메뉴 건너뛰기




Volumn 25, Issue 2, 2004, Pages 99-112

Assessment of Coronary Artery and Cardiac Function Using Multidetector CT

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFACT; COMPUTER ASSISTED TOMOGRAPHY; CORONARY ARTERY; CORONARY ARTERY OBSTRUCTION; ELECTROCARDIOGRAM; HEART CYCLE; HEART FUNCTION; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART VENTRICLE WALL MOTION; HUMAN; IMAGE RECONSTRUCTION; IMAGING; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; REVIEW;

EID: 2442484042     PISSN: 08872171     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sult.2003.10.003     Document Type: Article
Times cited : (15)

References (26)
  • 1
    • 2442460756 scopus 로고    scopus 로고
    • 4D (3D + cine movie) CT-Ventriculography, a new application of helical CT
    • abstr
    • Mochizuki T, Koyama Y, Tanaka H, et al: 4D (3D + cine movie) CT-Ventriculography, a new application of helical CT. Radiology 205:670-671, 1997 (abstr)
    • (1997) Radiology , vol.205 , pp. 670-671
    • Mochizuki, T.1    Koyama, Y.2    Tanaka, H.3
  • 2
    • 0034610434 scopus 로고    scopus 로고
    • Noninvasive coronary angiography by retrospectively ECG-gated multidetector spiral CT
    • Achenbach S, Ulzheimer S, Baum U, et al: Noninvasive coronary angiography by retrospectively ECG-gated multidetector spiral CT. Circulation 102:2823-2828, 2000
    • (2000) Circulation , vol.102 , pp. 2823-2828
    • Achenbach, S.1    Ulzheimer, S.2    Baum, U.3
  • 3
    • 0035941737 scopus 로고    scopus 로고
    • Coronary angiography with multidetector computed tomography
    • Nieman K, Oudkerk M, Rensing BJ, et al: Coronary angiography with multidetector computed tomography. Lancet 357:599-603, 2001
    • (2001) Lancet , vol.357 , pp. 599-603
    • Nieman, K.1    Oudkerk, M.2    Rensing, B.J.3
  • 4
    • 0036840299 scopus 로고    scopus 로고
    • Non-invasive coronary angiography with multidetector spiral computed tomography: Impact of heart rate
    • Nieman K, Rensing BJ, van Geuns RJ, et al: Non-invasive coronary angiography with multidetector spiral computed tomography: Impact of heart rate. Heart 88:470-474, 2002
    • (2002) Heart , vol.88 , pp. 470-474
    • Nieman, K.1    Rensing, B.J.2    Van Geuns, R.J.3
  • 5
    • 0035967495 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multidetector spiral computed tomography
    • Achenbach S, Giesler T, Ropers D, et al: Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multidetector spiral computed tomography. Circulation 103:2535-2538, 2001
    • (2001) Circulation , vol.103 , pp. 2535-2538
    • Achenbach, S.1    Giesler, T.2    Ropers, D.3
  • 6
    • 0037109216 scopus 로고    scopus 로고
    • Reliable noninvasive coronary angiography with fast submillimeter multidetector spiral computed tomography
    • Nieman K, Cademartiri F, Lemos PA, et al: Reliable noninvasive coronary angiography with fast submillimeter multidetector spiral computed tomography. Circulation 106:2051-2054, 2002
    • (2002) Circulation , vol.106 , pp. 2051-2054
    • Nieman, K.1    Cademartiri, F.2    Lemos, P.A.3
  • 7
    • 0037432175 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
    • Ropers D, Baum U, Pohle K, et al: Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 107:664-666, 2003
    • (2003) Circulation , vol.107 , pp. 664-666
    • Ropers, D.1    Baum, U.2    Pohle, K.3
  • 8
    • 0032168475 scopus 로고    scopus 로고
    • Left ventricular thrombus detected by two- and three-dimensional computed tomographic ventriculography: A new application of helical CT
    • Mochizuki T, Koyama Y, Tanaka H, et al: Left ventricular thrombus detected by two- and three-dimensional computed tomographic ventriculography: A new application of helical CT. Circulation 98:933-934, 1998
    • (1998) Circulation , vol.98 , pp. 933-934
    • Mochizuki, T.1    Koyama, Y.2    Tanaka, H.3
  • 9
    • 0034649252 scopus 로고    scopus 로고
