-
1
-
-
0028284239
-
Plate and screw fixation for atlanto-axial subluxation
-
Wien
-
Goel A, Laheri V: Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 1994, 129:47-53.
-
(1994)
Acta Neurochir
, vol.129
, pp. 47-53
-
-
Goel, A.1
Laheri, V.2
-
2
-
-
0035890208
-
Posterior C1-C2 fusion with polyaxial screw and rod fixation
-
Harms J, Welcher RP: Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine 2001, 26:2467-2471.
-
(2001)
Spine
, vol.26
, pp. 2467-2471
-
-
Harms, J.1
Welcher, R.P.2
-
3
-
-
0002257576
-
Stable posterior fusion of the atlas and axis by transarticular screw fixation
-
Edited by Kehr P, Werdner PA. New York: Springer-Verlag
-
Magerl F, Seeman PS: Stable posterior fusion of the atlas and axis by transarticular screw fixation. In Cervical Spine. Edited by Kehr P, Werdner PA. New York: Springer-Verlag; 1987:322-327.
-
(1987)
Cervical Spine
, pp. 322-327
-
-
Magerl, F.1
Seeman, P.S.2
-
4
-
-
0025952072
-
Atlanto-axial fusion with transarticular screw fixation
-
Grob D, Jeanneret B, Aebi M, et al.: Atlanto-axial fusion with transarticular screw fixation. J Bone Joint Surg 1991, 73B:972-976.
-
(1991)
J Bone Joint Surg
, vol.73 B
, pp. 972-976
-
-
Grob, D.1
Jeanneret, B.2
Aebi, M.3
-
5
-
-
0038207755
-
Atlantoaxial stabilization: Clinical comparison of posterior cervical wiring technique with transarticular screw fixation
-
Reilly TM, Sasso RC, Hall PV: Atlantoaxial stabilization: clinical comparison of posterior cervical wiring technique with transarticular screw fixation. J Spinal Disord Tech 2003, 16:248-253. In this retrospective review of patients with atlantoaxial arthrodesis for instability, the authors demonstrated that transarticular screw fixation improves the fusion rate over posterior cervical wiring techniques and leads to less postoperative atlantoaxial displacement.
-
(2003)
J Spinal Disord Tech
, vol.16
, pp. 248-253
-
-
Reilly, T.M.1
Sasso, R.C.2
Hall, P.V.3
-
6
-
-
0031896021
-
Vertebral artery injury in C1-C2 transarticular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves
-
Wright NM, Lauryssen C: Vertebral artery injury in C1-C2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. J Neurosurg 1998, 88:634-640.
-
(1998)
J Neurosurg
, vol.88
, pp. 634-640
-
-
Wright, N.M.1
Lauryssen, C.2
-
7
-
-
0029773340
-
The anatomical suitability of the C1-2 complex for transarticular screw fixation
-
Paramore CG, Dickman CA, Sonntag VKH: The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg 1996, 85:221-224.
-
(1996)
J Neurosurg
, vol.85
, pp. 221-224
-
-
Paramore, C.G.1
Dickman, C.A.2
Sonntag, V.K.H.3
-
8
-
-
0030973318
-
Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
-
Madawi AA, Casey AT, Solanki GA, et al.: Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 1997, 86:961-968.
-
(1997)
J Neurosurg
, vol.86
, pp. 961-968
-
-
Madawi, A.A.1
Casey, A.T.2
Solanki, G.A.3
-
9
-
-
0037335825
-
Anatomic study of the axis for surgical planning of transarticular screw fixation
-
Igarashi T, Kikuchi S, Sato K, et al.: Anatomic study of the axis for surgical planning of transarticular screw fixation. Clin Orthop 2003, 408:162-166.
-
(2003)
Clin Orthop
, vol.408
, pp. 162-166
-
-
Igarashi, T.1
Kikuchi, S.2
Sato, K.3
-
10
-
-
0034866583
-
Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement
-
Bloch O, Holly LT, Park J, et al.: Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement. J Neurosurg 2001, 95:74-79.
