-
1
-
-
0028086917
-
Amperometric biosensor based on carbon paste mixed with enzyme lipid and cytochrome C
-
Amine A., Deni J., Kauffmann J.-M. Amperometric biosensor based on carbon paste mixed with enzyme lipid and cytochrome C. Bioelectrochem. Bioenerg. 34:1994;123-128
-
(1994)
Bioelectrochem. Bioenerg.
, vol.34
, pp. 123-128
-
-
Amine, A.1
Deni, J.2
Kauffmann, J.-M.3
-
2
-
-
0028107679
-
2 immobilized in a poly(phenol) film
-
2 immobilized in a poly(phenol) film. Analyst. 119:1994;175-180
-
(1994)
Analyst
, vol.119
, pp. 175-180
-
-
Bartlett, P.N.1
Caruana, D.J.2
-
3
-
-
0029308898
-
A continuous, implantable lactate sensor
-
Baker D.A., Gough D.A. A continuous, implantable lactate sensor. Anal. Chem. 67:1995;1536-1540
-
(1995)
Anal. Chem.
, vol.67
, pp. 1536-1540
-
-
Baker, D.A.1
Gough, D.A.2
-
4
-
-
0030024779
-
Serial blood lactate levels can predict the development of multiple organ failure following septic shock
-
Bakker J., Gris P., Coffernils M., Kahn R.J., Vincent J.L. Serial blood lactate levels can predict the development of multiple organ failure following septic shock. Am. J. Surg. 171:1996;221-226
-
(1996)
Am. J. Surg.
, vol.171
, pp. 221-226
-
-
Bakker, J.1
Gris, P.2
Coffernils, M.3
Kahn, R.J.4
Vincent, J.L.5
-
5
-
-
0035663070
-
Immobilization of lactate dehydrogenase on tetraethylorthosilicate- derived sol-gel films for application to lactate biosensor
-
Chaubey A., Gerard M., Singh V.S., Malhotra B.D. Immobilization of lactate dehydrogenase on tetraethylorthosilicate-derived sol-gel films for application to lactate biosensor. Appl. Biochem. Biotechnol. 96:2001;293-301
-
(2001)
Appl. Biochem. Biotechnol.
, vol.96
, pp. 293-301
-
-
Chaubey, A.1
Gerard, M.2
Singh, V.S.3
Malhotra, B.D.4
-
6
-
-
0003737694
-
Lactate blood levels in the perioperative period of orthotopic liver transplantation
-
DeGasperi A., Mazza E., Corti A., Zoppi F., Prosperi M., Fantini G., Scaiola A., Colella G., Amici O., Notaro P., Rochini A., Ceresa F., Roselli E., Grugni M.C. Lactate blood levels in the perioperative period of orthotopic liver transplantation. Int. J. Clin. Lab. 27:1997;123-128
-
(1997)
Int. J. Clin. Lab.
, vol.27
, pp. 123-128
-
-
Degasperi, A.1
Mazza, E.2
Corti, A.3
Zoppi, F.4
Prosperi, M.5
Fantini, G.6
Scaiola, A.7
Colella, G.8
Amici, O.9
Notaro, P.10
Rochini, A.11
Ceresa, F.12
Roselli, E.13
Grugni, M.C.14
-
8
-
-
0023718595
-
Blood lactate during exercise: Time course of training adaptation in humans
-
Gaesser G.A., Poole D.C. Blood lactate during exercise: time course of training adaptation in humans. Int. J. Sports Med. 9:1988;284-288
-
(1988)
Int. J. Sports Med.
