Volumn 23, Issue 5, 2004, Pages 730-734

Effect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma

Author keywords

Oasys 2; Occupational asthma; Peak expiratory flow

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MEDICAL RECORD; OCCUPATIONAL ASTHMA; OCCUPATIONAL EXPOSURE; PEAK EXPIRATORY FLOW; PRIORITY JOURNAL; QUALITY CONTROL; QUANTITATIVE ANALYSIS; SENSITIVITY AND SPECIFICITY; WORKER; WORKING TIME;

EID: 2442516559     PISSN: 09031936     EISSN: None     Source Type: Journal    
DOI: 10.1183/09031936.04.00027304     Document Type: Article
Times cited : (56)

References (11)
  • 2
    • 0018757078 scopus 로고
    • Peak flow rate records in the diagnosis of occupational asthma due to isocyanates
    • Burge PS, O'Brien I, Harries M. Peak flow rate records in the diagnosis of occupational asthma due to isocyanates. Thorax 1979; 34: 317-323.
    • (1979) Thorax , vol.34 , pp. 317-323
    • Burge, P.S.1    O'Brien, I.2    Harries, M.3
  • 3
    • 0018758717 scopus 로고
    • Peak flow rate records in the diagnosis of occupational asthma due to colophony
    • Burge PS, O'Brien I, Harries M. Peak flow rate records in the diagnosis of occupational asthma due to colophony. Thorax 1979; 34: 308-316.
    • (1979) Thorax , vol.34 , pp. 308-316
    • Burge, P.S.1    O'Brien, I.2    Harries, M.3
  • 4
    • 0025193963 scopus 로고
    • Sensitivity and specificity of PC20 and peak expiratory flow rate in cedar asthma
    • Cote J, Kennedy SM, Chan-Yeung M. Sensitivity and specificity of PC20 and peak expiratory flow rate in cedar asthma. J Allergy Clin Immunol 1990; 85: 592-598.
    • (1990) J. Allergy Clin. Immunol. , vol.85 , pp. 592-598
    • Cote, J.1    Kennedy, S.M.2    Chan-Yeung, M.3
  • 5
    • 0026601719 scopus 로고
    • Occupational asthma: Validity of monitoring of peak expiratory flow rates and non-allergic bronchial responsiveness as compared to specific inhalation challenge
    • Perrin B, Lagier F, L'Archevêque J, et al. Occupational asthma: validity of monitoring of peak expiratory flow rates and non-allergic bronchial responsiveness as compared to specific inhalation challenge. Eur Respir J 1992; 5: 40-48.
    • (1992) Eur. Respir. J. , vol.5 , pp. 40-48
    • Perrin, B.1    Lagier, F.2    L'Archevêque, J.3
  • 7
    • 0027716968 scopus 로고
    • How many times per day should peak expiratory flow rates be assessed when investigating occupational asthma?
    • Malo J, Cote J, Cartier A, Boulet L, L'Archevêque J, Chan-Yeung M. How many times per day should peak expiratory flow rates be assessed when investigating occupational asthma? Thorax 1993; 48: 1211-1217.
    • (1993) Thorax , vol.48 , pp. 1211-1217
    • Malo, J.1    Cote, J.2    Cartier, A.3    Boulet, L.4    L'Archevêque, J.5    Chan-Yeung, M.6
  • 9
    • 0032866965 scopus 로고    scopus 로고
    • Development of an expert system for the interpretation of serial peak expiratory flow measurements in the diagnosis of occupational asthma
    • Burge PS, Pantin CF, Newton DT, et al. Development of an expert system for the interpretation of serial peak expiratory flow measurements in the diagnosis of occupational asthma. Occup Environ Med 1999; 56: 758-764.
    • (1999) Occup. Environ. Med. , vol.56 , pp. 758-764
    • Burge, P.S.1    Pantin, C.F.2    Newton, D.T.3
  • 10
    • 0031709421 scopus 로고    scopus 로고
    • Effect of the number of peak expiratory flow readings per day on the estimation of diurnal variation
    • Gannon PF, Newton DT, Pantin CF, Burge PS. Effect of the number of peak expiratory flow readings per day on the estimation of diurnal variation. Thorax 1998; 53: 790-792.
    • (1998) Thorax , vol.53 , pp. 790-792
    • Gannon, P.F.1    Newton, D.T.2    Pantin, C.F.3    Burge, P.S.4
  • 11
    • 0029952706 scopus 로고    scopus 로고
    • Development of Oasys-2, a system for the analysis of serial measurements of peak expiratory flow in workers with suspected occupational asthma
    • Gannon PF, Newton DT, Belcher J, Pantin CF, Burge PS. Development of Oasys-2, a system for the analysis of serial measurements of peak expiratory flow in workers with suspected occupational asthma. Thorax 1996; 51: 484-489.
    • (1996) Thorax , vol.51 , pp. 484-489
    • Gannon, P.F.1    Newton, D.T.2    Belcher, J.3    Pantin, C.F.4    Burge, P.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.