assessment of toe systolic pressures with special reference to diabetes mellitus. J Cardiovasc Surg 1983; 24:22-28.
    • (1983) J. Cardiovasc. Surg. , vol.24 , pp. 22-28
    • Vincent, D.G.1    Salles-Cunha, S.X.2    Bernhard, V.M.3    Towne, J.B.4
  • 3
    • 0141501083 scopus 로고    scopus 로고
    • Evaluation of toe pressure and transcutaneous oxygen measurements in management of chronic critical leg ischemia: A diagnostic randomized clinical trial
    • De Graaff JC, Ubbink DT, Legemate DA, Tijssen JG, Jacobs MJ. Evaluation of toe pressure and transcutaneous oxygen measurements in management of chronic critical leg ischemia: a diagnostic randomized clinical trial. J Vasc Surg 2003; 38:528-534.
    • (2003) J. Vasc. Surg. , vol.38 , pp. 528-534
    • De Graaff, J.C.1    Ubbink, D.T.2    Legemate, D.A.3    Tijssen, J.G.4    Jacobs, M.J.5
  • 6
    • 0018842580 scopus 로고
    • Prognostic significance of distal blood pressure measurements in patients with severe ischaemia
    • Paaske WP, Tonnesen KH. Prognostic significance of distal blood pressure measurements in patients with severe ischaemia. Scand J Thorac Cardiovasc Surg 1980; 14:105-108.
    • (1980) Scand. J. Thorac. Cardiovasc. Surg. , vol.14 , pp. 105-108
    • Paaske, W.P.1    Tonnesen, K.H.2
  • 7
    • 0034201615 scopus 로고    scopus 로고
    • Management of peripheral arterial disease (PAD) TransAtlantic Inter-Society Consensus (TASC). Section D, Critical limb ischaemia: Definition and nomenclature of chronic critical limb ischaemia
    • Anonymous
    • Anonymous, Management of peripheral arterial disease (PAD). TransAtlantic Inter-Society Consensus (TASC). Section D, Critical limb ischaemia: Definition and nomenclature of chronic critical limb ischaemia, Eur J Vasc Endovasc Surg 2000; 19(Suppl. A):S144-243.
    • (2000) Eur. J. Vasc. Endovasc. Surg. , vol.19 , Issue.SUPPL. A
  • 8
    • 0001995236 scopus 로고
    • Diagnosis and objective evaluation of digital systolic blood pressure by strain-gauge technique
    • Strandness Jr. De, Bell JW. Diagnosis and objective evaluation of digital systolic blood pressure by strain-gauge technique. Ann Surg 1965; 161(Suppl. 4):3.
    • (1965) Ann. Surg. , vol.161 , Issue.SUPPL. 4 , pp. 3
    • Strandness Jr., De.1    Bell, J.W.2
  • 9
    • 0021355161 scopus 로고
    • Noninvasive vascular diagnostic testing: Techniques and clinical applications
    • Yao JS, Flinn WR, Bergan JJ. Noninvasive vascular diagnostic testing: techniques and clinical applications. Prog Cardiovasc Dis 1984; 26:459-494.
    • (1984) Prog. Cardiovasc. Dis. , vol.26 , pp. 459-494
    • Yao, J.S.1    Flinn, W.R.2    Bergan, J.J.3
  • 10
    • 0035347255 scopus 로고    scopus 로고
    • Interobserver and intraobserver reproducibility of peripheral blood and oxygen pressure measurements in the assessment of lower extremity arterial disease
    • De Graaff JC, Ubbink DT, Legemate DA, De Haan RJ, Jacobs MJ. Interobserver and intraobserver reproducibility of peripheral blood and oxygen pressure measurements in the assessment of lower extremity arterial disease. J Vasc Surg 2001; 33:1033-1040.
    • (2001) J. Vasc. Surg. , vol.33 , pp. 1033-1040
    • De Graaff, J.C.1    Ubbink, D.T.2    Legemate, D.A.3    De Haan, R.J.4    Jacobs, M.J.5
  • 13
    • 0036782679 scopus 로고    scopus 로고
    • A new automated toe blood pressure monitor for assessment of limb ischemia
    • Wahlberg E, Gush R. A new automated toe blood pressure monitor for assessment of limb ischemia. Eur J Vasc Endovasc Surg 2002; 24:304-308.
    • (2002) Eur. J. Vasc. Endovasc. Surg. , vol.24 , pp. 304-308
    • Wahlberg, E.1    Gush, R.2
  • 14
    • 0025851102 scopus 로고
    • Reproducibility and responsiveness of health status measures: Statistics and strategies for evaluation
    • Deyo RA, Diehr P, Patrick DL. Reproducibility and responsiveness of health status measures: statistics and strategies for evaluation. Control Clin Trials 1991; 12:142S-158S.
    • (1991) Control Clin. Trials , vol.12
    • Deyo, R.A.1    Diehr, P.2    Patrick, D.L.3
  • 15
    • 0021982047 scopus 로고
    • A methodological framework for assessing health indices
    • Kirshner B, Guyatt G. A methodological framework for assessing health indices. J Chronic Dis 1985; 38:27-36.
    • (1985) J. Chronic Dis. , vol.38 , pp. 27-36
    • Kirshner, B.1    Guyatt, G.2
  • 16
    • 0028791287 scopus 로고
    • Comparing methods of measurement: Why plotting difference against standard method is misleading
    • Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 1995; 346:1085-1087.
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0022547319 scopus 로고
    • A laser Doppler technique for measuring distal blood-pressure: A comparison with conventional strain-gauge technique
    • Andersson S, Linderholm H, Rinnstrom O, Burlin L. A laser Doppler technique for measuring distal blood-pressure: a comparison with conventional strain-gauge technique. Clin Physiol 1986; 6:329-335.
    • (1986) Clin. Physiol. , vol.6 , pp. 329-335
    • Andersson, S.1    Linderholm, H.2    Rinnstrom, O.3    Burlin, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.