, vol.9
, pp. 284-288
-
-
Gaesser, G.A.1
Poole, D.C.2
-
9
-
-
0032522098
-
A bienzyme electrode for L-malate based on a novel and general design
-
Gajovic N., Warsinke A., Scheller F.W. A bienzyme electrode for L-malate based on a novel and general design. J. Biotechnol. 61:1998;129-133
-
(1998)
J. Biotechnol.
, vol.61
, pp. 129-133
-
-
Gajovic, N.1
Warsinke, A.2
Scheller, F.W.3
-
10
-
-
0014318045
-
Optimum reaction conditions for human lactate dehydrogenase isoenzyme as they affect total lactate dehydrogenase activity
-
Gay R.S., MaComb R.B., Bowers G.N. Jr. Optimum reaction conditions for human lactate dehydrogenase isoenzyme as they affect total lactate dehydrogenase activity. Clin. Chem. 14:1968;740-747
-
(1968)
Clin. Chem.
, vol.14
, pp. 740-747
-
-
Gay, R.S.1
MacOmb, R.B.2
Bowers Jr., G.N.3
-
11
-
-
0036329224
-
An amperometric biosensor for determining amino acids using a bienzymatic system containing amino acid oxidase and protease
-
Kwan R.C.H., Chan C., Renneberg R. An amperometric biosensor for determining amino acids using a bienzymatic system containing amino acid oxidase and protease. Biotechnol. Lett. 24:2002;1203-1207
-
(2002)
Biotechnol. Lett.
, vol.24
, pp. 1203-1207
-
-
Kwan, R.C.H.1
Chan, C.2
Renneberg, R.3
-
12
-
-
0000096485
-
Phosphate sensor composed from immobilized pyruvate oxidase and an oxygen electrode
-
Kubo I., Inagawa M., Sugawara T., Arikawa Y., Karube I. Phosphate sensor composed from immobilized pyruvate oxidase and an oxygen electrode. Anal. Lett. 24:1991;1711-1727
-
(1991)
Anal. Lett.
, vol.24
, pp. 1711-1727
-
-
Kubo, I.1
Inagawa, M.2
Sugawara, T.3
Arikawa, Y.4
Karube, I.5
-
13
-
-
0242540901
-
An enzymatic microassay for lactate concentration in blood and hemolymph
-
Lin C.Y., Chen S.H., Kou G.H., Kuo C.M. An enzymatic microassay for lactate concentration in blood and hemolymph. Acta Zool. Taiwan. 10:1999;91-101
-
(1999)
Acta Zool. Taiwan
, vol.10
, pp. 91-101
-
-
Lin, C.Y.1
Chen, S.H.2
Kou, G.H.3
Kuo, C.M.4
-
14
-
-
0000986233
-
Reagentless amperometric biosensor highly sensitive to hydrogen peroxide based on the incorporation of Meldola Blue, fumed-silica and horseradish peroxidase into carbon paste
-
Liu H., Zhang Z., Fan Y., Deng J., Qi D. Reagentless amperometric biosensor highly sensitive to hydrogen peroxide based on the incorporation of Meldola Blue, fumed-silica and horseradish peroxidase into carbon paste. Fresenius J. Anal. Chem. 357:1997;297-301
-
(1997)
Fresenius J. Anal. Chem.
, vol.357
, pp. 297-301
-
-
Liu, H.1
Zhang, Z.2
Fan, Y.3
Deng, J.4
Qi, D.5
-
15
-
-
0030739976
-
A bienzyme-poly-(o-phenylenediamine)-modified carbon paste electrode for the amperometric detection of L-lactate
-
Lobo-Castannon M.J., Miranda-Ordieres A.J., Tunon-Blanco P. A bienzyme-poly-(o-phenylenediamine)-modified carbon paste electrode for the amperometric detection of L-lactate. Anal. Chim. Acta. 346:1997;165-174
-
(1997)
Anal. Chim. Acta
, vol.346
, pp. 165-174
-
-
Lobo-Castannon, M.J.1
Miranda-Ordieres, A.J.2
Tunon-Blanco, P.3
-
16
-
-
0037684773
-
An amperometric bi-enzyme sensor for determination of formate using cofactor regeneration
-
Mak K.K.W., Wollenberger U., Scheller F.W., Renneberg R. An amperometric bi-enzyme sensor for determination of formate using cofactor regeneration. Biosens. Bioelectron. 18:2003;1095-1100
-
(2003)
Biosens. Bioelectron.