-
(2001)
J Neurosurg
, vol.95
, pp. 74-79
-
-
Bloch, O.1
Holly, L.T.2
Park, J.3
-
11
-
-
0034667351
-
Modification of C1-C2 transarticular screw fixation by image-guided surgery
-
Weidner A, Wähler M, Chiu ST, et al.: Modification of C1-C2 transarticular screw fixation by image-guided surgery. Spine 2000, 25:2668-2674.
-
(2000)
Spine
, vol.25
, pp. 2668-2674
-
-
Weidner, A.1
Wähler, M.2
Chiu, S.T.3
-
12
-
-
2442633829
-
Point of view
-
Dickman CA: Point of view. Spine 2000, 25:2674.
-
(2000)
Spine
, vol.25
, pp. 2674
-
-
Dickman, C.A.1
-
13
-
-
0042568676
-
Intraoperative spinal navigation
-
Holly LT, Foley KT: Intraoperative spinal navigation. Spine 2003, 28:S54-S61. This excellent review article provides an overview of image-guided surgical technology.
-
(2003)
Spine
, vol.28
-
-
Holly, L.T.1
Foley, K.T.2
-
14
-
-
0037530028
-
The surgical management of type II odontoid fractures: Anterior screw placement versus posterior C1-C2 fusion
-
McGuire RA: The surgical management of type II odontoid fractures: anterior screw placement versus posterior C1-C2 fusion. Curr Opin Orthop 2003, 14:200-203.
-
(2003)
Curr Opin Orthop
, vol.14
, pp. 200-203
-
-
McGuire, R.A.1
-
15
-
-
0034433859
-
Direct anterior screw fixation for recent and remote odontoid fractures
-
Apfelbaum RI, Lonser RR, Veres R, et al.: Direct anterior screw fixation for recent and remote odontoid fractures. J Neurosurg 2000, 93:227-236.
-
(2000)
J Neurosurg
, vol.93
, pp. 227-236
-
-
Apfelbaum, R.I.1
Lonser, R.R.2
Veres, R.3
-
16
-
-
0032100810
-
Anatomic considerations of anterior transarticular screw fixation for atlantoaxial instability
-
Lu J, Ebraheim NA, Yang H, et al.: Anatomic considerations of anterior transarticular screw fixation for atlantoaxial instability. Spine 1998, 23:1229-1235.
-
(1998)
Spine
, vol.23
, pp. 1229-1235
-
-
Lu, J.1
Ebraheim, N.A.2
Yang, H.3
-
17
-
-
0032804668
-
Anterior C1-2 screw fixation and bony fusion through an anterior retropharyngeal approach
-
Vaccaro AR, Lehman AP, Ahlgren BD, et al.: Anterior C1-2 screw fixation and bony fusion through an anterior retropharyngeal approach. Orthopedics 1999, 22:1165-1170.
-
(1999)
Orthopedics
, vol.22
, pp. 1165-1170
-
-
Vaccaro, A.R.1
Lehman, A.P.2
Ahlgren, B.D.3
-
18
-
-
2142698057
-
Anterior instrumentation for traumatic C1-C2 instability
-
Reindl R, Sen M, Aebi M: Anterior instrumentation for traumatic C1-C2 instability. Spine 2003, 28:E329-E333.
-
(2003)
Spine
, vol.28
-
-
Reindl, R.1
Sen, M.2
Aebi, M.3
-
19
-
-
0345181248
-
Screw fixation and fractures of the odontoid process
-
Barbour JR: Screw fixation and fractures of the odontoid process. South Aust Clin 1971, 5:20-28.
-
(1971)
South Aust Clin
, vol.5
, pp. 20-28
-
-
Barbour, J.R.1
-
20
-
-
0031136212
-
Salvage anterior C1-2 screw fixation and arthrodesis through the lateral approach in a patient with symptomatic pseudarthrosis
-
Vaccaro AR, Ring D, Lee RS, et al.: Salvage anterior C1-2 screw fixation and arthrodesis through the lateral approach in a patient with symptomatic pseudarthrosis. Am J Orthop 1997, 26:349-353.