    • Tricuspid atresia with atrial septal defect, ventricular septal defect, and right ventricular hypoplasia demonstrated by multidetector computed tomography
    • Mochizuki T, Ohtani T, Higashino H, et al: Tricuspid atresia with atrial septal defect, ventricular septal defect, and right ventricular hypoplasia demonstrated by multidetector computed tomography. Circulation 102:E164-E165, 2000
    • (2000) Circulation , vol.102
    • Mochizuki, T.1    Ohtani, T.2    Higashino, H.3
  • 10
    • 0033987434 scopus 로고    scopus 로고
    • Two- and three-dimensional CT ventriculography: A new application of helical CT
    • Mochizuki T, Murase K, Higashino H, et al: Two- and three-dimensional CT ventriculography: A new application of helical CT. AJR Am J Roentgenol 174:203-208, 2000
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 203-208
    • Mochizuki, T.1    Murase, K.2    Higashino, H.3
  • 11
    • 18844468293 scopus 로고    scopus 로고
    • Four-dimensional cardiac image by helical computed tomography
    • Koyama Y, Matsuoka H, Higasino H, et al: Four-dimensional cardiac image by helical computed tomography. Circulation 100:E61-E62, 1999
    • (1999) Circulation , vol.100
    • Koyama, Y.1    Matsuoka, H.2    Higasino, H.3
  • 12
    • 0035936655 scopus 로고    scopus 로고
    • Left ventricular hypertrophy demonstrated by four-dimensional myocardiography by helical computed tomography
    • Koyama Y, Matsuoka H, Higashino H, et al: Left ventricular hypertrophy demonstrated by four-dimensional myocardiography by helical computed tomography. Circulation 103: E15-E17, 2001
    • (2001) Circulation , vol.103
    • Koyama, Y.1    Matsuoka, H.2    Higashino, H.3
  • 13
  • 14
    • 0344826035 scopus 로고    scopus 로고
    • Assessment of left ventricular volumes using multi-detector row computed tomography (MDCT): Phantom and humen studies
    • Hosoi S, Mochizuki T, Miyagawa M, et al: Assessment of left ventricular volumes using multi-detector row computed tomography (MDCT): Phantom and humen studies. Radiat Med 21:62-67, 2003
    • (2003) Radiat Med , vol.21 , pp. 62-67
    • Hosoi, S.1    Mochizuki, T.2    Miyagawa, M.3
  • 15
    • 0026638401 scopus 로고
    • Quantitative assessment of myocardial enhancement with iodinated contrast medium in patients with ischemic heart disease by using ultrafast X-ray computed tomography
    • Naito H, Saito H, Takamiya M, et al: Quantitative assessment of myocardial enhancement with iodinated contrast medium in patients with ischemic heart disease by using ultrafast X-ray computed tomography. Invest Radiol 27:436-442, 1992
    • (1992) Invest Radiol , vol.27 , pp. 436-442
    • Naito, H.1    Saito, H.2    Takamiya, M.3
  • 16
    • 0033586674 scopus 로고    scopus 로고
    • Demonstration of acute myocardial infarction by subsecond spiral computed tomography: Early defect and delayed enhancement
    • Mochizuki T, Murase K, Higashino H, et al: Demonstration of acute myocardial infarction by subsecond spiral computed tomography: Early defect and delayed enhancement. Circulation 99:2058-2059, 1999
    • (1999) Circulation , vol.99 , pp. 2058-2059
    • Mochizuki, T.1    Murase, K.2    Higashino, H.3
  • 17
    • 0842314637 scopus 로고    scopus 로고
    • Myocardial perfusion defect in acute myocardial infarction on contrast-enhanced helical CT after successful reperfusion therapy: A prognostic value
    • abstr
    • Koyama Y, Matsuoka H, Higasino H, et al: Myocardial perfusion defect in acute myocardial infarction on contrast-enhanced helical CT after successful reperfusion therapy: a prognostic value. Radiology 221:195-196, 2001 (abstr)
    • (2001) Radiology , vol.221 , pp. 195-196
    • Koyama, Y.1    Matsuoka, H.2    Higasino, H.3
  • 18
    • 2442542041 scopus 로고    scopus 로고
    • Assessment of myocardial infarct size by contrast enhanced CT
    • abstr