, vol.18
, pp. 1095-1100
-
-
Mak, K.K.W.1
Wollenberger, U.2
Scheller, F.W.3
Renneberg, R.4
-
17
-
-
0030787453
-
A conducting salt-based amperometric biosensor for measurement of extracellular lactate accumulation in ischemic myocardium
-
Marzouk S.A.M., Cosofret V.V., Buch R.P., Yang H., Cascio W.E., Hassan S.S.M. A conducting salt-based amperometric biosensor for measurement of extracellular lactate accumulation in ischemic myocardium. Anal. Chem. 69:1997;2646-2652
-
(1997)
Anal. Chem.
, vol.69
, pp. 2646-2652
-
-
Marzouk, S.A.M.1
Cosofret, V.V.2
Buch, R.P.3
Yang, H.4
Cascio, W.E.5
Hassan, S.S.M.6
-
18
-
-
0003025034
-
A lactate electrode with lactate oxidase immobilized on nylon net for blood serum samples in flow system
-
Mascini M., Moscone D., Palleschi G. A lactate electrode with lactate oxidase immobilized on nylon net for blood serum samples in flow system. Anal Chim. Acta. 157:1984;45-51
-
(1984)
Anal Chim. Acta
, vol.157
, pp. 45-51
-
-
Mascini, M.1
Moscone, D.2
Palleschi, G.3
-
19
-
-
4244186437
-
An enzyme electrode for L-lactate with a chemically-amplified response
-
Mizutani F., Yamanaka T., Tanabe Y., Tsuda K. An enzyme electrode for L-lactate with a chemically-amplified response. Anal. Chim. Acta. 177:1985;153-166
-
(1985)
Anal. Chim. Acta
, vol.177
, pp. 153-166
-
-
Mizutani, F.1
Yamanaka, T.2
Tanabe, Y.3
Tsuda, K.4
-
20
-
-
0035580978
-
Amperometric determination of acetic acid with a trienzyme/ poly(dimethylsiloxane)-bilayer-based sensor
-
Mizutani F., Sawaguchi T., Sato Y., Yabuki S., Iijima S. Amperometric determination of acetic acid with a trienzyme/poly(dimethylsiloxane)-bilayer- based sensor. Anal. Chem. 7:2001;5738-5742
-
(2001)
Anal. Chem.
, vol.7
, pp. 5738-5742
-
-
Mizutani, F.1
Sawaguchi, T.2
Sato, Y.3
Yabuki, S.4
Iijima, S.5
-
21
-
-
0025434094
-
Lactate and glucose electrochemical biosensors for the evaluation of the aerobic and anaerobic threshold in runners
-
Palleschi G., Mascini M., Bernardi L. Lactate and glucose electrochemical biosensors for the evaluation of the aerobic and anaerobic threshold in runners. Med. Biol. Eng. Comput. 28:1990;B25-B28
-
(1990)
Med. Biol. Eng. Comput.
, vol.28
, pp. 25-B28
-
-
Palleschi, G.1
Mascini, M.2
Bernardi, L.3
-
22
-
-
0034950675
-
Flow injection analysis of L-lactate in milk and yoghurt by on-line microdialysis and amperometric detection at a disposable biosensor
-
Palmisano F., Quinto M., Rizzi R., Zambonin P.G. Flow injection analysis of L-lactate in milk and yoghurt by on-line microdialysis and amperometric detection at a disposable biosensor. Analyst. 126:2001;866-870
-
(2001)
Analyst
, vol.126
, pp. 866-870
-
-
Palmisano, F.1
Quinto, M.2
Rizzi, R.3
Zambonin, P.G.4
-
23
-
-
0030960067
-
Sol-gel based amperometric biosensor incorporating an osmium redox polymer as mediator for detection of L-lactate
-
Park T., Iwuoha E.I., Smyth M.R., Freaney R., McShane A.J. Sol-gel based amperometric biosensor incorporating an osmium redox polymer as mediator for detection of L-lactate. Talanta. 44:1997;973-978
-
(1997)
Talanta
, vol.44
, pp. 973-978
-
-
Park, T.1
Iwuoha, E.I.2
Smyth, M.R.3
Freaney, R.4
McShane, A.J.5
-
24
-
-
0032924588
-
Containment sensors for the determination of L-lactate and glucose
-
Perdomo J., Sundermeier C., Hinkers H., Martínez Morell O., Seifert W., Knoll M. Containment sensors for the determination of L-lactate and glucose. Biosens. Bioelectron. 14:1999;27-32
-
(1999)
Biosens. Bioelectron.