-
(1997)
Am J Orthop
, vol.26
, pp. 349-353
-
-
Vaccaro, A.R.1
Ring, D.2
Lee, R.S.3
-
21
-
-
0036128581
-
Biomechanical comparison of four anterior atlantoaxial plate systems
-
Kandziora F, Pflugmacher R, Ludwig K, et al.: Biomechanical comparison of four anterior atlantoaxial plate systems. J Neurosurg 2002, 96:313-320.
-
(2002)
J Neurosurg
, vol.96
, pp. 313-320
-
-
Kandziora, F.1
Pflugmacher, R.2
Ludwig, K.3
-
22
-
-
0037291782
-
Posterior atlanto-axial fusion with the Olerud cervical fixation system for odontoid fractures and C1-C2 instability in rheumatoid arthritis
-
Cornefjord M, Henriques T, Alemany M, et al.: Posterior atlanto-axial fusion with the Olerud cervical fixation system for odontoid fractures and C1-C2 instability in rheumatoid arthritis. Eur Spine J 2003, 12:91-96.
-
(2003)
Eur Spine J
, vol.12
, pp. 91-96
-
-
Cornefjord, M.1
Henriques, T.2
Alemany, M.3
-
23
-
-
0033982080
-
C1-C2 intra-articular screw fixation for atlantoaxial posterior stabilization
-
Tokuhashi Y, Matsuzaki H, Shirasaki Y, et al.: C1-C2 intra-articular screw fixation for atlantoaxial posterior stabilization. Spine 2000, 25:337-341.
-
(2000)
Spine
, vol.25
, pp. 337-341
-
-
Tokuhashi, Y.1
Matsuzaki, H.2
Shirasaki, Y.3
-
24
-
-
0034669342
-
Translaminar screws in the atlas
-
Floyd T, Grob D: Translaminar screws in the atlas. Spine 2000, 25:2913-2915.
-
(2000)
Spine
, vol.25
, pp. 2913-2915
-
-
Floyd, T.1
Grob, D.2
-
25
-
-
0036954405
-
Atlantoaxial fixation using plate and screw method: A report of 160 treated patients
-
Goel A, Desai KI, Muzumdar DP: Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 2002, 51:1351-1357. This is the largest series in the literature documenting the results of atlantoaxial fusion with C1 lateral mass screws. The authors treated 160 patients during a 14-year period, and successful stabilization was achieved in 157. There were no neurologic, vascular, or infectious complications.
-
(2002)
Neurosurgery
, vol.51
, pp. 1351-1357
-
-
Goel, A.1
Desai, K.I.2
Muzumdar, D.P.3
-
26
-
-
0033836715
-
Quantitative anatomy of the lateral masses of the atlas and axis vertebrae
-
Gupta S, Goel A: Quantitative anatomy of the lateral masses of the atlas and axis vertebrae. Neurol India 2000, 48:120-125.
-
(2000)
Neurol India
, vol.48
, pp. 120-125
-
-
Gupta, S.1
Goel, A.2
-
27
-
-
0032006007
-
The quantitative anatomy of the vertebral artery groove of the atlas and its relation to the posterior atlantoaxial approach
-
Ebraheim NA, Xu R, Ahmad M, et al.: The quantitative anatomy of the vertebral artery groove of the atlas and its relation to the posterior atlantoaxial approach. Spine 1998, 23:320-323.
-
(1998)
Spine
, vol.23
, pp. 320-323
-
-
Ebraheim, N.A.1
Xu, R.2
Ahmad, M.3
-
28
-
-
0037626143
-
Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass
-
Tan M, Wang H, Wang Y, et al.: Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine 2003, 28:888-895. The authors studied the morphometry of 50 dried atlas specimens and used their data to develop a modification of the technique of Harm and Melcher [2] for placing lateral mass screws. The thickness of the posterior arch at the thinnest part of the vertebral artery grew was leas than 4 mm in four cases (8%). This dimension has been reported to be even smaller by other authors (see text).
-
(2003)
Spine
, vol.28
, pp. 888-895
-
-
Tan, M.1
Wang, H.2
Wang, Y.3
-
29
-
-
0037626152
-
Quantitative anatomy of the lateral mass of the atlas
-
Dong Y, Hong MX, Jianyi L, et al.: Quantitative anatomy of the lateral mass of the atlas. Spine 2003, 28:860-863. The dimensions of the atlas were measured on 30 fresh cadaveric specimens. The authors found that adequate space is available for C1 lateral mass screws.