    • Koyama Y, Matsuoka H, Higasino H, et al: Assessment of myocardial infarct size by contrast enhanced CT. Circulation Suppl II(104):477, 2001 (abstr)
    • (2001) Circulation Suppl II , Issue.104 , pp. 477
    • Koyama, Y.1    Matsuoka, H.2    Higasino, H.3
  • 19
    • 0942273008 scopus 로고    scopus 로고
    • Myocardial perfusion pattern by two-phase contrast CT predicts clinical outcome in patients with acute myocardial infarction after successful reperfusion therapy
    • Koyama Y, Matsuoka H, Higashino H, et al: Myocardial perfusion pattern by two-phase contrast CT predicts clinical outcome in patients with acute myocardial infarction after successful reperfusion therapy. Radiology 225:153, 2002
    • (2002) Radiology , vol.225 , pp. 153
    • Koyama, Y.1    Matsuoka, H.2    Higashino, H.3
  • 20
    • 0035996436 scopus 로고    scopus 로고
    • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • Kachelriess M, Sennst DA, Maxlmoser W, et al: Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys 29:1489-1503, 2002
    • (2002) Med Phys , vol.29 , pp. 1489-1503
    • Kachelriess, M.1    Sennst, D.A.2    Maxlmoser, W.3
  • 21
    • 0013045496 scopus 로고    scopus 로고
    • Assessment of coronary artery aneurysm in Kawasaki disease using multi-detector-row CT
    • abstr
    • Mochizuki T, Higashino H, Koyama Y, et al: Assessment of coronary artery aneurysm in Kawasaki disease using multi-detector-row CT. Circulation Suppl II 104:615, 2001 (abstr)
    • (2001) Circulation Suppl II , vol.104 , pp. 615
    • Mochizuki, T.1    Higashino, H.2    Koyama, Y.3
  • 22
    • 0025940185 scopus 로고
    • Assessment of systolic thickening with thallium-201 ECG-gated single-photon emission computed tomography: A parameter for local left ventricular function
    • Mochizuki T, Murase M, Fujiwara Y, et al: Assessment of systolic thickening with thallium-201 ECG-gated single-photon emission computed tomography: A parameter for local left ventricular function. J Nucl Med 32:1496-1500, 1991
    • (1991) J Nucl Med , vol.32 , pp. 1496-1500
    • Mochizuki, T.1    Murase, M.2    Fujiwara, Y.3
  • 23
    • 0028807605 scopus 로고
    • Automatic quantification of ejection fraction from gated myocardial perfusion SPECT
    • Germano G, Kiat H, Kavanagh PB, et al: Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 36:2138-2147, 1995
    • (1995) J Nucl Med , vol.36 , pp. 2138-2147
    • Germano, G.1    Kiat, H.2    Kavanagh, P.B.3
  • 24
    • 0030912582 scopus 로고    scopus 로고
    • Quantitative LVEF and qualitative regional function from gated thallium- 201 perfusion SPECT
    • Germano G, Erel J, Kiat H, et al: Quantitative LVEF and qualitative regional function from gated thallium-201 perfusion SPECT. J Nucl Med 38:749-754, 1997
    • (1997) J Nucl Med , vol.38 , pp. 749-754
    • Germano, G.1    Erel, J.2    Kiat, H.3
  • 25
    • 0942283828 scopus 로고    scopus 로고
    • Wall motion assessment using multidetector CT: New application of post-processing interactive 2D/3D animated movie of the heart
    • abstr
    • Mochizuki T, Koyama Y, Higashino H, et al: Wall motion assessment using multidetector CT: New application of post-processing interactive 2D/3D animated movie of the heart. Circulation Suppl II 106:1-441, 2002 (abstr)
    • (2002) Circulation Suppl II , vol.106 , pp. 1-441
    • Mochizuki, T.1    Koyama, Y.2    Higashino, H.3
  • 26
    • 0035312512 scopus 로고    scopus 로고
    • Noninvasive detection and evaluation of atherosclerotic coronary plaques with multidetector computed tomography
    • Schroeder S, Kopp AF, Baumbach A, et al: Noninvasive detection and evaluation of atherosclerotic coronary plaques with multidetector computed tomography. J Am Coll Cardiol 37:1430-1435, 2001
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1430-1435
    • Schroeder, S.1    Kopp, A.F.2    Baumbach, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.