, vol.14
, pp. 27-32
-
-
Perdomo, J.1
Sundermeier, C.2
Hinkers, H.3
Martínez Morell, O.4
Seifert, W.5
Knoll, M.6
-
25
-
-
0030797554
-
Amperometric lactate oxidase catheter for real-time lactate monitoring based on thin-film technology
-
Pfeiffer D., Moller B., Klimes N., Szeponik J. Amperometric lactate oxidase catheter for real-time lactate monitoring based on thin-film technology. Biosens. Bioelectron. 12:1997;539-550
-
(1997)
Biosens. Bioelectron.
, vol.12
, pp. 539-550
-
-
Pfeiffer, D.1
Moller, B.2
Klimes, N.3
Szeponik, J.4
-
26
-
-
45949127361
-
Coupled enzyme reactions for novel biosensor
-
Renneberg R., Schubert F., Scheller F.W. Coupled enzyme reactions for novel biosensor. Tibtech. 11:1986;216-220
-
(1986)
Tibtech.
, vol.11
, pp. 216-220
-
-
Renneberg, R.1
Schubert, F.2
Scheller, F.W.3
-
28
-
-
0029275519
-
In vivo continuous monitoring of L-lactate coupling subcutaneous microdialysis and an electrochemical biocell
-
Volpe, G., Moscone, D., Palleschi, G., 1995. In vivo continuous monitoring of L-lactate coupling subcutaneous microdialysis and an electrochemical biocell. Sens. Actuators B: Chem. 24, 138-141.
-
(1995)
Sens. Actuators B: Chem.
, vol.24
, pp. 138-141
-
-
Volpe, G.1
Moscone, D.2
Palleschi, G.3
-
29
-
-
0024287715
-
Fiber-optic biosensors based on the fluorometric detection of reduced nicotinamide adenine dinucleotide
-
Wangsa J., Arnold M.A. Fiber-optic biosensors based on the fluorometric detection of reduced nicotinamide adenine dinucleotide. Anal. Chem. 60:1998;1080-1082
-
(1998)
Anal. Chem.
, vol.60
, pp. 1080-1082
-
-
Wangsa, J.1
Arnold, M.A.2
-
31
-
-
0028670525
-
Urea and lactate determined in 1-μl whole-blood samples with a miniaturized thermal biosensor
-
Xie B., Harborn U., Mecklenburg M., Danielsson B. Urea and lactate determined in 1-μl whole-blood samples with a miniaturized thermal biosensor. Clin. Chem. 40(12):1994;2282-2287
-
(1994)
Clin. Chem.
, vol.40
, Issue.12
, pp. 2282-2287
-
-
Xie, B.1
Harborn, U.2
Mecklenburg, M.3
Danielsson, B.4
-
32
-
-
0346453489
-
Determination of lactate with liquid chromatography/electrochemistry coupled with a lactate oxidase IMER
-
Yang L., Overdorf G., Kissinger P. Determination of lactate with liquid chromatography/electrochemistry coupled with a lactate oxidase IMER. Curr. Sep. 16:1997;15-18
-
(1997)
Curr. Sep.
, vol.16
, pp. 15-18
-
-
Yang, L.1
Overdorf, G.2
Kissinger, P.3
|