-
(2003)
Spine
, vol.28
, pp. 860-863
-
-
Dong, Y.1
Hong, M.X.2
Jianyi, L.3
-
30
-
-
0037099510
-
Anatomic suitability of the C1-C2 complex for pedicle screw fixation
-
Resnick DK, Lapsiwala S, Trost GR: Anatomic suitability of the C1-C2 complex for pedicle screw fixation. Spine 2002, 27:1494-1498. The dimensions of the C1 lateral mass were adequate in 10 of 10 cases (20 sides) to allow 3.5 mm screws to be placed without impinging on the vertebral artery or the spinal canal. C1-C2 transarticular screws and C2 pedicle screws were anatomically feasible in 94% and 91% of cases, respectively, when CT software was used to plan idealized trajectories and a minimal (0.5 mm) margin for error was accepted.
-
(2002)
Spine
, vol.27
, pp. 1494-1498
-
-
Resnick, D.K.1
Lapsiwala, S.2
Trost, G.R.3
-
31
-
-
2442579305
-
Anatomic relationship of the internal carotid artery to the C1 vertebra: A case report of cervical reconstruction for chordoma and pilot study to assess the risk of screw fixation of the atlas
-
Currier BL, Todd LT, Maus TP, et al.: Anatomic relationship of the internal carotid artery to the C1 vertebra: a case report of cervical reconstruction for chordoma and pilot study to assess the risk of screw fixation of the atlas. Spine 2003, 28:E461-E467. This is case report showed impingement of the ICA by the tip of a well-positioned C1-C2 transarticular screw. Anatomic studies showed that at times the ICA can be within 1 mm of the ideal exit point of a bicortical C1 lateral mass screw or C1-C2 transarticular screw. Contrast-enhanced CT is recommended preoperatively in every case in which a C1-C2 transarticular screw or C1 lateral mass screw may be inserted.
-
(2003)
Spine
, vol.28
-
-
Currier, B.L.1
Todd, L.T.2
Maus, T.P.3
-
32
-
-
2442634163
-
Congenital partial aplasia of the posterior arch of the atlas causing myelopathy: Case report and review of the literature
-
Klimo P Jr: Congenital partial aplasia of the posterior arch of the atlas causing myelopathy: case report and review of the literature. Spine 2003, 28:E224-E228.
-
(2003)
Spine
, vol.28
-
-
Klimo Jr., P.1
-
33
-
-
0026694623
-
Biomechanical evaluation of four different posterior atlantoaxial fixation techniques
-
Grob D, Crisco JJ III, Panjabi MM, et al.: Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine 1992, 17:480-490.
-
(1992)
Spine
, vol.17
, pp. 480-490
-
-
Grob, D.1
Crisco III, J.J.2
Panjabi, M.M.3
-
34
-
-
0029118418
-
Surgical management of atlantoaxial nonunions
-
Dickman CA, Sonntag VKH: Surgical management of atlantoaxial nonunions. J Neurosurg 1995, 83:248-253.
-
(1995)
J Neurosurg
, vol.83
, pp. 248-253
-
-
Dickman, C.A.1
Sonntag, V.K.H.2
-
35
-
-
0031927701
-
Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
-
Dickman CA, Sonntag VXH: Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis. Neurosurgery 1998, 43:275-280.
-
(1998)
Neurosurgery
, vol.43
, pp. 275-280
-
-
Dickman, C.A.1
Sonntag, V.X.H.2
-
36
-
-
0034973263
-
C1-C2 transarticular screw fixation for atlantoaxial instability: A 6-year experience
-
Haid RW Jr, Subach BR, McLaughlin MR, et al.: C1-C2 transarticular screw fixation for atlantoaxial instability: a 6-year experience. Neurosurgery 2001, 49:65-68.
