메뉴 건너뛰기




Volumn 28, Issue 2-4, 2004, Pages 299-308

Stability of lightweight structural sandwich panels exposed to fire

Author keywords

Ceilings; Cold stores; Collapse; Fire engineering; Fire resistance; Fire scenarios; Sandwich panel; Stability; Walls

Indexed keywords

BUILDING CODES; CEILINGS; ELECTRIC INSULATION; FIRE HAZARDS; FIRE PROTECTION; FIRE RESISTANCE; FIRES; SANDWICH STRUCTURES; STRUCTURAL DESIGN; THERMAL INSULATION; WALLS (STRUCTURAL PARTITIONS); WEIGHT CONTROL;

EID: 2442471752     PISSN: 03080501     EISSN: None     Source Type: Journal    
DOI: 10.1002/fam.851     Document Type: Article
Times cited : (10)

References (11)
  • 2
    • 2442632296 scopus 로고    scopus 로고
    • Special architectural applications
    • Davies JM (ed.); Blackwell Science: Oxford
    • Davies JM (ed.). Special architectural applications. In Lightweight Sandwich Construction. Blackwell Science: Oxford, 2001.
    • (2001) Lightweight Sandwich Construction
  • 3
    • 2442470773 scopus 로고    scopus 로고
    • When are sandwich panels safe in fire? - Part 1 An overview
    • July
    • Cooke GME. When are sandwich panels safe in fire? - Part 1 An overview. Fire Engineers Journal July 1998; 37-41.
    • (1998) Fire Engineers Journal , pp. 37-41
    • Cooke, G.M.E.1
  • 4
    • 2442632822 scopus 로고    scopus 로고
    • When are sandwich panels safe in fire? - Part 2 avoiding collapse
    • Sept
    • Cooke GME. When are sandwich panels safe in fire? - Part 2 Avoiding collapse. Fire Engineers Journal Sept 1998; 25-33.
    • (1998) Fire Engineers Journal , pp. 25-33
    • Cooke, G.M.E.1
  • 5
    • 2442635005 scopus 로고    scopus 로고
    • When are sandwich panels safe in fire? - Part 3 fire scenarios, fire tests and checklist
    • January
    • Cooke GME. When are sandwich panels safe in fire? - Part 3 Fire scenarios, fire tests and checklist. Fire Engineers Journal January 1999; 18-25.
    • (1999) Fire Engineers Journal , pp. 18-25
    • Cooke, G.M.E.1
  • 6
    • 2442633577 scopus 로고    scopus 로고
    • The behaviour of sandwich panels exposed to fire
    • July
    • Cooke GME. The behaviour of sandwich panels exposed to fire. Building Engineer July 1987; 14-29.
    • (1997) Building Engineer , pp. 14-29
    • Cooke, G.M.E.1
  • 9
    • 1242291492 scopus 로고    scopus 로고
    • Davies JM (ed.); Blackwell Science: Oxford
    • Davies JM (ed.). Lightweight Sandwich Construction. Blackwell Science: Oxford, 2001.
    • (2001) Lightweight Sandwich Construction


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.