-
(2001)
Neurosurgery
, vol.49
, pp. 65-68
-
-
Haid Jr., R.W.1
Subach, B.R.2
McLaughlin, M.R.3
-
37
-
-
0034669440
-
Biomechanical comparison of five different atlantoaxial posterior fixation techniques
-
Henriques T, Cunningham BW, Olerud C, et al.: Biomechanical comparison of five different atlantoaxial posterior fixation techniques. Spine 2000, 25:2877-2883.
-
(2000)
Spine
, vol.25
, pp. 2877-2883
-
-
Henriques, T.1
Cunningham, B.W.2
Olerud, C.3
-
38
-
-
0033193322
-
Biomechanical study of atlantoaxial arthrodesis: Transarticular screw fixation versus modified Brooks posterior wiring
-
Mitchell TC, Sadasivan KK, Ogden AL, et al.: Biomechanical study of atlantoaxial arthrodesis: transarticular screw fixation versus modified Brooks posterior wiring. J Orthop Trauma 1999, 13:483-489.
-
(1999)
J Orthop Trauma
, vol.13
, pp. 483-489
-
-
Mitchell, T.C.1
Sadasivan, K.K.2
Ogden, A.L.3
-
39
-
-
0032530291
-
Biomechanical comparison of C1-C2 posterior fixation: Cable, graft, and screw combinations
-
Naderi S, Crawford NR, Song GS, et al.: Biomechanical comparison of C1-C2 posterior fixation: cable, graft, and screw combinations. Spine 1998, 23:1946-1955.
-
(1998)
Spine
, vol.23
, pp. 1946-1955
-
-
Naderi, S.1
Crawford, N.R.2
Song, G.S.3
-
40
-
-
0037112085
-
Biomechanical testing of posterior atlantoaxial fixation techniques
-
Melcher RP, Puttlitz CM, Kleinstueck FS, et al.: Biomechanical testing of posterior atlantoaxial fixation techniques. Spine 2002, 27:2435-2440. The authors compared a construct of polyaxial C1 lateral mass screws and C2 pedicle screws secured to bilateral 3-mm rods with a construct of two transarticular screws and a Gallie posterior wire graft. There was no difference in stability between the two fixation techniques, and both were more stable in lateral bending and axial rotation than a Gallie construct without screws.
-
(2002)
Spine
, vol.27
, pp. 2435-2440
-
-
Melcher, R.P.1
Puttlitz, C.M.2
Kleinstueck, F.S.3
-
41
-
-
0037102598
-
Posterior atlantoaxial fixation: Biomechanical in vitro comparison of six different techniques
-
Richter M, Schmidt R, Claes L, et al.: Posterior atlantoaxial fixation: biomechanical in vitro comparison of six different techniques. Spine 2002, 27:1724-1732.
-
(2002)
Spine
, vol.27
, pp. 1724-1732
-
-
Richter, M.1
Schmidt, R.2
Claes, L.3
-
42
-
-
0030055004
-
Biomechanical characteristics of C1-C2 cable fixations
-
Dickman CA, Crawford NR, Paramore CG: Biomechanical characteristics of C1-C2 cable fixations. J Neurosurg 1996, 85:316-322.
-
(1996)
J Neurosurg
, vol.85
, pp. 316-322
-
-
Dickman, C.A.1
Crawford, N.R.2
Paramore, C.G.3
-
43
-
-
0036481526
-
C1-C2 pedicle screw fixation with rigid cantilever beam construct: Case report and technical note
-
Resnick DK, Benzel EC: C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery 2002, 50:426-428.
-
(2002)
Neurosurgery
, vol.50
, pp. 426-428
-
-
Resnick, D.K.1
Benzel, E.C.2
-
44
-
-
0042209861
-
C1 lateral mass screws: Surgical nuances
-
Fiore AJ, Mummaneni PV, Haid RW, et al.: C1 lateral mass screws: surgical nuances. Tech Orthop 2003, 17:272-277. The authors describe the surgical technique for placing C1 lateral mass screws as well as alternative techniques for C2 screw fixation. They also describe the anatomic distinction between the C2 pars interarticularis and pedicle.
-
(2003)
Tech Orthop
, vol.17
, pp. 272-277
-
-
Fiore, A.J.1
Mummaneni, P.V.2
Haid, R.W.3
|